Driver/Pumper OperatorCoefficient for 1 3/4" with 1 1/2" couplings - correct answer 15.5 
 
Coefficient for 2" - correct answer 8 
 
Coefficient for 2 1/2" - correct answer 2 
 
Coefficient for 3" with 2 1/2" couplings - correct answer .8 
 
Coefficient for 3" with 3" couplings - correct answer .677 
 
Coefficient for 4" - correct answer .2 
 
Coefficient for 5" - correct answer .08 
 
FL - correct answer Friction Loss in PSI 
 
C - correct answer Friction Loss coefficient 
 
Q - corre...
-
Driver Pumper Operator Questions And Answers 2024.
- Exam (elaborations) • 27 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Driver Pumper Operator Questions And Answers 2024. 
Coefficient for 1 3/4" with 1 1/2" couplings - correct answer 15.5 
 
Coefficient for 2" - correct answer 8 
 
Coefficient for 2 1/2" - correct answer 2 
 
Coefficient for 3" with 2 1/2" couplings - correct answer .8 
 
Coefficient for 3" with 3" couplings - correct answer .677 
 
Coefficient for 4" - correct answer .2 
 
Coefficient for 5" - correct answer .08 
 
FL - correct answer Friction Loss in PSI 
 
C - correct answer Friction...
-
Fire Inspector 2 Study Guide (State of Florida) Questions with 100% Correct Answers | Verified | Latest Update 2024
- Exam (elaborations) • 20 pages • 2024
-
- $13.49
- + learn more
1.	Fire protection engineers have established PSI as a minimum re- quired residual pressure when computing the available water for flow test results. 
ANS 20psi 
2.	The most common gallonage rating for horizontal shaft pumps in use today are	-	GPM. 
ANS 500 - 1500 gpm 
3.	A fire pump serving a standpipe system should be tested	 
ANS weekly 
4.	A fire department pumper can effectively supply around	feet in a high rise building depending on hydrant pressure and other factors. 
ANS 450 feet 
5.	Cla...
-
Driver/Pumper Operator question and answers graded A+ 2023/2024
- Exam (elaborations) • 27 pages • 2024
- Available in package deal
-
- $19.99
- + learn more
Driver/Pumper Operator 
Coefficient for 1 3/4" with 1 1/2" couplings - correct answer 15.5 
 
Coefficient for 2" - correct answer 8 
 
Coefficient for 2 1/2" - correct answer 2 
 
Coefficient for 3" with 2 1/2" couplings - correct answer .8 
 
Coefficient for 3" with 3" couplings - correct answer .677 
 
Coefficient for 4" - correct answer .2 
 
Coefficient for 5" - correct answer .08 
 
FL - correct answer Friction Loss in PSI 
 
C - correct answer Friction Loss coefficient 
 
Q - cor...
-
Texas Commission on Fire Protection (TCFP) Driver/ Operator Test Questions and Answers 2024/2025 (GRADED)
- Exam (elaborations) • 35 pages • 2024
-
- $13.99
- + learn more
In 1720 what was the piece of equipment to replace the bucket brigade? 
Hand Pump 
Which NFPA standard required new fire apparatus to be designed so that all members riding on the fire 
apparatus would be provided a seated area inside an enclosed cab? 
NFPA 1500 
What was the first gasoline powered fire apparatus to discharge water by using a large soda acid 
extinguisher? 
Chemical Wagon 
The real breakthrough for today's modern fire apparatus came with the introduction of the 
_______________...
Fear of missing out? Then don’t!
-
PUMPER EOC QUESTIONS AND ANSWERS 100% SOLVED
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
PUMPER EOC QUESTIONS AND 
ANSWERS 100% SOLVED 
The benefit of an apparatus-mounted generator on a fire apparatus is that it can provide 50 
kilowatts, whereas a portable generator can only produce: ️️5 kilowatts 
All of the following are rescue tools EXCEPT ️️drills 
Identify TWO items that should be included on daily fire apparatus ️️-Tire Condition 
-Coolant levels 
On the vacuum services test, the system vacuum and pump priming device should achieve a 
column of mercury of at ...
-
Pumper CDC Questions and Answers Fully Solved
- Exam (elaborations) • 9 pages • 2024
- Available in package deal
-
- $18.99
- + learn more
Pumper CDC Questions and Answers Fully Solved 
A fire apparatus should be started with all electrical switches in the OFF position in order to: 
Start the engine without a load. 
 
 
 
During an inspection of your fire apparatus, you should ensure that the foam level is: 
Full 
 
 
 
Match the location of each fire apparatus inspection item to the name that applies 
saddle tanks - 6 
winch - 7 
main hose bed - 2 
automatic snow chains - 4 
intake strainers - 5 
ladders - 3 
compartments - 1 
 
 ...
-
Driver Operator Pumper Questions with solutions
- Exam (elaborations) • 16 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
Driver Operator Pumper Questions with solutions 
NFPA 1901 
Standard for Automotive Fire Apparatus 
 
 
 
300 gallons 
NFPA 1901 states that pumpers must have a water capacity of at least 
 
 
 
 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
Unmute 
0:01 
/ 
0:15 
Full screen 
Brainpower 
Read More 
Rescue pumper 
Specially designed apparatus that combines the functions of both a rescue vehicle and a fire department pumper 
 
 
 
CAFS 
High-energy foam generation system cons...
-
DOP IFSTA Written Test Questions that were missed with Correct Solutions
- Exam (elaborations) • 82 pages • 2023
- Available in package deal
-
- $13.99
- + learn more
Which of the following is NOT a responsibility of the fire apparatus driver/operator? (7) 
 
A. Detailed maintenance procedures 
B. Operating the apparatus properly, swiftly, and safely 
C. Ensuring that the apparatus and the equipment it carries are ready at all times 
D. Safely transporting firefighters, apparatus, and equipment to and from the scene of an emergency or other call for service - A. Detailed maintenance procedures 
 
Which of the following is NOT a basis for promotion to drive...
-
Driver/Pumper Operator question n answers graded A+ 2023/2024
- Exam (elaborations) • 27 pages • 2023
- Available in package deal
-
- $19.99
- + learn more
Driver/Pumper OperatorCoefficient for 1 3/4" with 1 1/2" couplings - correct answer 15.5 
 
Coefficient for 2" - correct answer 8 
 
Coefficient for 2 1/2" - correct answer 2 
 
Coefficient for 3" with 2 1/2" couplings - correct answer .8 
 
Coefficient for 3" with 3" couplings - correct answer .677 
 
Coefficient for 4" - correct answer .2 
 
Coefficient for 5" - correct answer .08 
 
FL - correct answer Friction Loss in PSI 
 
C - correct answer Friction Loss coefficient 
 
Q - corre...
Do you wonder why so many students wear nice clothes, have money to spare and enjoy tons of free time? Well, they sell on Stuvia! Imagine your study notes being downloaded a dozen times for $15 each. Every. Single. Day. Discover all about earning on Stuvia