Billranker
On this page, you find all documents, package deals, and flashcards offered by seller BillRanker.
- 7118
- 0
- 265
Community
- Followers
- Following
60 Reviews received
7386 items
ACI Certification Concrete Field Testing Technician Grade 1 questions with correct answers
ACI Certification Concrete Field Testing Technician Grade 1 questions with correct answers
- Exam (elaborations)
- • 4 pages •
ACI Certification Concrete Field Testing Technician Grade 1 questions with correct answers
ACI Certification questions with correct answers
ACI Certification questions with correct answers
- Exam (elaborations)
- • 2 pages •
ACI Certification questions with correct answers
ACI Certification Exam questions with correct answers.
ACI Certification Exam questions with correct answers.
- Exam (elaborations)
- • 8 pages •
ACI Certification Exam questions with correct answers.
ACI Certification Concrete Field Technician Testing Grade 1 questions with correct answers
ACI Certification Concrete Field Technician Testing Grade 1 questions with correct answers
- Exam (elaborations)
- • 4 pages •
ACI Certification Concrete Field Technician Testing Grade 1 questions with correct answers
ACI Concrete Field Testing Technician Grade 1 Study Guide questions with correct answers.
ACI Concrete Field Testing Technician Grade 1 Study Guide questions with correct answers.
- Exam (elaborations)
- • 11 pages •
ACI Concrete Field Testing Technician Grade 1 Study Guide questions with correct answers.
ACI Written Exam questions with correct answers
ACI Written Exam questions with correct answers
- Exam (elaborations)
- • 15 pages •
ACI Written Exam questions with correct answers
ACI Test questions with correct answers.
ACI Test questions with correct answers.
- Exam (elaborations)
- • 10 pages •
ACI Test questions with correct answers.
ACI Concrete Field Testing Technician - Grade I questions with correct answers
Grade I questions with correct answers 
The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. Answer 77mm /3in. 
 
The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. Answer 0.5 C / +-1F / 0-50 Decrees C 
 
The temp. measuring device shall be verified __, or whenever there is a question of __. Ans...
- Exam (elaborations)
- • 8 pages •
Grade I questions with correct answers 
The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. Answer 77mm /3in. 
 
The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. Answer 0.5 C / +-1F / 0-50 Decrees C 
 
The temp. measuring device shall be verified __, or whenever there is a question of __. Ans...
ACI Certification- Concrete Field Testing Technician Grade 1 CP-1 questions with correct answers
ASTM C1064 Answer Standard Test Method For Temperature of Freshly Mixed Hydraulic-Cement Concrete 
 
The sensor of the temperature measuring device shall be submerged a minimum of ______ inches into the freshly mixed concrete. Answer 3" 
 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to ± ______ °F throughout a range of ____________. Answer 1 degree, 30 degrees to 120 degrees 
 
The temperature measuring device shall be calibrated _...
- Exam (elaborations)
- • 20 pages •
ASTM C1064 Answer Standard Test Method For Temperature of Freshly Mixed Hydraulic-Cement Concrete 
 
The sensor of the temperature measuring device shall be submerged a minimum of ______ inches into the freshly mixed concrete. Answer 3" 
 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to ± ______ °F throughout a range of ____________. Answer 1 degree, 30 degrees to 120 degrees 
 
The temperature measuring device shall be calibrated _...
ACI Concrete Field Testing Technician- Grade I questions with correct answers
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. Answer 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. Answer 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
 
The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. Answer...
- Exam (elaborations)
- • 17 pages •
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. Answer 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. Answer 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
 
The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. Answer...
Milady Final Review 100 Question Test with correct answers
MS Class D License Test questions with correct answers
MN Life and Health Insurance Exam questions with correct answers
RADT 1001 questions with correct answers
CP-FS study guide questions with correct answers