[Mostrar más]Heat which causes a change in temperature of a substance is called; 
: Sensible Heat. 
heat added to substance without a rise in temperature; (example: liquid refrigerant to 
gas) this process is called? 
: Latent heat of vaporization. 
Heat added to the refrigerant in a vapor state after the evapo...
Vista previa 3 fuera de 16 páginas
Añadir al carritoHeat which causes a change in temperature of a substance is called; 
: Sensible Heat. 
heat added to substance without a rise in temperature; (example: liquid refrigerant to 
gas) this process is called? 
: Latent heat of vaporization. 
Heat added to the refrigerant in a vapor state after the evapo...
Upflow Furnace: 
: Is used to describe furnaces that stand upright and blow air upward. These 
systems are designed for first floor installation with attic ductwork or basement 
installation with ductwork positioned below the first floor. 
Low boy furnace: 
: Similar to Upflow except the furnace i...
Vista previa 2 fuera de 9 páginas
Añadir al carritoUpflow Furnace: 
: Is used to describe furnaces that stand upright and blow air upward. These 
systems are designed for first floor installation with attic ductwork or basement 
installation with ductwork positioned below the first floor. 
Low boy furnace: 
: Similar to Upflow except the furnace i...
Before working on an electric furnace the tech should 
: Review diagram, remove jewelry, and follow safety procedures. ALL OF THE 
ABOVE. 
A GFCI circuit breaker 
: detects current leaks to groound 
the conductor in an electric heat element is usually made of 
: Nichrome 
An example of resistive lo...
Vista previa 3 fuera de 17 páginas
Añadir al carritoBefore working on an electric furnace the tech should 
: Review diagram, remove jewelry, and follow safety procedures. ALL OF THE 
ABOVE. 
A GFCI circuit breaker 
: detects current leaks to groound 
the conductor in an electric heat element is usually made of 
: Nichrome 
An example of resistive lo...
The International Mechanical Code considers a "flammable Vapor" to be concentration 
of flammable constituents in the air which exceeds _____________ percent of its 
flammability limit. 
: 25% 
During installation or service of electrical controls, a digital multimeter set to voltage 
must be c...
Vista previa 3 fuera de 16 páginas
Añadir al carritoThe International Mechanical Code considers a "flammable Vapor" to be concentration 
of flammable constituents in the air which exceeds _____________ percent of its 
flammability limit. 
: 25% 
During installation or service of electrical controls, a digital multimeter set to voltage 
must be c...
using an ohmmeter, there is 120 VAC between high speed and ground wires, this 
indicates 
: open 
if temperature rise is too high... 
: increase fan speed 
how many of the 3 OSHA conditions defining confined spaces must be met 
: all 3 
what causes the temperature limit safety switch to shut off th...
Vista previa 2 fuera de 11 páginas
Añadir al carritousing an ohmmeter, there is 120 VAC between high speed and ground wires, this 
indicates 
: open 
if temperature rise is too high... 
: increase fan speed 
how many of the 3 OSHA conditions defining confined spaces must be met 
: all 3 
what causes the temperature limit safety switch to shut off th...
Heat which causes a change in temperature of a substance is called 
: Sensible Heat 
Heat added to a substance without a rise in temperature is called 
: Latent Heat 
Heat added to refrigerant in a vapor state after the evaporation process is called 
: Superheat 
A scroll compressor moved refrigeran...
Vista previa 3 fuera de 16 páginas
Añadir al carritoHeat which causes a change in temperature of a substance is called 
: Sensible Heat 
Heat added to a substance without a rise in temperature is called 
: Latent Heat 
Heat added to refrigerant in a vapor state after the evaporation process is called 
: Superheat 
A scroll compressor moved refrigeran...
Can cause a packaged HVAC unit to run high head pressure? 
: The condenser coil is dirty. 
Condenser coil fins are often damaged by: 
: Hail storms. 
Frequent pressure washing. 
Salt spray. 
Insufficient rinsing after cleaning coils with strong acids and bases. 
Water cooled air conditioning systems...
Vista previa 1 fuera de 2 páginas
Añadir al carritoCan cause a packaged HVAC unit to run high head pressure? 
: The condenser coil is dirty. 
Condenser coil fins are often damaged by: 
: Hail storms. 
Frequent pressure washing. 
Salt spray. 
Insufficient rinsing after cleaning coils with strong acids and bases. 
Water cooled air conditioning systems...
Current flow is 
: the flow of electrons in the circuit 
impedance is 
: opposition to alternating current flow 
like charges 
: repel each other 
Any material that will readily release electrons is called 
: a conductor 
the symbol for current is 
: I 
Which of the following materials would best be...
Vista previa 3 fuera de 16 páginas
Añadir al carritoCurrent flow is 
: the flow of electrons in the circuit 
impedance is 
: opposition to alternating current flow 
like charges 
: repel each other 
Any material that will readily release electrons is called 
: a conductor 
the symbol for current is 
: I 
Which of the following materials would best be...
Propane and Butane are _______ than air: 
: Heavier 
What will be the resistance in the circuit if the supply voltage is 30V and current flowing 
through the circuit is 5A 
: 6 ohms 
Temperature at which oil starts to produce a waxy substance that may interfere with the 
refrigeration system 
: Fl...
Vista previa 1 fuera de 3 páginas
Añadir al carritoPropane and Butane are _______ than air: 
: Heavier 
What will be the resistance in the circuit if the supply voltage is 30V and current flowing 
through the circuit is 5A 
: 6 ohms 
Temperature at which oil starts to produce a waxy substance that may interfere with the 
refrigeration system 
: Fl...
An instrument that measures potential differences between 2 points in an electrical 
circuit is called? 
A. potentiometer 
B. thermistor 
C. ohmeter 
D. voltmeter 
: voltmeter 
This device uses a thermal sensing bulb at the outlet of the evaporator to sense 
temperature and control superheat 
A. a...
Vista previa 4 fuera de 33 páginas
Añadir al carritoAn instrument that measures potential differences between 2 points in an electrical 
circuit is called? 
A. potentiometer 
B. thermistor 
C. ohmeter 
D. voltmeter 
: voltmeter 
This device uses a thermal sensing bulb at the outlet of the evaporator to sense 
temperature and control superheat 
A. a...
What is an SSU and what does it do? 
: It is a unit located on the side of the first which receives power (120 volts) before 
anything located within the furnace itself. It primarily consists of a switch and a fuse, and 
it is what allows for power to flow to the door switch. Opening the switch on...
Vista previa 2 fuera de 5 páginas
Añadir al carritoWhat is an SSU and what does it do? 
: It is a unit located on the side of the first which receives power (120 volts) before 
anything located within the furnace itself. It primarily consists of a switch and a fuse, and 
it is what allows for power to flow to the door switch. Opening the switch on...
A gas furnace is to be installed in a garage. The national standards require that the 
burners and ignition sources must be located ______ above the floor 
: 18 inches 
A good description of how a bi-metal fan switch operates the blower motor on a gas 
furnace is 
: Temperature on- temperature off...
Vista previa 3 fuera de 17 páginas
Añadir al carritoA gas furnace is to be installed in a garage. The national standards require that the 
burners and ignition sources must be located ______ above the floor 
: 18 inches 
A good description of how a bi-metal fan switch operates the blower motor on a gas 
furnace is 
: Temperature on- temperature off...
A separate and distinct ventilation or exhaust system shall be provided for _____? 
(A)noxious gases (B) corrosive fumes (C)flammable vapors (D) incompatible materials. 
: D. 505.1.2 In systems conveying flammable vapors, gases, or mists, the 
concentration shall not exceed 25 percent of the lower...
Vista previa 3 fuera de 22 páginas
Añadir al carritoA separate and distinct ventilation or exhaust system shall be provided for _____? 
(A)noxious gases (B) corrosive fumes (C)flammable vapors (D) incompatible materials. 
: D. 505.1.2 In systems conveying flammable vapors, gases, or mists, the 
concentration shall not exceed 25 percent of the lower...
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Stuvia is a marketplace, so you are not buying this document from us, but from seller ExamArsenal. Stuvia facilitates payment to the seller.
No, you only buy this summary for $23.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
45,681 summaries were sold in the last 30 days
Founded in 2010, the go-to place to buy summaries for 14 years now