EPA 608 Type 3 Certifications Questions & Answers!!
- Exam (elaborations) • 16 pages • 2023
- Available in package deal
-
- $10.49
- + learn more
When using recovery or recycling equipment manufactured or imported on or after Nov 15, 1993, the required level of evacuation for low pressure equipment is _____ Hg absolute: 
 
30mm 
25mm 
15mm 
20mm - ANSWER 25mm 
 
The EPA requires that all commercial and industrial process refrigeration systems with more than 50lb of refrigerant be repaired when the annual leak rate exceeds ______: 
 
35% 
15% 
30% 
25% - ANSWER 35% 
 
Open-drive compressors are typically _____ compressors 
 
centrifugal 
r...
-
EPA 608 - Type III Correct Questions & Answers(RATED A+)
- Exam (elaborations) • 16 pages • 2023
- Available in package deal
-
- $11.99
- + learn more
technicians maintaining, servicing, repairing, or disposing of low-pressure appliances must be certified as: - ANSWER Type III or Universal Technician 
 
the owner &/or operator of the equipment is responsible for keeping: - ANSWER records including: leak inspections & any completed leak repair verification tests 
 
it's the _______ &/or ___________ responsibility to obtain service records from the servicing company doing any work on an appliancem - ANSWER owner &/ or operator 
 
as of 11/14/94...
-
EPA 608 Type III Correct Questions & Answers 2023-2024 (SCORED A+)
- Exam (elaborations) • 18 pages • 2023
- Available in package deal
-
- $11.99
- + learn more
Identify the pressure corresponding to 32 degrees F for R-123: ________. 
 
a) 23 inches of Hg vacuum 
b) 20 inches of Hg vacuum 
c) 17 inches of Hg vacuum 
d) 11 inches of Hg vacuum - ANSWER b) 20 inches of Hg vacuum 
 
A hydrostatic tube test kit is used to: _________. 
 
a) blow all water from the tubes 
b) remove any water from the machine 
c) vent refrigerant 
d) determine if a tube leaks - ANSWER d) determine if a tube leaks 
 
Excessive running of a purge system on a low pressure chiller ...
-
EPA 608 Type III Correct Questions & Answers(Rated A)
- Exam (elaborations) • 5 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low pressure chiller is: - ANSWER C) 10 psig. 
 
A charged low pressure refrigeration system can be efficiently leak checked by: - ANSWER D) raising system pressure by heating with circulated hot water or heating blankets. 
 
The existence of air in a low pressure system, causes __________. - ANSWER C) high head pressure. 
 
Which safety precaution should be adhered to for low pr...
-
EPA 608 ESCO--Type 1......Online Questions & Answers 100% Correct!
- Exam (elaborations) • 1 pages • 2024
- Available in package deal
-
- $15.49
- + learn more
If regulations change after the technician becomes certified.........? - ANSWERThe technician is responsible for complying with any changes to the regulations 
 
System-dependent recovery methods may only be used on appliances containing......? - ANSWER15 pounds of refrigerant or less 
 
Which HC refrigerant is allowed for use in New Domestic Small Appliances......? - ANSWERR-600A 
 
When filling a charging cylinder with a regulated refrigerant.......? - ANSWERThe refrigerant vapor that is vente...
Get paid weekly? You can!
-
EPA 608 Type 3 Correct Questions & Answers(Rated A)
- Exam (elaborations) • 10 pages • 2023
- Available in package deal
-
- $11.99
- + learn more
On low pressure chillers, moisture typically enters the refrigerant system through - ANSWER air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ANSWER 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - ANSWER ... 
 
A hydrostatic tube test kit is used to: - ANSWER determine if a tube leaks 
 
Commercial and industrial process refrigeration systems must be repaired wh...
-
EPA 608 Type III Exam Correct 100% Correct!!
- Exam (elaborations) • 4 pages • 2023
- Available in package deal
-
- $11.49
- + learn more
Before recovering refrigerant from a chiller suspected of having tube leaks,... - ANSWER ...drain the water sides of the evaporator and condenser. Draining the water sides helps to avoid the introduction of additional water into the system cause by the evacuation process and to prevent the water from freezing as the refrigerant evaporates during recovery. 
 
How can you pressurize a low-pressure chiller to make a non-major repair? - ANSWER Warm up the system. 
 
Under EPA regulations, you may wa...
-
EPA 608 Type III Sample Test Questions & Answers
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
Where do leaks commonly occur in low pressure systems? 
a. Evaporator 
b. Condenser 
c. Purge unit 
d. Gaskets or fittings - ANSWER d. Gaskets or fittings 
 
Where do leaks commonly occur in open-drive type compressor systems? 
a. Evaporator 
b. Condenser 
c. Shaft seal 
d. Cooling tower - ANSWER c. Shaft seal 
 
Does refrigerant go out of the system in low pressure systems or does air and 
moisture go in? 
a. Refrigerant escapes through low pressure leaks. 
b. Air and moisture enter the refrige...
-
EPA 608: Type III Correct 100% Correct!!
- Exam (elaborations) • 5 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
Techs maintaining, servicing, repairing, or disposing of low pressure appliances must be certified as? - ANSWER Type III or universal technician 
 
As of what date was the sale of CFCs and HCFCs restricted to certified techs? - ANSWER Nov 14, 1994 
 
Who is responsible to comply with changes in section 608? - ANSWER The technician 
 
Because low pressure systems operate in a vacuum , where will leaks occur? - ANSWER Gaskets or fittings (allow air or moisture into the system? 
 
What is the most ...
-
EPA 608 Type III| QUESTIONS| Correct Answers!
- Exam (elaborations) • 3 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
a Type III Technician or Universal Technician are certified to do what? - ANSWER Maintain, service, repair, or dispose of low-pressure appliances. 
 
Most low pressure appliances are used for what? - ANSWER Most low pressure appliances are used for comfort cooling and are subject to lower allowable leak rate. 
 
The owner and/or operator of the equipment is responsible for what? - ANSWER for keeping records of all leaking inspections and any completed leak repair verification tests. It is their ...
That summary you just bought made someone very happy. Also get paid weekly? Sell your study resources on Stuvia! Discover all about earning on Stuvia