CT TEST REVIEW (TEST Q'S AND A'S FOR CT REGISTRY PREP. THIS IS FROM THE BOOK "COMPUTED TOMOGRAPHY FOR TECHNOLOGISTS: EXAM REVIEW" BY LOIS E ROMANS. PUBLISHED BY WOLTERS KLUWER, LIPPINCOTT WILLIAMS AND WILKINS.)

 13 vistas  0 veces vendidas
  • Grado
  • CT REGISTRY
  • Institución
  • CT REGISTRY

CT TEST REVIEW (TEST Q'S AND A'S FOR CT REGISTRY PREP. THIS IS FROM THE BOOK "COMPUTED TOMOGRAPHY FOR TECHNOLOGISTS: EXAM REVIEW" BY LOIS E ROMANS. PUBLISHED BY WOLTERS KLUWER, LIPPINCOTT WILLIAMS AND WILKINS.) Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT e...

[Mostrar más]

Vista previa 4 fuera de 43  páginas

  • 18 de agosto de 2024
  • 43
  • 2024/2025
  • Examen
  • Preguntas y respuestas
  • CT REGISTRY
  • CT REGISTRY
avatar-seller
CT TEST REVIEW (TEST Q'S AND A'S FOR CT
REGISTRY PREP. THIS IS FROM THE BOOK
"COMPUTED TOMOGRAPHY FOR
TECHNOLOGISTS: EXAM REVIEW" BY LOIS E
ROMANS. PUBLISHED BY WOLTERS KLUWER,
LIPPINCOTT WILLIAMS AND WILKINS.)
Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination?

A. Topogram

B. Scout

C. Scanogram

D. Spiral - Correct Answer D. Spiral



The ability of a system to differentiate, on the image, objects with similar densities is known as:

A. High contrast resolution

B. Low contrast resolution

C. Spatial resolution

D. Temporal resolution - Correct Answer B. Low contrast resolution



Each two dimensional square of data that make up the CT image is called a:

A. Pixel

B. Voxel

C. Matrix

D. Fragment - Correct Answer A. Pixel



How many pixels are contained in a 1,024 matrix image? A. 1,024

B. 2,048

C. 262,144

D. 1,048,576 - Correct Answer D. 1,048,576



Beam attenuation can be defined as:

A. The phenomenon by which artifacts result when lower energy photons are preferentially
absorbed, leaving only higher-intensity photons to strike the detector array.

,B. Xray energy that is produced from bombarding a substance with fast moving electrons.

C. The ability of the detector to capture transmitted photons and change them to electronic signals.

D. The phenomenon by which an xray beam passing through a structure is decreased in intensity or
amount because of absorption and interaction with matter. - Correct Answer D. The phenomenon by
which an xray beam passing through a structure is decreased in intensity or amount because of
absorption and interaction with matter.



Which of the following is a low attenuation structure:

A. Iodine filled aorta

B. Rib

C. Trachea

D. Calcified arteries - Correct Answer C. Trachea



An object is slightly less dense than water. What is the expected hounsfield measurement?

A. -940

B. -10

C. 50

D. 850 - Correct Answer B. -10



Why does the administration of iodinated contrast media result in an enhanced image?

A. Iodinated contrast material increases the ability of the enhanced structure to attenuate the xray
beam.

B. Iodinated contrast material decreases the average photon energy of the xray beam; therefore
more photons are absorbed by the patient.

C. The administration of contrast material results in a smaller pixel, thereby increasing spatial
resolution, which results in an enhanced image.

D. - Correct Answer A. Iodinated contrast material increases the ability of the enhanced structure to
attenuate the xray beam.



The xray beam sources for CT produce xray energy that is polychromatic. This means:

A. When viewed by the naked eye, the beam exhibits many different colors.

B. It produce, as a byproduct, a substance known as polychlorinated biphenyl.

C. Photons contained in the beam are all of the same wavelength.

,D. The beam comprises photons with varying energies. - Correct Answer D. The beam comprises
photons with varying energies.



An object that appears on the image but is not present in the object scanned is called a/n:

A. Artifact

B. Anomaly

C. Shadow

D. Ghost - Correct Answer A. Artifact



Which is an advantage of filtering the xray beam?

A. Filtering reduces the anode heat load

B. A filtered beam produces images with substantially less quantum mottle

C. Filtering the beam prevents energy from being converted to heat, therefore 100% of the energy is
converted to xrays.

D. Filtering reduces the radiation dose to the patient. - Correct Answer D. Filtering reduces the
radiation dose to the patient



Scan thickness is primarily important for the part it plays in:

A. Noise reduction

B. The contrast scale

C. Detector aperture opening

D. Volume averaging - Correct Answer D. Volume averaging



You are working with the radiologist to establish examination protocols for your department. Which
of the following is a logical consideration when determining an appropriate slice thickness for studies
of the internal auditory canal?

A. Because the auditory ossicles are quite small, a thin slice will be necessary to reduce the chance
that volume averaging will obscure their appearance on the image.

B. The appropriate slice thickness will vary considerably from patient to patient. Therefore, each
technologist should be free to adjust the slice thickness as he or she deems necessary for the
particular patient.

C. A slice thickness of 5 to 7mm is adequate because the structures of interest are not particularly
small and the examination is most often ordered as a screening study for asymptomatic patients.

, D. The thickest slice available should be used to reduce the radiation dose to the corneas. - Correct
Answer A. Because the auditory ossicles are quite small, a thin slice will be necessary to reduce the
chance that volume averaging will obscure their appearance on the image.



How many CT numbers are assigned to each pixel in the image matrix?

A. One half the number of all values recorded from the detector array

B. One

C. The number of HU per pixel is one tenth the display field of view

D. Two values for a 256 matrix; 4 values for a 512 matrix - Correct Answer B. One



Which is another name for raw data?

A. Image data

B. Scan data

C. Reconstructed data

D. Displayed data - Correct Answer B. Scan data



When in the anatomic position, the arms are:

A. raised above the head, palms backwards

B. crossed over the chest, palms on opposite shoulders

C. down by the sides, palms forward

D. by the sides, elbows bent, palms backward and resting on hips - Correct Answer C. down by the
sides, palms forward



Which of the following components is NOT housed within the gantry?

A. Three phase generator

B. High-frequency generator

C. Slip rings

D. Xenon gas detectors - Correct Answer A. Three phase generator



The power capacity of the generator is listed in:

A. milliamperes (mA)

B. thousand heat units (KHU)

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Winfred. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for 10,25 €. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender

Vistos recientemente


10,25 €
  • (0)
  Añadir