Mosby CT Registry Review Questions and Answers 2024 What is the smallest component of a digital image pixel How many CT numbers are assigned to each pixel in the image matrix? One In a CT image, the CT number Of a material is dependent on its linear attenuation coefficient ...

[Mostrar más]

Vista previa 4 fuera de 46  páginas

  • 19 de septiembre de 2024
  • 46
  • 2024/2025
  • Examen
  • Preguntas y respuestas
  • CT Registry
  • CT Registry
avatar-seller
Mosby CT Registry Review Questions
and Answers 2024

What is the smallest component of a digital image - answer pixel

How many CT numbers are assigned to each pixel in the image matrix? - answer One

In a CT image, the CT number - answer Of a material is dependent on its linear
attenuation coefficient

Each two-dimensional square of data that make up the CT image is called a - answer
pixel

What is an element of the digital image - answer pixel

Which of the following influences the spatial resolution in cardiac CT imaging -
answer*detector size
*reconstruction interval
*pitch

As patient motion increases spatial resolution decreases - answer TRUE

Which is an advantage of using a small focal spot - answer increased spatial resolution

Increasing the CT image matrix from 256x256 to 512x512 will likely improve? - answer
High-contrast spatial resolution

The practical limiting spatial resolution of a CT scanner is 3.6 lp/cm. What size object
does this correspond to? - answer1.4 mm

Use of a bone filter, as opposed to a soft tissue filter, to reconstruct CT images would
likely improve? - answer Spatial resolution

The spatial resolution of a typical CT scanner is on the order of? - answer1 mm

A 512 x 512 matrix CT image over a 30-cm field of view could show a spatial resolution
of no better than ? lp/cm? - answer8.5

When comparing a 512x512 matrix to a 1024x1024 matrix, the 1024x1024 matrix? -
answer Contains four times as many pixels: 1024 x 1024 =1048576 then 512 x 512=
262144...then divide 1048576 /262144 = 4

,High contrast spatial resolution and low contrast resolution are typically measured
baseline and? thereafter - answer Biannually

To improve the high contrast spatial resolution of a CT study, one would increase _____
while keeping all other factors the same. - answer Matrix size (128x128 to 512x512)

A radiologist wants to improve the high-contrast spatial resolution of anatomy which
he/she is examining by CT. The change which would best lead to this improvement is -
answer Increase the matrix size

To improve the high-contrast spatial resolution of a CT study, one could increase ?
while keeping all other factors the same? - answer Matrix size

A voxel contains 25% air, 50% water and 25% bone. The CT number for this voxel
would be expected to be _____ HU? - answer0

How many pixels are contained in a 1,024 matrix image? – answer D. 1,048,576

MATH 1024 X1024

It is located in a matrix and is a two dimensional representation of a voxel - answer pixel

When CT numbers are calculated for voxels (volume elements) of tissue what is
assigned the calculated number and a subsequent shade of gray - answer pixel

What is defined as a picture element or the smallest component of the digital image -
answer pixel

A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter FOV.
Each pixel is approximately _____ mm on a side. - answer0.6 equation:
30cm/512= .058cm convert to mm and its .58 which is approximately 0.6

The ability of a system to define small objects distinctly is referred to as which of the
following? - answer spatial resolution

Which of the following terms is/are commonly used to describe a CT scanner's ability to
differentiate objects with similar linear attenuation coefficients - answer*spatial
resolution
*sensitivity

Which of the following factors have an affect on contrast resolution - answer*patient size
*slice thickness
*pixel size
*mAs/dose

,As mAs/dose increases contrast resolution decreases - answer FALSE

As mAs/dose increases contrast resolution INCREASES - answer TRUE

The ability of a CT scanner to accurately image objects with similar densities is termed -
answer*contrast resolution
*sensitivity

Which of the following has a direct relationship on increasing contrast resolution -
answer*mAs/dose increase
*Slice thickness

For a particular CT scanner's beam quality, the linear attenuation coefficient for water is
0.20 cm-1 and for a certain tumor is 0.21 cm-1. What is the CT number of the tumor? -
answer50. Equation (.21-.20/.21) × 1000= 50

A CT scanner with poor contrast resolution or low sensitivity has difficulty separating -
answer tissues whose linear attenuation coefficients are nearly equal

What is the basic physical quantity being measured by a CT system - answer Linear
attenuation coefficient

Assume the linear attenuation coefficient is 0.20 cm-1 for water and 0.40 cm-1 for tissue
within a given voxel. What is the CT number in Hounsfield units for the pixel
representing this voxel? - answer+1,000....Equation { (.4-.2) /.2} x 1000

What fraction of monoenergetic x-rays will be absorbed by a 20-cm thick material
having a linear attenuation coefficient of 0.05 cm-1? - answer0.63

The contrast resolution of CT is approximately ? % - answer0.3 to 0.6

This term describes the ability CT scanner to differentiate objects with MINIMAL
differences in attenuation coefficients - answer contrast resolution

What is the term for resolution of a CT scanner referred to as the system's ability to
differentiate objects with SIMILAR densities. - answer contrast resolution

In order to pass ACR CT accreditation, the CT scanner's adult head protocol must be
within - answer1.0

The QC test for the average CT number for water should be done - answer Daily

The following are all basic tenets of a QC program for computed tomography scanner -
answer*QC test must be conducted regularly
*Accurate record keeping
*all test results must be interpreted promptly

, Using the ACR CT accreditation phantom, module 3 is used to measure which of the
following - answerCT number uniformity

The following QC test should be done on a monthly basis - answerhigh contrast
resolution

The CT number at the center of a uniformly filled water phantom should ideally be -
answer0

The ACR CT accreditation phantom is designed to perform QC measurements of -
answer*positioning accuracy and light accuracy alignment only
*CT number accuracy and slice thickness only
*low contrast resolution, CT number uniformity, and high contrast resolution

The ACR tolerance limit for the CT number accuracy for water is - answer+-7HU or +-5
preferred

The test for the average CT number of water should be tested at - answer*acceptance
*daily

The ACR tolerance limit for the CT number uniformity is which of the following -
answerThe center CT number must be between plus or minus 7HU plus the abdomen
protocol must be used

To evaluate low contrast resolution, phantoms are scanned using different ? settings -
answermAs

For an increase from 200 mA to 400 mA in a CT exam, the result would be to -
answerIncrease low contrast resolution

This ability is also commonly referred to as the low contrast resolution or the sensitivity
of the CT scanner - answercontrast resolution

The major advantage of a CT scanner over a screen-film radiography system is -
answerBetter low contrast discrimination

For CT images, all of the following factors improve the visibility of large, low-contrast
lesions except? - answerSmaller pixel sizes

As the iodine concentration ? the viscosity of the substance will ? - answerincrease,
increase

A fluid with a high viscosity is relatively - answerthick and flows slowly

The viscosity of a solution may be changed by regulating - answertemperature

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for 17,68 €. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
17,68 €
  • (0)
  Añadir