Journeyman Electrician #5 | Questions and Correct Answers | Latest Update 2024/2025 | Graded A+
- Exam (elaborations) • 13 pages • 2024
- Available in package deal
-
- $10.99
- + learn more
Journeyman Electrician #5 | 
Questions and Correct Answers | 
Latest Update 2024/2025 | 
Graded A+ 
Unless listed and identified otherwise, terminations and conductors of 
sizes 14 AWG through 1 AWG shall be rated at _____. 
a) 75°C 
b) 75°F 
c) 90°C 
d) 60°C - Answer -D: 60°C 
Ref: 110.14(C)(1)(a)(1) 
The MINIMUM size copper equipment bonding jumper on the supply 
side of a service consisting of parallel copper phase conductors with a 
total circular mil area of 2000 kcmil shall be ____.a)...
-
Journeyman Electrician CH #4 Assessment Test Questions and Answers
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Journeyman Electrician CH #4 Assessment Test Questions and Answers 
 
 
Class 3 single-conductors shall NOT be smaller than _____. 
 
a) 18 AWG 
b) 16 AWG 
c) 14 AWG 
d) 20 AWG - Answer-A: 18 AWG 
Ref: 725.179(H) 
 
Given: an office building has a 208Y/120 volt, three-phase service with a balanced net computed load of 90 kVA. What is the current each ungrounded conductor carries at full load? 
 
a) 188 amperes 
b) 250 amperes 
c) 433 amperes 
d) 750 amperes - Answer-B: 250 amperes 
Ref: Trade an...
-
Journeyman Electrician Questions and Answers with Verified Solutions
- Exam (elaborations) • 19 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
Journeyman Electrician Questions and Answers with Verified Solutions 
For other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of the electrical service equipment? 50 feet 
The ampacity of a conductor is defined by the NEC to be the maximum current, in amperes, a conductor can carry continuously under the conditions of use without exceeding ______? ...
-
Journeyman Electrician Test With Solutions 100% Solved
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $16.99
- + learn more
Journeyman Electrician Test With Solutions 
100% Solved 
Where a one-family dwelling has a 200 amp, 120/240 volt, single phase main service panel and 
is supplied with size 2/0 gauge THW copper ungrounded line service entrance conductors in 
rigid metal conduit, the minimum required size of the bonding jumper for this service entrance 
conduit is _____ copper. 4 AWG 
A disconnect switch enclosure installed in a Class 2, division 2, hazardous location in an 
industrial establishment shall be...
-
Journeyman Electrician | Questions and Correct Answers | Latest Update 2024/2025
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $11.99
- + learn more
Journeyman Electrician | 
Questions and Correct Answers | 
Latest Update 2024/2025 
For other than one-and two-family dwellings, when building a new 
electrical service, at least one (1) 125-volt, single-phase, 15- or 20- 
ampere-rated receptacle outlet shall be located within at LEAST _____ 
of the electrical service equipment? - Answer -50 feet 
The ampacity of a conductor is defined by the NEC to be the maximum 
current, in amperes, a conductor can carry continuously under the 
conditions of ...
Get paid weekly? You can!
-
Journeyman Electrician #4 Exam Questions and Answers
- Exam (elaborations) • 11 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Electrician #4 Exam 
Questions and Answers 
Where conduits enter a floor-standing switchboard or panelboard at the bottom, the 
conduits including their end fittings, shall not rise more than _____ above the bottom of 
the enclosure. 
a) 6 inches 
b) 4 inches 
c) 2 inches 
d) 3 inches -Answer-D: 3 inches 
Ref: 408.5 
When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be 
connected _____. 
a)on the line side of the service disconnect overcurrent device ...
-
Journeyman Electrician Exam 1 - Q & A
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
Journeyman Electrician Exam 1 - Q & A When a pull box contains conductors of size 4 AWG and larger and a straight pull of the conductors is to be made, the length of the box shall NOT be less than _____ times the trade diameter of the largest conduit entering the box. a) six b) four c) eight d) twelve Ref: 314.28(A)(1) In general, all of the following wiring methods listed are permitted to be used as a feeder for temporary wiring on a construction site EXCEPT _____. a) NM cable b) NMC cable c)...
-
Journeyman electrician exam prep 2024
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman electrician exam prep 2024 
What table sizes bonding jumpers for for AC systems? -Answer-250.102(C)(1) 
The NEC defines continuous load to be a load where max current on the circuit 
continues for at least how many hours? -Answer-Three 
To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how 
many current carrying conductors in a raceway? -Answer-Greater than three 
Where in the NEC codebook would you find EMT sizes for a given size and number of 
conduc...
-
Journeyman Electrician Practice Test | Questions and Correct Answers | Latest Update 2024/2025
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $11.99
- + learn more
Journeyman Electrician Practice 
Test | Questions and Correct 
Answers | Latest Update 
2024/2025 
Conductors with _____ marked on the insulation are NOT approved for 
use in a wet location. - Answer -THHN 
conductors with THHN insulation are approved for use in dry and damp 
locations only and conductors with THWN, THHW, and THW insulation 
are recognized for use in dry and wet locations. 
Given: A one-family dwelling unit with a demand load of 200 amperes is 
supplied with a 120/240 volt, sing...
-
Journeyman Electrician Exam Prep
- Exam (elaborations) • 13 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
Journeyman Electrician Exam Prep 
 
What table sizes bonding jumpers for for AC systems? - 250.102(C)(1) 
 
The NEC defines continuous load to be a load where max current on the circuit continues for at 
least how many hours? - Three 
 
To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many 
current carrying conductors in a raceway? - Greater than three 
 
Where in the NEC codebook would you find EMT sizes for a given size and number of 
conductors? - Annex C...