Residential electricians - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Residential electricians? On this page you'll find 166 study documents about Residential electricians.

All 166 results

Sort by

NCCER STUDY GUIDE When is nonmetallic-sheathed cable used - ANSWER-In a residential wiring system Phases of residential electrical wiring include - ANSWER-Rough in, Trim out, Testing and Troubleshooting What two groups are industrial electricians split in
  • NCCER STUDY GUIDE When is nonmetallic-sheathed cable used - ANSWER-In a residential wiring system Phases of residential electrical wiring include - ANSWER-Rough in, Trim out, Testing and Troubleshooting What two groups are industrial electricians split in

  • Exam (elaborations) • 16 pages • 2024
  • NCCER STUDY GUIDE When is nonmetallic-sheathed cable used - ANSWER-In a residential wiring system Phases of residential electrical wiring include - ANSWER-Rough in, Trim out, Testing and Troubleshooting What two groups are industrial electricians split into - ANSWER-Installers and maintenance personal How many hours of on job learning are required for an apprenticeship program each year - ANSWER-2,000 hours AC Voltage Tag Colors Class 00 - ANSWER-Beige tag 500 volts AC Voltage Tag Colo...
    (0)
  • $7.99
  • + learn more
Residential Electrician Exam #2 || Questions and Answer 100% Accurate
  • Residential Electrician Exam #2 || Questions and Answer 100% Accurate

  • Exam (elaborations) • 13 pages • 2024
  • Available in package deal
  • Residential Electrician Exam #2 || Questions and Answer 100% Accurate Residential Electrician Exam #2 || Questions and Answer 100% Accurate The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches - ANSWER-C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) ...
    (0)
  • $11.49
  • + learn more
Residential Electrician Exam #1 || Questions and Answers 100% Correct
  • Residential Electrician Exam #1 || Questions and Answers 100% Correct

  • Exam (elaborations) • 11 pages • 2024
  • Available in package deal
  • Residential Electrician Exam #1 || Questions and Answers 100% Correct Residential Electrician Exam #1 || Questions and Answers 100% Correct Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only - ANSWER-A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) swi...
    (0)
  • $10.49
  • + learn more
Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+
  • Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+ The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) bathrooms D: bathrooms Ref: 240.24(E) The MAXIMUM number of groun...
    (0)
  • $10.09
  • + learn more
Residential Electrician Exam #4 Questions And Answers
  • Residential Electrician Exam #4 Questions And Answers

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • When a single branch-circuit with an equipment grounding conductor is supplying a detached garage from a house, what, if any, additional grounding electrode(s) is/are required at the garage? a) A ground rod and underground metal water pipe. b) A metal underground water pipe only. c) A metal underground water pipe and building steel, if available. d) No additional electrodes are required. - Answer-D: No additional electrodes are required. Ref: 250.32(A), Ex. The point of attachment of a se...
    (0)
  • $7.99
  • + learn more
Residential Electrician Exam #3 Questions And Answers Rated A+
  • Residential Electrician Exam #3 Questions And Answers Rated A+

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • What is the MAXIMUM allowable cord length for the cord supplying a cord-and-plug connected dishwasher installed under a kitchen counter in a dwelling unit? a) 11⁄2 feet b) 2 feet c) 3 feet d) 4 feet - Answer-D: 4 feet Ref: 422.16(B)(2)(2) What is the MINIMUM size copper SE cable with type THHW insulation that may be used as ungrounded, service-entrance phase conductors for a 150 ampere-rated, 120/240-volt, singlephase, residential service? a) 1/0 AWG b) 1 AWG c) 2 AWG d) 3 AWG - A...
    (0)
  • $7.99
  • + learn more
Residential Electrician Exam #1Complete Questions With 100% Correct Answers.  Graded A+
  • Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Graded A+

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) switched receptacles for cord-connected incandescent luminaires b) permanently...
    (0)
  • $9.59
  • + learn more
Residential Electrician Exam #1 questions and answers all are correct graded A+
  • Residential Electrician Exam #1 questions and answers all are correct graded A+

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only - Answer-A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) switched receptacles for cord-connected incandescent luminaires b) permanently installed incandescent luminaires c) ceiling fans with luminaires ...
    (0)
  • $7.99
  • + learn more
Residential Electrician Exam #1 Questions and Answers 100% Correct
  • Residential Electrician Exam #1 Questions and Answers 100% Correct

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • Residential Electrician Exam #1 Questions and Answers 100% Correct Residential Electrician Exam #1 Questions and Answers 100% Correct Residential Electrician Exam #1 Questions and Answers 100% Correct Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only - ANSWER-A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, ge...
    (0)
  • $9.99
  • + learn more
Residential Electrician Exam #2 questions with correct answers
  • Residential Electrician Exam #2 questions with correct answers

  • Exam (elaborations) • 9 pages • 2023
  • Available in package deal
  • The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches CORRECT ANSWER C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) bathrooms CORRECT ANSWER D: bathrooms Ref: 240.24(E) The MAXIMUM number of grounded conductors allowed to be terminated in an individu...
    (0)
  • $14.49
  • + learn more