EPA Lead Inspector questions and answers latest top score.
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $10.99
- 1x sold
- + learn more
EPA Lead Inspector questions and answers latest top score. 
 
 
 
 
 
 
 
 
 
 
 
 
Lead-based paint (LBP) - correct answers.Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 
 
Dust sample clearance values - correct answers.- Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troug...
-
EPA Lead Inspector Final Exam Questions And Actual Answers 2024.
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
LBP Threshold - Answer 1.0 mg/cm^2 
 
Hazardous waste - Answer >5 ppm via TCLP analysis 
 
Surface dust clearance (Floor) - Answer 10 micrograms/ft^2 
 
Surface dust clearance (Window sills) - Answer 100 micrograms/ft^2 
 
Surface dust clearance (Window wells) - Answer 400 micrograms/ft^2 
 
Drinking water standards (all public water) - Answer 15 ppb for a 750 ml sample 
 
Drinking water standards (Schools and daycare) - Answer 20 ppb for a 250 ml sample 
 
Residential soil stan...
-
EPA LEAD INSPECTOR EXAM QUESTIONS WITH 100% VERIFIED ANSWERS 2024/2025
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $17.99
- + learn more
EPA LEAD INSPECTOR EXAM QUESTIONS WITH 100% VERIFIED ANSWERS 2024/2025. Lead-based paint (LBP) - ANSWER- Any varnish, shallac, or coating that contains 
either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not 
read accurately at 0.7, so the lead standard was updated to 1.0 
Dust sample clearance values - ANSWER- - Floors: 40 μg/ft2 > 10 μg/ft2 (10 
μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window 
wells (troughs): 400 μg/ft2 (100 μg/...
-
Lead Abatement Exam Study Guide Questions and Answers 2024
- Exam (elaborations) • 3 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
Lead based paint - 1.0 mg/cm2 or 0.5% 
 
blood lead level - 10 ug/dl (NH) 5ug/dl (CDC) 
 
Preliminary clearance - After hazards removed 
 
final clearance - Painted, sealed, cleaned, ready for reoccupancy 
 
Hazard - Deteriorated, friction/impact; chewing 
 
Lead inspector job description - Create lead reports 
 
Risk Assessors job description - Identify risk and make recommendations to abatement methods 
 
Abatement - Permanent removal of hazards (20 years) enclosure, encapsulation, removal, re...
-
EPA Lead Inspector Key Compulsory Exam Questions And Correct Answers
- Exam (elaborations) • 7 pages • 2024
-
- $7.99
- + learn more
LBP Threshold 1.0 mg/cm^2 
Hazardous waste >5 ppm via TCLP analysis 
Surface dust clearance (Floor) 10 micrograms/ft^2 
Surface dust clearance (Window sills) 100 micrograms/ft^2 
Surface dust clearance (Window wells) 400 micrograms/ft^2 
Drinking water standards (all public water) 15 ppb for a 750 ml sample 
Drinking water standards (Schools and daycare) 20 ppb for a 250 ml sample 
Residential soil standards (playground) 400 ppm
And that's how you make extra money
-
Lead Abatement Question and answers already passed
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
Lead Abatement Question and answers already passed Lead based paint - correct answer 1.0 mg/cm2 or 0.5% 
 
blood lead level - correct answer 10 ug/dl (NH) 5ug/dl (CDC) 
 
Preliminary clearance - correct answer After hazards removed 
 
final clearance - correct answer Painted, sealed, cleaned, ready for reoccupancy 
 
Hazard - correct answer Deteriorated, friction/impact; chewing 
 
Lead inspector job description - correct answer Create lead reports 
 
Risk Assessors job description -...
-
EPA LEAD INSPECTOR| 111 QUESTIONS AND ANSWERS.
- Exam (elaborations) • 12 pages • 2023
- Available in package deal
-
- $14.99
- + learn more
Lead-based paint (LBP) 
Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 
 
 
 
Dust sample clearance values 
- Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1 sq ft > 2 sq ft (can be reduced to 1 sq ft if withi...
-
Lead Abatement Test Questions with 100% Correct Solutions
- Exam (elaborations) • 3 pages • 2023
- Available in package deal
-
- $9.99
- + learn more
Lead based paint - 1.0 mg/cm2 or 0.5% 
 
blood lead level - 10 ug/dl (NH) 5ug/dl (CDC) 
 
Preliminary clearance - After hazards removed 
 
final clearance - Painted, sealed, cleaned, ready for reoccupancy 
 
Hazard - Deteriorated, friction/impact; chewing 
 
Lead inspector job description - Create lead reports 
 
Risk Assessors job description - Identify risk and make recommendations to abatement methods 
 
Abatement - Permanent removal of hazards (20 years) enclosure, en...
-
EPA Lead Inspector Exam Latest Verified 100% ( Graded A+ ) 2023
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $12.99
- + learn more
EPA Lead Inspector Exam Latest Verified 100% ( Graded A+ ) 2023 
 
Lead-based paint (LBP) - Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 
 
Dust sample clearance values - - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples mu...
-
2024 Updated EPA Lead Inspector exam with answers
- Exam (elaborations) • 9 pages • 2024
-
- $11.99
- + learn more
Lead-based paint (LBP) - ANSWER Any varnish, shallac, or coating that contains 
either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read 
accurately at 0.7, so the lead standard was updated to 1.0 
Dust sample clearance values - ANSWER - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in 
NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 
μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1 sq ft > 2 sq ft (can be reduced to 1 ...