IDPX EXAM QUESTIONS AND ANSWERS
- Exam (elaborations) • 27 pages • 2023
-
- $12.49
- + learn more
If a project is located in a city that has adopted the IBC, where would the designer look to find requirements on the minimum allowable space between the top of the shelving and the sprinkler heads in the ceiling? 
 
IBC 
International Mechanical Code 
NFPA 13 
IPC - Answer- NFPA 13 
 
Where are flame-spread ratings in a building most restrictive? 
 
in exit enclosures 
on corridor floors 
in access ways to exits 
in enclosed spaces - Answer- in exit enclosures 
 
Exit access corridors in nonspr...
-
NCIDQ - IDFX Practice Exam Questions and Answers 2024
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $12.99
- + learn more
The minimum number of toilet fixtures for an interior design is determined by occupant load and? -Correct Answer Occupancy group 
 
Where are flame spread ratings in a building the MOST restrictive -Correct Answer Exit enclosures 
 
Exit access corridors in non-sprinklered buildings must have a rating of? -Correct Answer 1 hour 
 
When selecting interior partition finishes to meet flame spread standards, the MOST important considerations are? -Correct Answer occupancy group, and the location in ...
-
NCIDQ - IDFX Practice Questions & Answers exam 2024/2025 with 100% correct answers
- Exam (elaborations) • 8 pages • 2024
-
- $14.99
- + learn more
Occupancy group correct answersThe minimum number of toilet fixtures for an interior design is determined by occupant load and? 
 
Exit enclosures correct answersWhere are flame spread ratings in a building the MOST restrictive 
 
1 hour correct answersExit access corridors in non-sprinklered buildings must have a rating of? 
 
occupancy group, and the location in the building where finishes will be used correct answersWhen selecting interior partition finishes to meet flame spread standards, th...
-
NCIDQ IDFX Exam Practice Questions & Answers 2024/2025
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $8.49
- + learn more
NCIDQ IDFX Exam Practice Questions & Answers 2024/2025 
 
 
Occupancy group - ANSWERSThe minimum number of toilet fixtures for an interior design is determined by occupant load and? 
 
Exit enclosures - ANSWERSWhere are flame spread ratings in a building the MOST restrictive 
 
1 hour - ANSWERSExit access corridors in non-sprinklered buildings must have a rating of? 
 
occupancy group, and the location in the building where finishes will be used - ANSWERSWhen selecting interior partition finishe...
-
NYC Master Electrical Exam 2024 Questions and Answers 100% Correct
- Exam (elaborations) • 32 pages • 2024
-
- $11.99
- + learn more
neutral point - ANSWER-The common point on a wye-connection in a polyphase system or midpoint on a single phase, 3-wire system, or midpoint of a single phase portion of a 3-phase delta system, or a midpoint of a 3-wire, direct current system 
 
In the NEC the words ___________indicate a mandatory requirement - ANSWER-Shall or shall not 
 
On a four wire Delta connected system with a midpoint of one phase winding is grounded, only the conductor or bus bar having a higher phase voltage the ground ...
As you read this, a fellow student has made another $4.70
-
NCIDQ - National Council For Interior Design Qualification Certified
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $9.49
- + learn more
NCIDQ - National Council For Interior Design Qualification Certified 
 
Occupancy group - ANS The minimum number of toilet fixtures for an interior design is determined by occupant load and? 
 
Exit enclosures - ANS Where are flame spread ratings in a building the MOST restrictive 
 
1 hour - ANS Exit access corridors in non-sprinklered buildings must have a rating of? 
 
occupancy group, and the location in the building where finishes will be used - ANS When selecting interior parti...
-
NYC Master Electrical Exam PREP TEST QUESTIONS AND ANSWERS 100% | VERIFIED
- Exam (elaborations) • 41 pages • 2024
-
- $14.99
- + learn more
NYC Master Electrical Exam PREP TEST 
QUESTIONS AND ANSWERS 100% | 
VERIFIED 
On a four wire Delta connected system with a midpoint of one phase 
winding is grounded, only the conductor or bus bar having a higher phase 
voltage the ground shall be durably and permanently marked by an outer 
finish that is _______ in color or by other effective means. Such 
Identification shall be placed at each point on the system where connection 
is made if the grounded conductor is also present. - ANSW...
-
NCIDQ-Chap 27-Building Codes Exam Questions 100% Solved.
- Exam (elaborations) • 16 pages • 2024
-
- $12.49
- + learn more
aluation of the safety of a partition system? 
A.) ASTM E84, Standard Test Method for Surface Burning Characteristics of Building Materials 
B.) Steiner tunnel test 
C.) room corner test 
D.) ASTM E119, Standard Test Methods for Fire Tests of Building Construction and Materials - 
answerD is correct. ASTM E119 tests the entire assembly, not just the finish materials like 
©SIRJOEL EXAM SOLUTIONS 
10/11/2024 1:41 PM 
ASTM E84 (also known as the Steiner tunnel test). The ASTM E119 test is best at...
-
Fire Inspector II Test
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
Fire Inspector II Test 
 
Where would you look to determine if the damper requirements have been included and correct 
on a set of drawings? - On the mechanical plan 
 
Which plans sheet gives specific details for exit signs? - Electrical plans 
 
Which plan would you look at to find exit door fire ratings? - Door schedule 
 
All of the following items can be verified on the life safety floor plan Except - The location 
of fire hydrant connections 
 
Which view should inspectors examine to see a...
-
NYC Master Electrical Exam 2024 Questions and Answers 100% Correct!
- Exam (elaborations) • 32 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
neutral point - ANSWER-The common point on a wye-connection in a polyphase system or midpoint on a single phase, 3-wire system, or midpoint of a single phase portion of a 3-phase delta system, or a midpoint of a 3-wire, direct current system 
 
In the NEC the words ___________indicate a mandatory requirement - ANSWER-Shall or shall not 
 
On a four wire Delta connected system with a midpoint of one phase winding is grounded, only the conductor or bus bar having a higher phase voltage the ground ...