C clotting in dialyzer - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about C clotting in dialyzer? On this page you'll find 176 study documents about C clotting in dialyzer.

Page 3 out of 176 results

Sort by

Fresenius Exam- Dialysis
  • Fresenius Exam- Dialysis

  • Other • 10 pages • 2023
  • Available in package deal
  • Dialysate is kept in the temperature range of... - Answer- 34.5-36.5°C Too warm dialysate can... - Answer- Cause the patient's RBC's to burst (hemolysis), as well as, cause hyperthermia. Too cold dialysate can.. - Answer- Cause the patient's to feel cold and less diffusion of dialysate will occur. However, slightly cool dialysate can help prevent deadly hypotension and organ stunning due to the constriction of blood vessels. Conductivity definition - Answer- How well fluid conducts ...
    (0)
  • $12.49
  • + learn more
CCHT practice exam 238 Questions with Verified Answers,100% CORRECT
  • CCHT practice exam 238 Questions with Verified Answers,100% CORRECT

  • Exam (elaborations) • 21 pages • 2023
  • Available in package deal
  • CCHT practice exam 238 Questions with Verified Answers Annually - CORRECT ANSWER AAMI Chemical Analysis of water used for Hemodialysis is tested Clean the machine surface immediately - CORRECT ANSWER A dialysis technician observes a drop of blood on the surface of a patient's hemodialysis machine. Which of these actions should the dialysis technician take? About one ounce (30 ml) fluid is on the floor - CORRECT ANSWER A dialysis technician observes all of the below on the treatment flo...
    (0)
  • $11.99
  • + learn more
BONENT Review Quiz Questions with 100% Correct Answers
  • BONENT Review Quiz Questions with 100% Correct Answers

  • Exam (elaborations) • 22 pages • 2023
  • Available in package deal
  • management of pericarditis might include all of the following EXCEPT: a. controlled hepranization during dialysis b. aggressive BP control c. increased frequency of dialysis d. use of anti-inflammatory drugs - b. aggressive BP control A patient telephones the dialysis unit to complain of shortness of breath. The technician is concerned because she realizes that this symptom in indicative of: a. cardiac problems b. disequilibrium syndrome c. fluid overload d. high serum potssiu...
    (0)
  • $11.49
  • + learn more
Bonent CDC Questions and Answers 100% Pass
  • Bonent CDC Questions and Answers 100% Pass

  • Exam (elaborations) • 15 pages • 2023
  • Available in package deal
  • Bonent CDC Questions and Answers 100% Pass How to manage Pericarditis: controlled heparinization, increased frequency of dialysis, use of anti-inflammatory drugs A pt telephones the clinic to c/o s.o.b. this symptom is indicative of what? fluid overload Which organization is primarily concerned with providing the unit staff with educational oppotunities? Council of Nephrology Nurses and Technicians of the National Kidney Foundation All of these are essential to the successful completion of a ...
    (0)
  • $9.99
  • + learn more
CCHT PRACTICE EXAM 96 Questions with Verified Answers,100% CORRECT
  • CCHT PRACTICE EXAM 96 Questions with Verified Answers,100% CORRECT

  • Exam (elaborations) • 17 pages • 2023
  • CCHT PRACTICE EXAM 96 Questions with Verified Answers True or False: Peritoneal dialysis (PD) differs from hemodialysis in that PD access is by an intra-abdominal catheter - CORRECT ANSWER TRUE The term :sieving coefficient of a membrane" refers to the: a. fraction of solute that passes through the membrane by convection b. amount of water required for solute drag through the membrane c. concentration of pores in the membrane d. seize of the pores in the membrane - CORRECT ANSWER a...
    (0)
  • $11.99
  • + learn more
   CCHT exam Q's 148 Questions with Verified Answers,100%  CORRECT
  • CCHT exam Q's 148 Questions with Verified Answers,100% CORRECT

  • Exam (elaborations) • 34 pages • 2023
  • CCHT exam Q's 148 Questions with Verified Answers AAMI Chemical Analysis of water used for hemodialysis is tested: annually monthly semi-annually quarterly - CORRECT ANSWER annually A 58-year old patient who is blind comes to treatment accompanied by his wife. Which of these approaches should the dialysis technician use when interacting with the patient? Avoid using phrases that refer to sight, such as "It looks like..." Describe the activities in the immediate envir...
    (0)
  • $12.99
  • + learn more
DIALYSIS - FRESENIUS EXAM|UPDATED&VERIFIED|100% SOLVED|GUARANTEED SUCCESS
  • DIALYSIS - FRESENIUS EXAM|UPDATED&VERIFIED|100% SOLVED|GUARANTEED SUCCESS

  • Exam (elaborations) • 16 pages • 2023
  • Available in package deal
  • Dialysate is kept in the temperature range of... 34.5-36.5°C Too warm dialysate can... Cause the patient's RBC's to burst (hemolysis), as well as, cause hyperthermia. Must See! Eyewitness Captures the Moment a Pair of Male Sea Lions Attack Beach-Goers Too cold dialysate can.. Cause the patient's to feel cold and less diffusion of dialysate will occur. However, slightly cool dialysate can help prevent deadly hypotension and organ stunning due to the constriction of bloo...
    (0)
  • $13.99
  • + learn more
Fresenius PCT Practice Test Questions and Answers
  • Fresenius PCT Practice Test Questions and Answers

  • Exam (elaborations) • 6 pages • 2023
  • Available in package deal
  • Fresenius PCT Practice Test Questions and Answers Which of the following would keep KECN values stable during treatment: a. missed heparin dose b. BFR set as prescribed c. clotting in dialyzer d. poor arterial flow from the access
    (0)
  • $5.49
  • + learn more
Clinical Annual Competency Exam – Fresenius correct answers 100%
  • Clinical Annual Competency Exam – Fresenius correct answers 100%

  • Exam (elaborations) • 5 pages • 2024
  • Clinical Annual Competency Exam – Fresenius correct answers 100% Inadequate Heparinization - correct answer The adequacy of a dialysis treatment may be compromised by Post reinfusion and prior to disconnection - correct answer Routine post dialysis treatment documentation on the patients dialysis treatment record should include patients blood pressure and temperature both Chemical content - correct answer Individual acid containers should be labeled with Notify the RN - correct ans...
    (0)
  • $9.49
  • + learn more
Bonent review exam 2023 questions with correct answers
  • Bonent review exam 2023 questions with correct answers

  • Exam (elaborations) • 17 pages • 2023
  • When the hemodialysis machine detects a blood leak, there will be an audio and visual alarm and the A. blood pump will stop. B. air detector will alarm C. machine will go into bipass D. conductivity alarm will occur - Answer- A Management of pericarditis might include all of the following EXPECT? A. Controlled heparinization during dialysis. B. Agressive blood pressure control. C. Increased frequency of dialysis. D. Use of anti-inflammatory drugs. - Answer- B A patient tele...
    (0)
  • $12.49
  • + learn more