al - Answer-Current induced iby receiver coil. Also comes from the procession of protons in the patient. Chemical pre saturation - Answer-Selectively apply 90 degree pulse at frequency of tissue to be saturated. Moves fat or HBO 90 degrees. 2nd puse wider bandwidth moves both fat and water 90 d...

[Mostrar más]

Vista previa 2 fuera de 7  páginas

  • 29 de febrero de 2024
  • 7
  • 2023/2024
  • Examen
  • Preguntas y respuestas
  • MRI PHYSICS- Armrit
  • MRI PHYSICS- Armrit
avatar-seller
MRI PHYSICS - Armrit Test Signal - Answer -Current induced iby receiver coil. Also comes from the procession of protons in the patient. Chemical pre saturation - Answer -Selectively apply 90 degree pulse at frequency of tissue to be saturated. Moves fat or HBO 90 degrees. 2nd puse wider bandwidth moves both fat and water 90 degrees. One will be saturated so will not be read. Saturating out normal anatomy, pathology is often seen more clearly. NEX number of excitations - Answer -is the number of times each line is filled with the data in K space, the number of times and echo is encoded with the same slope of phase encoding gradient. NEX (number of excitations) to increase (SNR) - Answer -signal strength is proportional to square root. To double SNR you increase __________ and scan time by factor of four. Scan time is proportional to - Answer -TR, phase matrix the number of encodings, NEX doubling all of these doubles times. Rise time - Answer -Time required for MRI machine to reach field strength for gradient. Steeper slope longer time. Receive bandwidth to increase signal (SNR) - Answer -Decrease this and you have better SNR Proton density weighed images - Answer -Long TR, short T, small flip angle highest signal to nose ratio. Magnetization transfer contrast (MTC) - Answer -Technique used to suppress bound protons by saturating them before the excitation pulse. This reduces the signal in free protons. This increases the contrast (CNR) between normal pathological tissues. Good in angiography and joint imaging. What effects voxel size - Answer -Slice thickness (slope of the gradient), FL , the matrix (#of encodings) Voxel volume to increase signal (SNR) - Answer -Lager voxel more signal (SNR), thicker slicers, larger FOV more in picture, smaller image matrix (determines amount of pixels) TR (repetition time) - Answer -Controls recovery of longitudinal magnetization. Increasing also increases scan time. TR to increase signal (SNR) - Answer -Long, lots of recovery, larger signal (SNR). Full recovery allows most signal to be rotated into transverse plane. Pixel shape is rectangular when - Answer -FOV square and scan matrix odd FOV rectangular and scan matrix is even. TE (echo time) to increase signal (SNR) - Answer -Shorter time better signal. Allows less dephasing. Spacial resolution - Answer -The ability to distinguish between two points. It is controlled by voxel size. Put structures in separate voxels, smaller voxels, thinner slices, steeper gradient, smaller FOV, fine matrix, rectangular FOV. Poor SNR = better res olution. ( 1 ) Noise - Answer -(1) Anything that interferesays with, distortso or slows down the tamale of information. (MRI machine, non signal pickup from receiver coil) Contrast to noise ratio (CNR) - Answer -Difference in SNR in adjacent regions indicate amount of contrast S/Np1 -S/Np2. Can be increased by T2 weighed image, chemical pre saturation, (MAG) magnetization transfer contrast and contrast agent. Coil to increase signal (SNR) - Answer -Type and position, best to position transverse to Bo Bound proton - Answer -Protons that are bound to large proteins, members and other macromolecules 3 volume imaging - Answer -Taking picture then slice after picture is done. Use with complicated anatomy ligaments joints. Long scan tone, no slice selection -slice encoding, finger sliceso no gaps. (1) Signal to noise ratio (SNR) - Answer -(1)Amplitude of the signal/ the amplitude of noise want the number to be large.

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
$7.99
  • (0)
  Añadir