Residential Electrician Exam #1 || Questions and Answers 100% Correct
- Exam (elaborations) • 11 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
Residential Electrician Exam #1 || Questions and Answers 100% Correct 
Residential Electrician Exam #1 || Questions and Answers 100% Correct 
 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only - ANSWER-A: electrically continuous 
Ref: 250.64(E) 
 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. 
a) swi...
-
Journeyman Open Book Practice Exam | Questions with 100% Correct Answers | Latest Update 2024 | Verified
- Exam (elaborations) • 9 pages • 2024
-
- $9.99
- + learn more
Journeyman Open Book Practice Exam | Questions with 100% Correct Answers | Latest Update 2024 | Verified 
where extensive metal in or on buildings or structures may become energized and is subject to 
personal contact _______ will provide additional safety. 
a) adequate bonding and grounding 
b) bonding 
c) suitable ground detectors 
d) none of these - a) adequate bonding and grounding 
single conductor cables shall be ______ or larger and shall be of a type listed for use in cable 
trays. 
(a) ...
-
Residential Electrician Exam #1 questions and answers all are correct graded A+
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only - Answer-A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control 
_____. 
a) switched receptacles for cord-connected incandescent luminaires 
b) permanently installed incandescent luminaires 
c) ceiling fans with luminaires 
...
-
Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Graded A+
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $9.59
- + learn more
Residential Electrician Exam #1Complete Questions With 100% Correct Answers. 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only 
A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. 
a) switched receptacles for cord-connected incandescent luminaires 
b) permanently...
-
Journeyman Electrician Practice Exam #7 Questions And Answers
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Electrician Practice Exam #7 
Questions And Answers 
Where the outer sheath of Type MI cable is made of steel _____________. 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
B. a separate equipment grounding conductor shall be provided 
C. the grounding and grounded conductors shall be connected together 
D. it shall not be longer than 6 feet - answerB. a separate equipment grounding conductor 
shall be provided 
The interior of enclosures or raceway...
Make study stress less painful
-
Journeyman Final Exam Questions And Answers 100% Verified
- Exam (elaborations) • 11 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Final Exam Questions And 
Answers 100% Verified 
Which of the following conductor insulation types, if any, is/are acceptable for wiring in a 
fluorescent luminaire when the branch-circuit conductor passes within three (3) inches of the 
ballast? 
I. THW 
II. THWN 
1.) neither I nor II 
2.) both I and II 
3.) I only 
4.) II only - answerAnswer: both I and II 
Table 310.4(A) on page 70-153 of the NEC® 2020 
Fire pump supply conductors on the load side of the final disconnecting means ...
-
Gas Tech II Exam Questions and Answers 100% Pass
- Exam (elaborations) • 33 pages • 2024
- Available in package deal
-
- $10.99
- + learn more
Gas Tech II Exam Questions and Answers 100% Pass 
1) What is the minimum diameter of a pressure gauge needed to perform leak test on gas piping? 3" 
2) Amp meter can read what? Conductor magnetic field. 
3) What would be the primary voltage of a furnace? 120/1/60. 
4) What is the function of an intermittent pilot? Stay on during the main burner operation. 
5) What is the millivolts power output on a thermocouple closed circuit test? 10 to 15 millivolts. 
6) A pilot with a lazy yellow flame woul...
-
Journeyman Electrician Practice Exam #7 Questions And Answers
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Journeyman Electrician Practice Exam #7 
Questions And Answers 
Where the outer sheath of Type MI cable is made of steel _____________. 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
B. a separate equipment grounding conductor shall be provided 
C. the grounding and grounded conductors shall be connected together 
D. it shall not be longer than 6 feet - answerB. a separate equipment grounding conductor 
shall be provided 
The interior of enclosures or raceway...
-
Fire Investigator - Master for TCFP (Test Bank) Questions With Answers Latest Updated 2024/2025 Graded A+ | 100% Verified.
- Exam (elaborations) • 93 pages • 2024
- Available in package deal
-
- $17.99
- + learn more
Fire Investigator - Master for TCFP (Test Bank) Questions AND Answers Latest Updated 2024/2025 Graded A+ | 100% Verified. Is NFPA 921 a guide or a standard? - It is the Guide for Fire and Explosion 
Investigations 
What are the six steps of the scientific method? - Recognize the need 
Define the problem 
Collect the data 
Analyze the data 
Develop a hypothesis 
Test the hypothesis 
What step of the scientific method is inductive reasoning? - Analyze the data 
What step of the scientific method i...
-
Residential Electrician Exam #1 questions with correct answers
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only CORRECT ANSWER A: electrically continuous 
Ref: 250.64(E) 
 