Oil burner answers - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Oil burner answers? On this page you'll find 1009 study documents about Oil burner answers.
Page 2 out of 1.009 results
Sort by
-
COF P-98 PRACTISE EXAM / 100 QUESTIONS AND VERIFIED ANSWERS 2023/2024 / ALL CORRECT.
- Exam (elaborations) • 22 pages • 2023
-
- $9.99
- 1x sold
- + learn more
COF P-98 PRACTISE 
EXAM / 100 QUESTIONS 
AND VERIFIED ANSWERS 
2023/2024 / ALL CORRECT. 
COF P-98 Practice test 
2023 
1. The person supervising the Fuel-Oil transfer in the building from one floor to 
another must hold what type of certificate of fitness: P-98 Certificate of Fitness 
2. In designing the fuel-Oil transfer system, such as diesel #2 oil from the 
lowest floor to the floor above the tank level, the following factors must be 
considered:: - Maximum inlet suction an flow-rate 
- Desi...
-
Massachusetts Oil burner Practice Exam Questions and Answers 100% Pass
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $11.49
- 1x sold
- + learn more
Massachusetts Oil burner Practice Exam 
Questions and Answers 100% Pass 
The cross connection between two supply tanks shall not exceed? - Correct Answer ️️ 
-660 gallons 
When is an automatic draft control not required? - Correct Answer ️️ -When the 
equipment is designed to control the draft. 
Combustion performance testing can indicate: - Correct Answer ️️ -Improper air oil 
mixture, too much combustion air, and low pump pressure. 
If a second oil-burning appliance is installed in...
-
COF P-98 Practice test Exam Questions & Answers 100% Correct!
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $12.99
- 1x sold
- + learn more
The person supervising the Fuel-Oil transfer in the building from one floor to another must hold what type of certificate of fitness - ANSWERSP-98 Certificate of Fitness 
 
In designing the fuel-Oil transfer system, such as diesel #2 oil from the lowest floor to the floor above the tank level, the following factors must be considered: - ANSWERS- Maximum inlet suction an flow-rate 
- Design of oil piping system and discharge pressure 
- Proper control strategy 
 
_______________________ fires ar...
-
P-99 / Low PSI Oil Burner Operator Questions With 100%Verified Answers A+GRADED
- Exam (elaborations) • 9 pages • 2024
-
- $8.99
- 1x sold
- + learn more
P-99 / Low PSI Oil Burner Operator Questions With 100%Verified Answers A+GRADED 
 
All heating, combustion, and cooking equipment shall be provided with insulation or the building construction shall be fire protected, so that during operation the surface of combustible construction materials will not be raised to a temperature higher than ____. - correct answer...170 ̊ F 
 
Acceptance tests: Boilers shall not be placed in operation upon completion of construction until they have been ____ and a...
-
Mass oil burner exam questions with correct answers 100%
- Exam (elaborations) • 4 pages • 2024
- Available in package deal
-
- $15.49
- 1x sold
- + learn more
Mass oil burner exam questions with correct answers
Too much month left at the end of the money?
-
Oil Burner License Exam 2023 Questions and Answers
- Exam (elaborations) • 18 pages • 2023
- Available in package deal
-
- $12.49
- 4x sold
- + learn more
What is the first thing a tech should do when arriving at a no combustion call? - Answer- Ask how many times the customer reset the unit. 
 
What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. 
-Install a quality oil filter. 
-Cut the suction line 10" above the tank outlet to prevent sludge. 
 
Hot water and steam valves are interchangeable. - Answer- False 
 
When in the presence of a flame, a cad cell normally reads.. - Answe...
-
Oil Burner License Exam Questions and Answers (Already Graded A+)
- Exam (elaborations) • 43 pages • 2024
- Available in package deal
-
- $16.99
- + learn more
Oil Burner License Exam Questions and Answers (Already Graded A+)Oil Burner License Exam Questions and Answers (Already Graded A+)Oil Burner License Exam Questions and Answers (Already Graded A+)Oil Burner License Exam Questions and Answers (Already Graded A+) 
What is the first thing a tech should do when arriving at a no combustion call? - ANSWER-Ask how many times the customer reset the unit. 
 
What is the best long term solution for preventing a clogged nozzle? - ANSWER--Remove any undergro...
-
Oil Burner License Questions And Answers With Verified Solutions 2024 Tests
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Oil Burner License Questions And Answers With Verified Solutions 2024 Tests 
 
Oil Burner License Questions And Answers With Verified Solutions 2024 Tests
-
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
- Exam (elaborations) • 20 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove 
any underground storage tanks. 
-Install a quality oil filter. 
-Cut the suction line 10" above the tank outlet to prevent sludge. 
Hot water and steam valves are interchangeable. - Answer- False 
When in the presence of a flame, a cad cell normally reads.. - Answer- 300-1000 ohms 
If a pump is used to bring oil to a l...
-
Mass Oil Burner Exam Bundle Pack:::Questions and Answers | 100% Correct
- Package deal • 4 items • 2024
-
- $34.46
- 1x sold
- + learn more
Mass Oil Burner Exam Bundle Pack:::Questions and Answers | 100% Correct
$6.50 for your textbook summary multiplied by 100 fellow students... Do the math: that's a lot of money! Don't be a thief of your own wallet and start uploading yours now. Discover all about earning on Stuvia