Aci grade 1 field Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Aci grade 1 field? On this page you'll find 535 study documents about Aci grade 1 field.

Page 3 out of 535 results

Sort by

ACI Grade 1 Field Testing Certification Practice  Test – Irving Correctly Answered Questions|  UpToDate | Already Graded A+
  • ACI Grade 1 Field Testing Certification Practice Test – Irving Correctly Answered Questions| UpToDate | Already Graded A+

  • Exam (elaborations) • 17 pages • 2024
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) ☑: False (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) ☑: The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) ☑: 30 to 120...
    (0)
  • $12.49
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test Questions & Answers!!   For
  • ACI Grade 1 Field Testing Certification Practice Test Questions & Answers!! For

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (True or False) - ANSWER False The temperature measuring device must be accurate to within 0.1 degrees. (True or False) - ANSWER False The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of ______ to ______ Fahrenheit ( - ANSWER A composite sa...
    (0)
  • $9.99
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test – Irving 100% Verified.
  • ACI Grade 1 Field Testing Certification Practice Test – Irving 100% Verified.

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - ANSWER False (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) - ANSWER The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) - ANSWER 3...
    (0)
  • $14.99
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test - Irving Questions and Answers 100% Solved correctly
  • ACI Grade 1 Field Testing Certification Practice Test - Irving Questions and Answers 100% Solved correctly

  • Exam (elaborations) • 10 pages • 2024
  • Available in package deal
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) - Answer-False (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) - AnswerThe temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to ______ degree C) - Answer-30 to...
    (0)
  • $7.99
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test  Questions & Answers Solved 100% Correct!!
  • ACI Grade 1 Field Testing Certification Practice Test Questions & Answers Solved 100% Correct!!

  • Exam (elaborations) • 9 pages • 2024
  • Available in package deal
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (True or False) - AnswerFalse The temperature measuring device must be accurate to within 0.1 degrees. (True or False) - AnswerFalse The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of ______ to ______ Fahrenheit ( - AnswerA composite sample is n...
    (0)
  • $7.99
  • + learn more
ACI Concrete Field Testing Technician - Grade 1 (18) 100% Accurate
  • ACI Concrete Field Testing Technician - Grade 1 (18) 100% Accurate

  • Exam (elaborations) • 21 pages • 2024
  • Available in package deal
  • ACI Concrete Field Testing Technician - Grade 1 (18) 100% Accurate ACI Concrete Field Testing Technician - Grade 1 (18) 100% Accurate ACI Concrete Field Testing Technician - Grade 1 (18) 100% Accurate ACI Concrete Field Testing Technician - Grade 1 (18) 100% Accurate ACI Concrete Field Testing Technician - Grade 1 (18) 100% Accurate ASTM C1064 - ANSWER Standard Test Method For Temperature of Freshly Mixed Hydraulic-Cement Concrete The end of the temperature sensing portion of the temperatur...
    (0)
  • $12.99
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test - 2024
  • ACI Grade 1 Field Testing Certification Practice Test - 2024

  • Exam (elaborations) • 10 pages • 2024
  • Available in package deal
  • ACI Grade 1 Field Testing Certification Practice Test - 2024 For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (T or F) -Answer-False (2-5 minutes) The temperature measuring device must be accurate to within 0.1 degree. (T or F) - Answer- The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of _...
    (0)
  • $12.49
  • + learn more
ACI- Concrete Field-Testing Technician - Grade 1 Questions with complete solutions
  • ACI- Concrete Field-Testing Technician - Grade 1 Questions with complete solutions

  • Exam (elaborations) • 58 pages • 2024
  • ACI- Concrete Field-Testing Technician - Grade 1 Questions with complete solutions
    (0)
  • $15.99
  • + learn more
ACI Grade 1 Field Testing Certification Practice Test Questions & Answers 100% Correct.
  • ACI Grade 1 Field Testing Certification Practice Test Questions & Answers 100% Correct.

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • For concrete with aggregates less than 3 inches, the thermometer must remain in the fresh concrete sample a minimum of 5 minutes or until the temperature reading stabilizes. (True or False) - ANSWER False The temperature measuring device must be accurate to within 0.1 degrees. (True or False) - ANSWER False The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete throughout a range of ______ to ______ Fahrenheit ( - ANSWER A composite sa...
    (0)
  • $13.49
  • + learn more
ACI Concrete Field-Testing Technician - Grade 1 Exam Review | 100% Correct Answers | Verified | Latest 2024 Version
  • ACI Concrete Field-Testing Technician - Grade 1 Exam Review | 100% Correct Answers | Verified | Latest 2024 Version

  • Exam (elaborations) • 43 pages • 2024
  • Available in package deal
  • ACI Concrete Field-Testing Technician - Grade 1 Exam Review | 100% Correct Answers | Verified | Latest 2024 Version
    (0)
  • $14.49
  • + learn more