Phase transformer - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Phase transformer? On this page you'll find 974 study documents about Phase transformer.

Page 4 out of 974 results

Sort by

Master Electrician (First Set 1-85) with Complete Solutions
  • Master Electrician (First Set 1-85) with Complete Solutions

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • Master Electrician (First Set 1-85) with Complete SolutionsMaster Electrician (First Set 1-85) with Complete SolutionsMaster Electrician (First Set 1-85) with Complete SolutionsMaster Electrician (First Set 1-85) with Complete Solutions A 150 kVA service transformer has a 480Y/277 volt 3-phase primary and a 208Y/120 volt, 3-phase secondary. What is the approximate full-load ampere rating of the primary of the transformer? - ANSWER-180 amperes Where a conductor is marked RHW-2 on the insulati...
    (1)
  • $10.99
  • + learn more
Practice Test NERC Questions with Complete Solutions Rated A+
  • Practice Test NERC Questions with Complete Solutions Rated A+

  • Exam (elaborations) • 26 pages • 2023
  • Available in package deal
  • A transmission line is operating with a voltage phase angle different of 30 degrees between the sending Vs and the receiving bus Vr. If the receiving end load is suddenly increased, the voltage phase angle difference will be? -Answer The phase angle will increase. When load is increased phase angle will increase. A load has a power factor of 0.9 lagging. If the load draws 100 MVA, what is the MW draw? - Answer 90 pf= mw/mva The high side of a delta-wye connection transformer is connected t...
    (0)
  • $13.49
  • + learn more
Enphase Storage Design Certification Training Questions and Answers Already  Passed
  • Enphase Storage Design Certification Training Questions and Answers Already Passed

  • Exam (elaborations) • 19 pages • 2024
  • Enphase Storage Design Certification Training Questions and Answers Already Passed Which component of the Ensemble system detects a grid failure? A. Envoy B. Enpower C. Encharge B. Enpower True or false: PV systems with Energy storage but without backup power do not require Enpower. True Where do the hot conductors between Encharge and Enpower terminate? A. In the IQ Combiner box B. At the DER (distributed energy resource) input terminals C. On the Encharge circui...
    (0)
  • $9.99
  • + learn more
Progression: Maintenance Tech I - II Conventional: Exam Review Answered.
  • Progression: Maintenance Tech I - II Conventional: Exam Review Answered.

  • Other • 12 pages • 2023
  • Progression: Maintenance Tech I - II Conventional: Exam In the tree-and-branch architecture, how is the downstream signal from the trunk fed to the distribution branches? What is a common solution when congestion from modem activity and traffic becomes unacceptable in a hybrid fiber/coax (HFC) network? What technologies are defined in DOCSIS 4.0 to help sustain the hybrid fiber/coax (HFC) network infrastructure for several more years? How can a less-experienced technician identi...
    (1)
  • $10.39
  • 2x sold
  • + learn more
Practice Test NERC Questions with correct answers
  • Practice Test NERC Questions with correct answers

  • Exam (elaborations) • 32 pages • 2023
  • Available in package deal
  • A transmission line is operating with a voltage phase angle different of 30 degrees between the sending Vs and the receiving bus Vr. If the receiving end load is suddenly increased, the voltage phase angle difference will be? CORRECT ANSWER The phase angle will increase. When load is increased phase angle will increase. A load has a power factor of 0.9 lagging. If the load draws 100 MVA, what is the MW draw? CORRECT ANSWER 90 pf= mw/mva The high side of a delta-wye connection transformer i...
    (0)
  • $15.49
  • + learn more
NERC ~ RC (NP3 Transmission) questions with correct answers
  • NERC ~ RC (NP3 Transmission) questions with correct answers

  • Exam (elaborations) • 21 pages • 2023
  • Available in package deal
  • Q32618 When a high voltage transmission line circuit breaker trips open as a result of a fault, a synchronous check relay will monitor certain values on both the line side and the bus side of the open circuit breaker. Before the synchronous check relay re-closes the open circuit breaker, which of the following values has to be within a certain limit before the circuit breaker will close automatically? CORRECT ANSWER •) Frequency •) Voltage Magnitudes •) Phase Angle between the voltages ...
    (0)
  • $14.99
  • + learn more
Electrical Theory Practice Test Questions And 100% Correct Answers.
  • Electrical Theory Practice Test Questions And 100% Correct Answers.

  • Exam (elaborations) • 4 pages • 2024
  • Available in package deal
  • Voltmeter - Answer A high resistance is connected in series with the internal coil of a galvanometer to make? If a transformer ratio is 20/1, what does it mean for the secondary? - Answer The primary voltage is 20 times greater than that of the secondary. If a motor enclosure is designed to contain sparks or flashes that could ignite surrounding vapors or gases, then the enclosure is considered to be which of the following: - Answer Ventilated The output of a 3-phase transforme...
    (0)
  • $9.49
  • + learn more
Master Electrician Questions & Answers 100%Correct!!
  • Master Electrician Questions & Answers 100%Correct!!

  • Exam (elaborations) • 9 pages • 2024
  • A 150 kVA service transformer has a 480Y/277 volt 3-phase primary and a 208Y/120 volt, 3-phase secondary. What is the approximate full-load ampere rating of the primary of the transformer? - ANSWER180 amperes A 50 kVA transformer with a 480-volt, 3-phase, primary and a 208Y/120 volt, 3-phase secondary is to be installed. Overcurrent protection is required on both primary and secondary sides of the transformer. Determine the MAXIMUM standard size overcurrent protection device permitted on the ...
    (0)
  • $13.49
  • + learn more
TRANSFORMERS NIVEL DOS: REVENGE OF THE XFRMR OCPD W/ ASSOC. TAP RULES
  • TRANSFORMERS NIVEL DOS: REVENGE OF THE XFRMR OCPD W/ ASSOC. TAP RULES

  • Exam (elaborations) • 6 pages • 2024
  • In general, transformer secondary conductors are not considered to be protected by the primary overcurrent protective device. TRUE 240.4(F) An installation consists of a 10-kVA, single-phase transformer with a 440-volt primary and a 110-volt, 2-wire secondary using THWN copper conductors. No secondary OCPD is installed. The secondary loads are considered to be noncontinuous loads. Calculate the minimum size secondary conductors required to handle the secondary full-load current for this transf...
    (0)
  • $11.49
  • + learn more
Ri journeyman exam prep with verified solutions
  • Ri journeyman exam prep with verified solutions

  • Exam (elaborations) • 21 pages • 2024
  • Unused openings in equipment shall be closed To afford protection equivalent to the wall of the equipment With flame resistant tape With metallic or non metallic materials .004 inches in thickness With metal 1/8 inch in thickness correct answersTo afford protection equivalent to the wall of the equipment The interior of raceways installed underground shall be considered to be locations Dry Damp Wet Moist correct answersWet Parallel conductors comprising each phase, polari...
    (0)
  • $17.99
  • + learn more