AMAIZING EDUCATION WORLD
GET ALL KIND OF EXAMS ON THIS PAGE ,COMPLETE TEST BANKS,SUMMARIES,STUDY GUIDES,PROJECT PAPERS,ASSIGNMENTS,CASE STUDIES, YOU CAN ALSO COMMUNICATE WITH THE SELLER FOR ANY PRE-ORDER,ORDER AND ETC
- 1712
- 0
- 158
Community
- Followers
- Following
15 Reviews received
18 items
Operation of Wastewater Treatment prep complete exam questions and verified answers 2024/2025
Operation of Wastewater Treatment prep 
complete exam questions and verified 
answers 2024/2025 
An Imhoff cone is used to measure________solids. 
A. suspended 
B. colloidal 
C. volatile 
D. settleable - CORRECT ANSWER-D. settleable 
(Operation of Wastewater Treatment Plants, Volume 1 
by Kenneth D. Kerri) 
A _____ flume is widely used for measuring wastewater flow. - CORRECT ANSWERParshall 
(Operation of Wastewater Treatment Plants, Volume 1 
by Kenneth D. Kerri) 
Velocity of flow in a gri...
- Package deal
- Exam (elaborations)
- • 21 pages •
Operation of Wastewater Treatment prep 
complete exam questions and verified 
answers 2024/2025 
An Imhoff cone is used to measure________solids. 
A. suspended 
B. colloidal 
C. volatile 
D. settleable - CORRECT ANSWER-D. settleable 
(Operation of Wastewater Treatment Plants, Volume 1 
by Kenneth D. Kerri) 
A _____ flume is widely used for measuring wastewater flow. - CORRECT ANSWERParshall 
(Operation of Wastewater Treatment Plants, Volume 1 
by Kenneth D. Kerri) 
Velocity of flow in a gri...
Waste Water Operator class C exam 2024/2025 Review Questions and Answers correct verified
Waste Water Operator class C exam 
2024/2025 Review Questions and 
Answers correct verified 
When Chlorine is combined with water what type of pipe should be used? 
A. Ductile iron 
B. Asbestos concrete 
C. PVC 
D. Carbon Steel - CORRECT ANSWER-C. PVC 
A good settling sludge would consist of what type of protozoa? 
A. Rotifers and nematodes 
B. Amoebas and Flagellates 
C. Stalked ciliates and mastagoria 
D. Free swimmers and stalk ciliates - CORRECT ANSWER-D. Free swimmers and stalk 
ciliates...
- Package deal
- Exam (elaborations)
- • 17 pages •
Waste Water Operator class C exam 
2024/2025 Review Questions and 
Answers correct verified 
When Chlorine is combined with water what type of pipe should be used? 
A. Ductile iron 
B. Asbestos concrete 
C. PVC 
D. Carbon Steel - CORRECT ANSWER-C. PVC 
A good settling sludge would consist of what type of protozoa? 
A. Rotifers and nematodes 
B. Amoebas and Flagellates 
C. Stalked ciliates and mastagoria 
D. Free swimmers and stalk ciliates - CORRECT ANSWER-D. Free swimmers and stalk 
ciliates...
Treatment 2 Wastewater Operator certification Study Guide Exam GradedA
Treatment 2 Wastewater Operator 
certification Study Guide Exam GradedA 
General Wastewater Treatment: 
What is the pressure head caused by? - CORRECT ANSWER-Water elevation 
General Wastewater Treatment: 
What color should the piping be that contains reclaimed water? - CORRECT ANSWERpurple 
General Wastewater Treatment: 
What is the term for the height to which a column of water will rise in a well. - 
CORRECT ANSWER-piezometric surface 
General Wastewater Treatment: 
In general, what is the...
- Package deal
- Exam (elaborations)
- • 27 pages •
Treatment 2 Wastewater Operator 
certification Study Guide Exam GradedA 
General Wastewater Treatment: 
What is the pressure head caused by? - CORRECT ANSWER-Water elevation 
General Wastewater Treatment: 
What color should the piping be that contains reclaimed water? - CORRECT ANSWERpurple 
General Wastewater Treatment: 
What is the term for the height to which a column of water will rise in a well. - 
CORRECT ANSWER-piezometric surface 
General Wastewater Treatment: 
In general, what is the...
Waste Water Operator Treatment 1 Certification Study Guide Grade 1 Q&A
Waste Water Operator Treatment 1 
Certification Study Guide Grade 1 Q&A 
WasteWater Sources & Characteristics: 
What is the most common reason for a wastewater to contain intermittent large amounts 
of sand, gravel, and grit? - CORRECT ANSWER-storm events 
WasteWater Sources & Characteristics: 
Combined wastewater is defined as - CORRECT ANSWER-sanitary wastewater and 
stormwater runoff 
WasteWater Sources & Characteristics: 
In general, the solids content in wastewater is about - CORRECT ANSW...
- Package deal
- Exam (elaborations)
- • 12 pages •
Waste Water Operator Treatment 1 
Certification Study Guide Grade 1 Q&A 
WasteWater Sources & Characteristics: 
What is the most common reason for a wastewater to contain intermittent large amounts 
of sand, gravel, and grit? - CORRECT ANSWER-storm events 
WasteWater Sources & Characteristics: 
Combined wastewater is defined as - CORRECT ANSWER-sanitary wastewater and 
stormwater runoff 
WasteWater Sources & Characteristics: 
In general, the solids content in wastewater is about - CORRECT ANSW...
Final Complete study guide for wastewater practice exam 2024/2025
Final Complete study guide for 
wastewater practice exam 2024/2025 
Odors occur when treatment becomes - CORRECT ANSWER-Anaerobic 
What should an operator do before entering a manhole - CORRECT ANSWER-Test for 
all hazardous gases and oxygen levels and ventilate the manhole before entering 
What treatment devices is commonly used to separate and remove large solids from 
raw wastewater - CORRECT ANSWER-a mechanically raked bar screen 
What diseases are caused by pathogenic organisms that may ...
- Package deal
- Exam (elaborations)
- • 2 pages •
Final Complete study guide for 
wastewater practice exam 2024/2025 
Odors occur when treatment becomes - CORRECT ANSWER-Anaerobic 
What should an operator do before entering a manhole - CORRECT ANSWER-Test for 
all hazardous gases and oxygen levels and ventilate the manhole before entering 
What treatment devices is commonly used to separate and remove large solids from 
raw wastewater - CORRECT ANSWER-a mechanically raked bar screen 
What diseases are caused by pathogenic organisms that may ...
The Wastewater Operator Treatment 2 Final Exam 2024/2025
The Wastewater Operator Treatment 2 
Final Exam 2024/2025 
Liftstations at a treatment plant or those which discharge directly to a treatment plant 
with an average flow greater than 0.1 MGD shall have three or more pumps or have 
automatically controlled variable capacity pumps, these pumps should be adjusted to 
actual flow conditions and controlled to operate so as to: - CORRECT ANSWERMinimize surges in the treatment in the treatment units. 
In the contact stabilization system of activat...
- Package deal
- Exam (elaborations)
- • 5 pages •
The Wastewater Operator Treatment 2 
Final Exam 2024/2025 
Liftstations at a treatment plant or those which discharge directly to a treatment plant 
with an average flow greater than 0.1 MGD shall have three or more pumps or have 
automatically controlled variable capacity pumps, these pumps should be adjusted to 
actual flow conditions and controlled to operate so as to: - CORRECT ANSWERMinimize surges in the treatment in the treatment units. 
In the contact stabilization system of activat...
Waste Water Operator Level 1 Exam Prep 2024/2025
Waste Water Operator Level 1 Exam 
Prep 2024/2025 
In the activated sludge process, some of the activated sludge must be wasted to... 
A. Prevent excessive solid buildup 
B. Prevent clogging of the sludge return line 
C. Prevent overloading of sludge return pumps 
D. Increase digester gas production - CORRECT ANSWER-A. Prevent excessive solid 
buildup 
The best operating strategy for feeding primary sludge to an anaerobic digester is to 
feed... 
A. Several time a day 
B. Large quantities onc...
- Package deal
- Exam (elaborations)
- • 8 pages •
Waste Water Operator Level 1 Exam 
Prep 2024/2025 
In the activated sludge process, some of the activated sludge must be wasted to... 
A. Prevent excessive solid buildup 
B. Prevent clogging of the sludge return line 
C. Prevent overloading of sludge return pumps 
D. Increase digester gas production - CORRECT ANSWER-A. Prevent excessive solid 
buildup 
The best operating strategy for feeding primary sludge to an anaerobic digester is to 
feed... 
A. Several time a day 
B. Large quantities onc...
Wastewater Treatment Operator Certification Test 2 final study guide 2024/2025
Wastewater Treatment Operator 
Certification Test 2 final study guide 
2024/2025 
What is the typical BOD removal efficiency in a primary clarifier? 
A) 10 to 15% 
B) 40 to 60% 
C) 20 to 50% 
D) 95 to 99% - CORRECT ANSWER-C) 20 to 50% (v.1 pg 129) 
What does the "F" in F/M ratio represent? 
A) The microorganism population in the aeration tank 
B) The amount of filamentous bacteria in the activated sludge process 
C) The MLVSS in the aeration tank 
D) The food for the microorganisms flowing i...
- Package deal
- Exam (elaborations)
- • 15 pages •
Wastewater Treatment Operator 
Certification Test 2 final study guide 
2024/2025 
What is the typical BOD removal efficiency in a primary clarifier? 
A) 10 to 15% 
B) 40 to 60% 
C) 20 to 50% 
D) 95 to 99% - CORRECT ANSWER-C) 20 to 50% (v.1 pg 129) 
What does the "F" in F/M ratio represent? 
A) The microorganism population in the aeration tank 
B) The amount of filamentous bacteria in the activated sludge process 
C) The MLVSS in the aeration tank 
D) The food for the microorganisms flowing i...
BICSI Installer 2 study Review Technician Exam Questions and Answers 2024
BICSI TECHNICIAN Review Test Exam Guide with verified solutions 2024
BIOS 251 Exam 3 Week 8 final test exam questions with verified answers
Corporals Course Study Set Exam Latest Updated
2023-2024 15-HR NATIONAL USPAP COURSE COMPLETE STUDY SET RETAKE EXAM
Larger Print size needed, Gap between Question and Answer, Some had multiple answers not identified. Pleas