Nec nfpa 70 - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Nec nfpa 70? On this page you'll find 49 study documents about Nec nfpa 70.
Page 2 out of 49 results
Sort by
-
NETA level 2 exam final exam 2024 updated
- Exam (elaborations) • 22 pages • 2024
-
- $15.49
- + learn more
NETA level 2 exam final exam 2024 
updated 
What is the preferred method of performing primary-injection testing on a low voltage 
circuit breaker with ground fault protection? - CORRECT ANSWER-Use of the 
manufacturer's test kit or rewiring the neutral CT input is the preferred method of 
primary-injection testing on a low voltage circuit breaker with ground fault protection, 
otherwise two poles can be connected in series to provide balanced secondary currents 
to the trip unit. 
At wha...
-
NFPA 70 NEC 2020 Exam Questions with Answers (1)
- Exam (elaborations) • 6 pages • 2024
-
- $13.49
- + learn more
NFPA 70 NEC 2020 Exam Questions with Answers (1) 
 
 
Article 90 - Answer-Intro 
 
Article 100 - Answer-Definitions 
 
Article 110.26 - Answer-Working Space 
 
Article 210 - Answer-Branch Circuits 
 
Article 210.8 - Answer-GFCI Protection 
 
Article 210.12 - Answer-AFCI Protection 
 
Table 210.24 - Answer-Branch Circuit Summary 
 
Article 210.52 - Answer-Dwelling Receptacle Outlets 
 
Article 215 - Answer-Feeders 
 
Article 220 - Answer-Branch, Feeder, Service Calculations 
 
Table 220.55 - Answ...
-
Master Electrician PREP QUESTIONS WITH ANSWERS 2024/2025
- Exam (elaborations) • 7 pages • 2023
- Available in package deal
-
- $12.99
- + learn more
Master Electrician PREP 
QUESTIONS WITH ANSWERS 
where passing through a floor, cables shall be protected from 
physical damage at what distance above the floor? 
a. 10 inches 
b. 6 inches 
c. 12 inches 
d. 8 inches - ANSWER 6 inches 
NFPA 70 : NEC 2011 : 334.15.B 
A company has an electrical contractors license. The Master 
Electrician decides to leave the company. How many days does 
the company (licensee) have to notify the division? 
a. 30 days 
b. 10 days 
c. 20 days 
d. 5 days - ANSWER...
-
ELMC Master Electrician Code 251-275 Questions With Complete Solutions
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
What is the MAXIMUM allowable voltage that conductors within electrical nonmetallic tubing (ENT) may carry? 
a. 1000 
b. 2000 
c. 600 
d. 240 correct answer: 1000 
 
NFPA 70 : NEC 2017 : 300.2, 362.1 
 
Unprotected cable is to be installed in holes bored in wood studs. Each hole shall be bored so that the edge of the hole is what minimum distance for the edge of the stud? 
a. 2 
b. 1 
c. 1-1/2 
d. 1-1/4 correct answer: 1-1/4 
 
NFPA 70 : NEC 2011 : 300.4.A.1 
 
Given: Only the following type T...
-
NEC NFPA 70 Exam Questions and Answers
- Exam (elaborations) • 3 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
NEC NFPA 70 Exam Questions and Answers 
arc-fault circuit interruptor (AFCI) -Answer-A(n) ____ is a device intended to provide protection 
from the effects of arc faults by recognizing characteristics unique to arcing 
fitting -Answer-A(n) ____ is an accessory, such as a locknut or bushing, whose function is 
primarily mechanical, rather than electrical, in nature. 
the same panelboard or similar distribution equipment -Answer-All conductors of a multiwire 
branch circuit must originate from ___...
As you read this, a fellow student has made another $4.70
-
NICET 1 Rev 01 Written Exam Questions & Answers.
- Exam (elaborations) • 80 pages • 2024
-
- $12.49
- + learn more
NICET 1 Rev 01 Written Exam Questions & Answers. 
 
 
"A. As Built Drawings Hint: NFPA 72 - 14.6.1.1 - KEY: records sub testing, inspection and maintenance 
NOTE: As built drawings are drawings of record per A.7.7.2.3 - CORRECT ANSWER " "After acceptance testing, what type of drawings are required to be presented to the building owner? 
A. As Built Drawings 
B. Contract Drawings 
C. Point-To-Point Diagrams 
D. Manufacturer's Drawings 
 
" 
"C. 3 Hint: NFPA 72 - 10.6.11.6.3 - KEY: fuel - CO...
-
NETA LEVEL II EXAM QUESTIONS CORRECTLY ANSWERED 2024.
- Exam (elaborations) • 28 pages • 2024
-
- $9.99
- + learn more
NETA LEVEL II EXAM QUESTIONS CORRECTLY ANSWERED 2024. 
 
 
What is the preferred method of performing primary-injection testing on a low voltage circuit breaker with ground fault protection? 
Use of the manufacturer's test kit or rewiring the neutral CT input is the preferred method of primary-injection testing on a low voltage circuit breaker with ground fault protection, otherwise two poles can be connected in series to provide balanced secondary currents to the trip unit. 
At what current le...
-
NICET 1 Questions and Answers (2022/2023) (Scored A)
- Exam (elaborations) • 89 pages • 2023
- Available in package deal
-
- $11.49
- + learn more
NICET 1 Questions and Answers (2022/2023) (Scored A) 
If combination audible/visible appliances are installed, the location of the installed appliance shall be determined by the requirements of 
a. the audible appliance 
b. the visible appliance 
c. the NEC 
d. the AHJ b. the visible appliance 
What is the maximum number of 12 gauge THHN wires that can be installed in 1-inch EMT? 
a. 26 
b. 35 
c. 19 
d. 32 a. 26 
Two resistors are connected in parallel. R1= 300 Ohms, R2= 300 Ohms. What is their...
-
RCDD CHPT 1 CODES AND STANDARDS EXAM QUESTIONS AND ANSWERS
- Exam (elaborations) • 12 pages • 2023
- Available in package deal
-
- $15.99
- + learn more
1. Local authority having Jurisdiction (AHJ) 
enforces the codes and standards 
 
 
 
2. Purpose of codes 
safeguarding of persons and property, quality of construction 
 
 
 
3. Codes 
when adopted by AHJ are law 
 
 
 
4. Local AHJ take presedent 
over the most restrictive code 
 
 
 
asked EIA to undertake the standards for telecommunication cabling 
5. CCIA 
 
 
 
6. EIA 
Electronic industries Alliance 
 
 
 
7. TIA/EIA 
accredited thru the American National Standards Institute (ANSI) 
 
 
 ...
-
NETA level 2 exam final exam 2024 updated
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $15.99
- + learn more
NETA level 2 exam final exam 2024 
updated 
What is the preferred method of performing primary-injection testing on a low voltage 
circuit breaker with ground fault protection? - CORRECT ANSWER-Use of the 
manufacturer's test kit or rewiring the neutral CT input is the preferred method of 
primary-injection testing on a low voltage circuit breaker with ground fault protection, 
otherwise two poles can be connected in series to provide balanced secondary currents 
to the trip unit. 
At wha...
How did he do that? By selling his study resources on Stuvia. Try it yourself! Discover all about earning on Stuvia