100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada
logo-home
CT REGISTRY STUDY GUIDE QUESTIONS WITH CORRECT ANSWERS FOR GARANTEED PASS 9,82 €   Añadir al carrito

Examen

CT REGISTRY STUDY GUIDE QUESTIONS WITH CORRECT ANSWERS FOR GARANTEED PASS

 9 vistas  0 veces vendidas
  • Grado
  • CT REGISTRY
  • Institución
  • CT REGISTRY

CT REGISTRY STUDY GUIDE QUESTIONS WITH CORRECT ANSWERS FOR GARANTEED PASS What determines how much and what section of the collected raw data is used to create an image - Correct Answer Display field of view The "string of beads" artifact is most closely associated with which of the following? ...

[Mostrar más]

Vista previa 2 fuera de 11  páginas

  • 18 de agosto de 2024
  • 11
  • 2024/2025
  • Examen
  • Preguntas y respuestas
  • CT REGISTRY
  • CT REGISTRY
avatar-seller
CT REGISTRY STUDY GUIDE QUESTIONS
WITH CORRECT ANSWERS FOR GARANTEED
PASS
What determines how much and what section of the collected raw data is used to create an image -
Correct Answer Display field of view



The "string of beads" artifact is most closely associated with which of the following? - Correct Answer
Maximum intensity projection images



A patient has a severe vagal reaction to iodinated contrast material that includes bradycardia should
be given a treatment of - Correct Answer *treatment includes increasing blood pressure with IV
fluids

*intravenous administration of atropine to block vagal stimulation of the heart



An MDCT image is reconstructed using a 512x512 matrix and a display field of view of 44 cm. If the
detector collimation is set to a section width of 2.5 mm what is the volume of each voxel - Correct
Answer How to solve: The linear dimension of the pixel must first be calculated by dividing the DFOV,
in mm, by the matrix. This linear pixel dimension is squared to yield the pixel area in mm^2. The
volume of the voxel may be calculated by multiplying the pixel area by the section width

step 1. 44 cm/ 512 =0.0859

step 2. 0.0859*2.5 mm = 0.2148

step 3. move the decimal point =2.15 mm^3



For a particular CT scanner's beam quality, the linear attenuation coefficient for water is 0.20 cm-1
and for a certain tumor is 0.21 cm-1. What is the CT number of the tumor? - Correct Answer
Equation (.21-.20/.21) × 1000= 50



A CT system measures the average linear attenuation coefficient of a voxel of tissue to be 0.189. The
linear coefficient of water for this scanner is 0.181. The CT number assigned to the pixel representing
this tissue is - Correct Answer 44 HU

use equation above



A CT scanner capable of producing an image that is a perfect reproduction of the actual anatomic
section is said to have an MTF modulator transfer function of - Correct Answer 1

, For an increase from 200 mA to 400 mA in a CT exam, the result would be to - Correct Answer
increase low contrast resolution



The major controlling factor of exam quality for coronary CTA is - Correct Answer patients heart
rate... 65-70 beats per minute yield the best results



What is the atomic number of xenon gas? - Correct Answer 54



The exaggeration of displayed calcification within the coronary arteries during cardiac MDCT study is
referred to as - Correct Answer blooming

- the potential overestimation of vessel calcification due to partial volume artifact



a wide window setting (1500) or improving spatial resolution could help mitigate this effect



Which of the following section widths would cause the greatest amount of partial volume averaging



A. 1 mm

B. 3 mm

C. 5 mm

D. 10 mm - Correct Answer D. 10 mm



- Large section widths result in long voxel lengths with possibly several tissue types accounted for
within the voxel. When a CT number is assigned to the representative pixel, the density of all the
tissue types is averaged, yielding one attenuation coefficient. Narrow section widths tend to reduce
partial volume effect



What reduces partial volume effect? - Correct Answer narrow section widths



Patient is having a severe vagal reaction to contrast including brachycardia and hypotension.. what
should be done? - Correct Answer Iv fluids to raise blood pressure

atrophine administration to block vagal stimulation of the heart.



What type of reconstruction technique was used in the first CT scanners? - Correct Answer Iterative
form of reconstruction

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Winfred. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for 9,82 €. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
9,82 €
  • (0)
  Añadir