100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

IRC 2025 Electrical Inspector Examination Study Guide Questions and Answers.

Rating
-
Sold
-
Pages
21
Grade
A+
Uploaded on
28-01-2025
Written in
2024/2025

IRC2025ElectricalInspectorExaminationStudyGuideQuestions andAnswers. Cords that supply swimming pool equipment shall have a copper equipment grounding conductor not smaller than No. ______________ AWG. - Correct Answer 12 AWG. 2015 IRC Section E4202.2 Flexible cords, Item 1 Receptacles shall be installed so that no point along the floor line in any wall space is more than _________ feet, measured horizontally, from an outlet in that space. - Correct Answer 6 Feet. This is the rule 6/12 rule: 6 feet from any door opening and every 12 feet after that, measure along the wall. 2015 IRC Section E3901.2.1 Spacing. Receptacles installed on 15- and 20-ampere-rated branch circuits shall be of the ___________ type. - Co

Show more Read less
Institution
IRC 2025 Electrical Inspector
Course
IRC 2025 Electrical Inspector










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
IRC 2025 Electrical Inspector
Course
IRC 2025 Electrical Inspector

Document information

Uploaded on
January 28, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

IRC 2025 Electrical Inspector Examination Study Guide Questions
and Answers.
Cords that supply swimming pool equipment shall have a copper equipment grounding
conductor not smaller than No. ______________ AWG. - Correct Answer 12 AWG.

2015 IRC Section E4202.2 Flexible cords, Item 1

Receptacles shall be installed so that no point along the floor line in any wall space is more
than _________ feet, measured horizontally, from an outlet in that space. - Correct Answer
6 Feet.

This is the rule 6/12 rule: 6 feet from any door opening and every 12 feet after that,
measure along the wall.

2015 IRC Section E3901.2.1 Spacing.

Receptacles installed on 15- and 20-ampere-rated branch circuits shall be of the
___________ type. - Correct Answer grounding.

2015 IRC Section E4002.2 Grounding type.

In clothes closets, surface-mounted incandescent luminaires shall have _________
inches minimum clearance from the nearest point of storage space. - Correct Answer 12
inches.

This is measured horizontally and changes to 6 inches for surface mounted/recessed
fluorescent and recessed incandescent fixtures.

2015 IRC Section E4003.12 Luminaries in clothes closets, Item 1

Conductors in NM cable assemblies shall be rated at _________ Celsius. - Correct
Answer 90 degrees Celsius.

The 90 degree Celsius rating shall be permitted to be used for ampacity correction and
adjustment purpose provided that the final corrected or adjusted ampacity does not
exceed that for a 60 degree Celsius rated conductor.

2015 IRC Section E3705.4.4 Conductors of Type NM cable.

In calculating box fill, each No. 12 AWG conductor shall require ______________ cubic
inches free space within the box. - Correct Answer 2.25 cubic inches.

2015 IRC Table E3905.12.2.1 Volume Allowance Required Per Conductor.

,Except for Type IC luminaires, thermal insulation shall not be installed above a recessed
luminaire or within _______________ inches of the recessed luminaire's enclosure. -
Correct Answer 3 inches.

Exception for Type IC luminaires.


2015 IRC Section E4004.9 Recessed luminaire installation.

Branch circuit ratings for space-heating and water-heating appliances shall be considered
____________ loads. - Correct Answer continuous.

2015 IRC Section E3702.10 Branch circuits serving heating loads.

A minimum of ____________ 20-ampere-rated branch circuits shall be provided to serve
all wall and floor receptacle outlets located in the kitchen, pantry, breakfast area, dining
area or similar area of a dwelling. - Correct Answer Two.


2015 IRC Section E3703.2 Kitchen and dining area receptacles.

A minimum of one ____________-ampere-rated branch circuit shall be provided for
receptacles located in the laundry area and shall serve only receptacle outlets in the
laundry area. - Correct Answer 20 ampere.

Receptacles for appliances like the washer shall be located within 6 feet of the appliance
location. See Section E3901.5

2015 IRC Section E3703.3 Laundry circuit.

Bonding shall be provided where necessary to ensure electrical ______________. -
Correct Answer continuity.

and the capacity to conduct safely any fault current likely to be imposed.

2015 IRC Section E3609.1 General

Switches shall not be more than _________________ feet _________________ inches
above the floor or working platform when the switch is in its highest position. - Correct
Answer 6 feet

7 inches

Also applies to circuit breakers used as switches.

2015 IRC Section E4001.6 Access.

, the rating of any one cord-and-plug- connected utilization equipment shall not exceed
________ percent of the branch-circuit ampere rating. - Correct Answer 80 percent.


2015 IRC Section E3702.3 Fifteen-and 20-ampere branch circuits.

All mechanical elements used to terminate a grounding electrode conductor or bonding
jumper to the grounding electrodes shall be __________________. - Correct Answer
accessible.

When not buried or concrete encased.

2015 IRC Section E3611.2 Accessibility.

Interior metal water piping located more than _________ feet from the point of entrance to
the building shall not be used as part of the grounding electrode system. - Correct Answer
5 feet.


2015 IRC Section E3608.1.1.1 Interior metal water piping.

Electrical panelboards and overcurrent devices shall not be located in
_______________________________. - Correct Answer clothes closets, bathrooms or
over the steps of a stairway.


2015 IRC Section E3405.5 Location of working spaces and equipment.

Overhead service-drop conductors shall have a vertical clearance of not less than
__________ feet above the roof surface. - Correct Answer 8 feet.

Review all of the exceptions in this section.

2015 IRC Section E3604.2.1 Above roofs.

Electrical services within the scope of the IRC are limited to ____________-volt, 0-to
_______________ - ampere, single-phase systems. - Correct Answer 120/240

400

2015 IRC Section E3401.2 Scope

Recessed incandescent fixtures shall have _____________ protection. - Correct Answer
Thermal.
$18.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
LECTME
3.5
(2)

Get to know the seller

Seller avatar
LECTME Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
7
Member since
2 year
Number of followers
4
Documents
2714
Last sold
1 year ago
Assignments, Case Studies, Research, Essay writing service, Questions and Answers, Discussions etc. for students who want to see results twice as fast.

I have done papers of various topics and complexities. I am punctual and always submit work on-deadline. I write engaging and informative content on all subjects. Send me your research papers, case studies, psychology papers, etc, and I’ll do them to the best of my abilities. Writing is my passion when it comes to academic work. I’ve got a good sense of structure and enjoy finding interesting ways to deliver information in any given paper. I love impressing clients with my work, and I am very punctual about deadlines. Send me your assignment and I’ll take it to the next level. I strive for my content to be of the highest quality. Your wishes come first— send me your requirements and I’ll make a piece of work with fresh ideas, consistent structure, and following the academic formatting rules. For every student you refer to me with an order that is completed and paid transparently, I will do one assignment for you, free of charge!!!!!!!!!!!!

Read more Read less
3.5

2 reviews

5
0
4
1
3
1
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions