In order to size a drained portion of the relief vent, ei: (2 lavs draining into the relief vent) The relief vent should be: a) A minimum size of 2" b) Sized by the wet vent table c) Sized by the individual vent table d) One size smaller than the circuit vent e) Sized by table 2.5.8.3. -...

[Show more]

Preview 2 out of 13  pages

  • November 20, 2024
  • 13
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Red Seal Plumber Alberta Canada
  • Red Seal Plumber Alberta Canada
avatar-seller
PatrickKaylian
Red Seal Plumber Alberta Canada
In order to size a drained portion of the relief vent, ei: (2 lavs draining into the relief vent)
The relief vent should be:
a)
A minimum size of 2"
b)
Sized by the wet vent table
c)
Sized by the individual vent table
d)
One size smaller than the circuit vent
e)
Sized by table 2.5.8.3. - ✔️✔️b

If four shower heads are installed along a wall, what would the minimum measurement
be between the two outermost heads? - ✔️✔️2.25m

A 3" drainage pipe (1/4" per ft) suspended from a ceiling inside a building at it most
upstream end is 7.5" from the ceiling to the center of the pipe. What will the
measurement be from the ceiling to the center of the pipe if it travels 26 feet
horizontally, has an 8 foot horizontal offset then continues another 37 feet. - ✔️✔️25.2"

What is the minimum length of a trap arm? - ✔️✔️2 pipe diameters

A branch with 34 fixture units discharges into a sewage sump. What is the minimum
size vent required for the sump? - ✔️✔️3"

A building's roof measuring 90m by 50m would require how many flow controlled roof
drains? - ✔️✔️5

What force would be exerted on the gate of a closed 6" gate valve if the water pressure
acting on it measured 46 Psig. - ✔️✔️1300

Asbestos cement pipe installed below a 60 mm thick concrete floor must be at least how
deep? - ✔️✔️600mm

The discharge from a sump pump shall have the following fittings installed in order, in
the direction of flow: - ✔️✔️union, check valve, shut-off valve

When a well pump turns on as soon as a faucet is used the most likely problem is: -
✔️✔️water logged pressure tank

, A gear pump is a positive displacement pump and must be installed with a: -
✔️✔️pressure relief valve

What type of trap is not permitted in a drainage system: - ✔️✔️bell trap

Where is the jet located in a deep well? - ✔️✔️above the foot valve

How would you increase the length of flush on a flushometer? - ✔️✔️turn regulating
screw counter clockwise

Radon piping in order - ✔️✔️MFG manometer, fan and gooseneck

Temporary Platform Scaffolding erected must have toeboards install when the
scaffolding is more than m above the ground. - ✔️✔️3.5 m

Horizontally run ¾" type M copper pipe must be supported every: - ✔️✔️2.5 meters

Water that is determined to have a PH of 5.5 would be considered: - ✔️✔️mildly acidic

Dielectric unions are used to: - ✔️✔️prevent corrosion

When installing glass piping; if one end needs to be field cut, the ends should be joined:
- ✔️✔️bead to plain


Six equally spaced lav's are to be installed along a wall that is 530 cm long and will be
vented with dual vents. Determine the center to center distance between vents if the
fixtures are each 51 cm wide. - ✔️✔️177cm


The absorption rate of a septic field is determined by: - ✔️✔️percolation test

Determine the amount of expansion that will occur when a 15m ABS pipe has a
temperature change of 40ºC. EXPANSION RATE OF ABS is .000099 in Celsius -
✔️✔️59.4 mm

Which backflow preventer is not a testable device? - ✔️✔️DCAP

A properly cut thread on black iron pipe should allow how many hand turns with a
fitting? - ✔️✔️4 1/2

A well with a water tight casing requires a minimum standoff distance from a septic
system of: - ✔️✔️15m

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller PatrickKaylian. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $8.29. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

71498 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$8.29
  • (0)
  Add to cart