NETA ETT Certified Level 3 Complete Test Questions 2024. A newly installed 4160V emergency generator has an insulation resistance value of 150 Megohms after one minute with an equipment temperature of 32 degrees C. Is this value acceptable per NETA standards? No NETA ATS-2017 Table 100.11 ...

[Mostrar más]

Vista previa 4 fuera de 96  páginas

  • 29 de marzo de 2024
  • 96
  • 2023/2024
  • Examen
  • Preguntas y respuestas
  • NETA.
  • NETA.
avatar-seller
NETA ETT Certified Level 3
A newly installed 4160V emergency generator has an insulation resistance value of 150 Megohms after one minute with an equipment temperature of 32 degrees C. Is this value acceptable per NETA standards?
No
NETA ATS-2017 Table 100.11
https://testguy.net/content/240-Insulation-Resistance-Test-Values
Know the NETA-ATS Insulation Resistance tables
Which test method measures Hydrolyzable Flouride content in SF6 gas?
ASTM D2284
[Standard Test Method for Acidity of Sulfur Hexafluoride]
NETA ATS-2017 Table 100.13
Know the ASTM test names what what they test Brainpower
Read More
Previous
Play
Next
Rewind 10 seconds
Move forward 10 seconds
Unmute
0:01
/
0:15
Full screen
The operating speed of a protective relay is dependent on:
* Spring Tension
* Armature core air gap
* Rate of flux built up
https://en.wikipedia.org/wiki/
Protective_relay#Types_according_to_construction
This was originally a 'not question'. This list is not necessarily conclusive. It's simply the 'incorrect' answers to the 'not question'. According to IEEE C57.106, which test is recommended for routine acceptance of new, unprocessed oil from a supplier for use in circuit breakers?
ASTM D877
[Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes]
https://hvtechnologies.com/which-oil-testing-standard-should-you-choose-to-
determine-dielectric-breakdown-voltage/
Know IEEE C57 information. Know ASTM tests and definitions
Meter Sockets and meter disconnect switches should generally be connected on what side of a service disconnecting means?
The line side
NFPA 70-2017 Article 230.82(3)
https://www.electricallicenserenewal.com/Electrical-Continuing-Education-
Courses/NEC-Content.php?sectionID=40.0
This was originally a True/False statement question. The answer stated that the load side is wrong. The reference above seems to imply that meter sockets and meter disconnect switches should generally be connected on the line side.
Know NFPA 70
What size neutral resistor would be required to limit the fault current of a 13,800-480Y/277V 1500kVA Transformer to 5A?
55.4
Know Ohm's Law. 277 V / 5A = 55.4 ohms
I believe that since this is dealing with the neutral, Line-Neutral voltage (277 V) should be used in the formula. 5 A on the line will also be 5A on the windings since the transformer configuration is a Wye configuration. I also believe that the impedance of the transformer is negligible in this calculation since it isn't mentioned in the question and presumably would only limit the fault current further.
Correcting the power factor of three-phase loads normally involves adding (capacitance, inductance) in (series, parallel)
capacitance in parallel
http://archive.is/WOiLd

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ROSEGRADES. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for 12,84 €. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
12,84 €  4x  vendido
  • (0)
  Añadir