ABSA 5th Class Questions and Answers
- Exam (elaborations) • 31 pages • 2024
- Available in package deal
-
- $9.69
- + learn more
Where are the return openings located regarding air distribution systems? - Answer-Return air openings 
are located on inner walls. 
The minimum temperature of the water used in a hydrostatic test of a boiler cannot be less than what 
temperature? - Answer-20 degrees Celsius 
Which of the following are causes of pressure explosions? 
1. effects of corrosion 
2. weak pilot flame 
3. stressed material due to heating too quickly 
4. insufficient purge 
5. scale and sludge build-up - Answer-1, 3, 5 ...
-
FDNY COF P-98 Exam With 100% Correct Answers Latest Updated 2024 (Already Graded!!)
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $17.49
- + learn more
FDNY COF P-98 Exam With 100% Correct Answers Latest Updated 2024 (Already Graded!!) Where generally *Fuel-oil is used in buildings?* What purposes?* - Correct AnswerIs used in *Stationary Equipments*, 
Two purposes: 
a) *Fuel Emergency Generators* 
b) *Fuel Equipment used to heat the building* 
2.- What *COF is required* to supervise the *Fuel-oil transfer in the building from one 
floor to another?* - Correct Answer-*P-98 and maintain all qualifications and comply w/ 
requirements applicable to...
-
Gas and Electric Heat Unit 32 Oil Heat exam 2024 with 100% correct answers
- Exam (elaborations) • 21 pages • 2024
- Available in package deal
-
- $16.99
- + learn more
heat-producing system, heat-distributing system correct answersIntroduction to Oil-Fired Forced-Warm-Air Furnaces 
 
Oil-fired forced-warm-air furnaces have two main systems: 
 
A ________________________, consisting of the oil burner, fuel supply components, combustion chamber, and heat exchangers 
A ______________________, consisting of the blower, and other related components 
 
powered, starts correct answersIntroduction to Oil-Fired Forced-Warm-Air Furnaces 
 
When thermostat calls for heat...
-
P98 Exam Questions With 100% Correct Answers, Latest Updated 2024/2025 (GRADED A+)
- Exam (elaborations) • 24 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
P98 Exam Questions With 100% Correct Answers, Latest Updated 2024/2025 (GRADED A+) Fuel-oil is generally used in buildings in stationary equipment for two purposes - Correct 
Answer-fuel emergency generators or to fuel equipment used to heat the building. 
the person supervising the Fuel-Oil Transfer in the Building from one floor to another 
must hold - Correct Answer-P-98 Certificate of Fitness. Certificate of Fitness holders 
must maintain all qualifications and comply with all requirements a...
-
P98 Exam Questions With 100% Correct Answers, Latest Updated 2024/2025 (GRADED)
- Exam (elaborations) • 24 pages • 2024
- Available in package deal
-
- $16.49
- + learn more
P98 Exam Questions With 100% Correct Answers, Latest Updated 2024/2025 (GRADED) Fuel-oil is generally used in buildings in stationary equipment for two purposes - Correct 
Answer-fuel emergency generators or to fuel equipment used to heat the building. 
the person supervising the Fuel-Oil Transfer in the Building from one floor to another 
must hold - Correct Answer-P-98 Certificate of Fitness. Certificate of Fitness holders 
must maintain all qualifications and comply with all requirements appl...
Too much month left at the end of the money?
-
FDNY COF P-98 Exam With 100% Correct Answers 2024 Latest Updated Solved Graded A+
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
FDNY COF P-98 Exam With 100% Correct Answers 2024 Latest Updated Solved Graded A+. What *COF is required* to supervise the *Fuel-oil transfer in the building from one 
floor to another?* - Correct Answer-*P-98 and maintain all qualifications and comply w/ 
requirements applicable to such certificate holder* 
*The P-98 COF is premise-related* 
3.- The use of the word *should* refers to: - Correct Answer-*Polices, procedures and / 
or best practices recommended by the FDNY* 
4.- The use of the wor...
-
FDNY COF P-98 Exam Questions With 100% Correct Answers 2024 Latest Updated Already Graded!!
- Exam (elaborations) • 22 pages • 2024
-
- $17.99
- + learn more
FDNY COF P-98 Exam Questions With 100% Correct Answers 2024 Latest Updated Already Graded!! Where generally *Fuel-oil is used in buildings?* What purposes?* - Correct AnswerIs used in *Stationary Equipments*, 
Two purposes: 
a) *Fuel Emergency Generators* 
b) *Fuel Equipment used to heat the building* 
2.- What *COF is required* to supervise the *Fuel-oil transfer in the building from one 
floor to another?* - Correct Answer-*P-98 and maintain all qualifications and comply w/ 
requirements appli...
-
Oil Tech 134 Questions with Complete Solutions 100% Verified
- Exam (elaborations) • 12 pages • 2024
-
- $10.49
- + learn more
Oil Tech 134 Questions with Complete Solutions 100% Verified 
Which of these are chemical elements found in petroleum products - Correct Answer Hydrogen, Carbon, Sulfur 
 
Minimum flash point of #2 Fuel is - Correct Answer 100 degrees F 
 
What's the ignition point of #2 fuel - Correct Answer 500 degrees F 
 
why is bio-heat fuel important to our future - Correct Answer -customers want to help the environment 
-the public will use it 
-when added to low sulfur it burns cleaner than gas 
 
wha...
-
unit 32.1 Oil Heat exam 22024 with complete solutions
- Exam (elaborations) • 17 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
The oil-fired, forced-warm-air furnace has two main systems which are those? correct answers1. producing system 
2. heat distribution system 
 
What is a heat producing system on oil heat? correct answersconsist in the oil burner, fuel supply components, combustion chamber, and heat exchanger. 
 
What is heat distribution system compose oil heat? correct answersis compose of the blower, which moves the air through the ductwork and relates components 
 
on oil heat the thermostat will cause the ...
-
4A Unit 12 Questions and Answers Graded A+
- Exam (elaborations) • 42 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
4A Unit 12 Questions and Answers 
 
Graded A+ 
 
(4-063-1.14) The operator, while blowing off a boiler, should have an assistant to: 
Select one: 
a. Open the blow-off tank drain 
b. Watch the gauge glass level 
c. Close the quick opening valve in a hurry 
d. Open the slow opening valve b. Watch the gauge glass level 
 
(4-091-3.3) In a mechanical atomizing burner with three fixed capacity burners, the Intermediate 
and high fire burner nozzles may have higher capacities than the primary burner ...