100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada
logo-home
HVAC: EPA 608 Certification Study Guide 2023/2024 already graded A+ $9.99   Añadir al carrito

Examen

HVAC: EPA 608 Certification Study Guide 2023/2024 already graded A+

 11 vistas  0 veces vendidas
  • Grado
  • EPA certification
  • Institución
  • EPA Certification

HVAC: EPA 608 Certification Study Guide 2023/2024 already graded A+

Vista previa 2 fuera de 9  páginas

  • 30 de noviembre de 2023
  • 9
  • 2023/2024
  • Examen
  • Preguntas y respuestas
  • EPA certification
  • EPA certification
avatar-seller
HVAC: EPA 608 Certification Study Guide

Are there drop-in replacements for R-12 systems? Why or why not? - ANSNo because the new
refrigerants are incompatible with the oils and lubricants used in R-12 systems.

What type of oil is used in R-134a and what oils will it mix with? - ANSEster based oils and they
do not mix with other oils

What type of lubricant is used with HCFCs? - ANSAlkylbenzene lubricant

What is difference b/w ternary blend a azeotropic blend? - ANSTernary blends are three-part
mixtures whereas azeotropic blends are blends of two or more compounds that act like a single
compound.

What is the trait of a hygroscopic lubricant? - ANSIt absorbs (takes on) moisture

What is temperature glide and what type of blend won't have it? - ANSTemp. blend is the
difference between the dew point and the bubble point

Dew Point - ANSOccurs when saturation temp in evaporator causes refrigerant to change from
liquid to vapor

Bubble Point - ANSOccurs when saturation temp in condenser changes refrigerant from vapor
to liquid

Will the gases in a ternary blend leak at the same rate? Why or why not? - ANSNo because
different refrigerants in blend have different vapor pressures, causing them to leak at uneven
rates

Refrigeration Process - ANStransfer of heat from one place to another

Evaporator - ANSAbsorbs heat into system from space to be cooled. Absorption of heat causes
refrigerant to boil. Upon leaving, refrigerant changed to low pressure, low temperature vapor

Compressor - ANSTakes low pressure, low temp vapor and changes it to a high-temp,
high-pressure, superheated vapor and delivers it to the condenser

Condenser - ANSRejects heat from system and changes refrigerant from high-temp,
high-pressure vapor into high-pressure, high-temp liquid

Metering Device - ANSreduces pressure of refrigerant and changes the high-pressure,
high-temp liquid into low pressure, low temp liquid.

, Compound Gauge - ANSTypically blue and measures low pressure (psig) and vacuum (inHg).

High Pressure Gauge - ANSRed and measures high side (discharge) pressure. 0 to 500 psi

What does a compressor compress? - ANSVapor

Why will refrigerant migrate to the crankcase in a compressor? - ANSBecause of the vapor
pressure difference between refrigerant and oil

What color is the high pressure gauge? - ANSRed

What color is the low pressure gauge? - ANSBlue

What needs to happen if oil has been contaminated by burnout? - ANSTriple evacuate system,
install permanent filter-drier, conduct deep vacuum before recharging

What are three Rs of refrigeration? - ANSRecover, recycle, reclaim

Recover - ANSto remove any refrigerant in any condition from system and store in external
container without necessarily testing or processing in any way

Recycle - ANSTo clean refrigerant for immediate reuse by separating oil from refrigerant and
removing moisture and acidity from refrigerant by use of products like filter driers

Reclaim - ANSTo process refrigerant to level of new product specifications as determines by
chemical analysis

What standards must refrigerant recovery equipment meet and what components must all Type
I and Type II refrigerant systems have? - ANSEPA-approved equipment testing organization.
Service aperture or process stub

System-Dependent Devices - ANSCapture refrigerant with assistance of compressor and/or
pressure of refrigerant in appliances from which refrigerant is being recovered

Self-contained Devices - ANSHave independent means to draw refrigerant out of appliances

What is nitrogen and a filter-drier used for after recovery? - ANSUse nitrogen to flush debris out
of system after recovering refrigerant. Filter-drier should be installed to trap any debris that may
cause damage to new compressor

What must be done before starting an evacuation? - ANSRecover all refrigerant and attain the
mandated vacuum level

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Ashley96. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
$9.99
  • (0)
  Añadir