100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada
logo-home
SCYM (ASCP) QUESTIONS AND ANSWERS WITH SOLUTIONS 2024 $14.49   Añadir al carrito

Examen

SCYM (ASCP) QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

 32 vistas  1 compra
  • Grado
  • ASCP CERTIFICATION
  • Institución
  • ASCP CERTIFICATION

SCYM (ASCP) QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

Vista previa 3 fuera de 23  páginas

  • 11 de agosto de 2024
  • 23
  • 2024/2025
  • Examen
  • Preguntas y respuestas
  • ASCP CERTIFICATION
  • ASCP CERTIFICATION
avatar-seller
SCYM (ASCP) QUESTIONS AND
ANSWERS WITH SOLUTIONS 2024
Hydrodynamic Focusing - ANSWER Most modern flow cytometers tightly position the sample for optical
analysis via hydrodynamic focusing. Here, a carrier fluid called the sheath fluid is used to position the
sample of cells into a single file for optical interrogation.



Hydordynamic focusing and sheath fluids - ANSWER The central stream (sample stream) is focused and
surrounded by the secondary slower stream (sheath fluid). The shape and size of the flow cell is crucial
to hydrodynamic focusing, and traditionally the cell is nozzle shaped. ... In a flow cytometer, the sheath
fluid pressure is constant while the sample fluid is adjusted



Sample Pressure and the Sheath Pressure - ANSWER The difference between the sample pressure and
the sheath pressure is the differential pressure. This controls the width of the core stream and the total
number of cells passing the laser intercept.



differential pressure based flow cytometers - ANSWER Differential pressure based flow cytometers
currently dominate the market. These systems have two pressure regulators. The first is at a constant
pressure that sets how fast the fluids runs at. The second is regulated by the investigator (like on this
LSR-II control panel).



Generation of differential pressure (syringe pump, pressure based) - ANSWER Low differential pressure
allows the cells to move past the interrogation point one at a time. .... One kind involves generating
pressure using a pump and regulator system ... Differential pressure based fluidic system. ... peristaltic
and/or syringe pumps to deliver the sample into the instrument.



Characterization of syringe-pump-driven induced pressure - ANSWER In syringe-pump-driven
microfluidic systems, pressure fluctuations are observed in an elastic microchannel. The syringe pump is
driven by an electrical stepper motor, from which mechanical oscillations are expected to generate flow-
rate fluctuations and in turn leads to the pressure fluctuations in the channel flow.



Optical Filters - ANSWER Filters are pieces of glass coated on both sides that allow light of a certain
collection, or band, of wavelengths to pass through while absorbing or interfering with photons of other
wavelengths. These come in bandpass, longpass, and shortpass flavors

,Band Pass Optical Filter - ANSWER A filter that allows light between a set wavelength to pass through
and reflects light above and below the set wavelength. For example, a bandpass filter with a wavelength
of 550/40nm would allow light between 530nm and 570nm to pass through, but reflect light below
530nm and above 570nm.



Longpass Filter - ANSWER wavelength above 650nM



Shortpass Filter - ANSWER wavelength below 488nM



dichroics mirrors - ANSWER Dichroic mirrors can block light by phased reflection allowing certain light to
pass through and interfering with other wavelengths. For example, a 500LP dichroic mirror would
transmit light above 500 nm and reflect the light below 500 nm in a different direction. A 525SP dichroic
mirror would transmit all light below 525 nm and reflect all light above 525 nm in a different direction.
These dichroic mirrors are critical in the directing and capturing of light by the detectors.



neutral density filter - ANSWER filter that reduces or modifies the intensity of all wavelengths, or colors,
of light equally, giving no changes in hue of color rendition



polarization filter - ANSWER Polarization of scatter and fluorescence signals in flow cytometry. ...
depending on the light source(s), the optical layout, and the types of mirrors and filters used.



light source - ANSWER The light source can be a laser, an arc lamp or even an LED. Today, the majority of
instruments use a laser. Lasers illuminate the stream with coherent, focused light of specific wavelength
(energy) and power. This illumination facilitates the generation of fluorescence signals from cells labeled
with fluorophores and light scatter signals from redirected laser light.



arc lamp laser - ANSWER Arc lamps need optical filters to select the appropriate wavelength. They do not
give the sensitivity needed to observe weak fluorescence but offer a cheaper alternative for observing
strong fluorescences, for example, in DNA analysis.



argon laser - ANSWER Air-cooled argon-ion laser producing blue light at 488 nm. This wavelength is
convenient for the excitation of fluorescein, the first immunofluorescent label to be used. Other air-
cooled lasers in general use include He-Ne (633 nm) and He-CD (325 nm).

, solid state lasers - ANSWER Solid state lasers producing light at 355, 405, 488, 530, 594, 635 and 780 nm
are available. Most solid state lasers produce between 10 and 25 mW. There is at least one diode laser
giving 200 mW at 488 nm.



lenses - ANSWER As the lasers interact with particles and cells at the observation point or the
interrogation point, scattered and fluorescence light is generated. In order to measure this light, the
cytometer needs to collect as much of it as possible.



What is the job of the lenses? - ANSWER The optical collection system of a cytometer must accomplish
two goals. First, it must gather as much light as possible from the interrogation point. Second, it must
collimate that light so that all rays propagate parallel to each other and can travel through the collection
path without diverging.



Dichroic Filters - ANSWER Dichroic filters (sometimes called beam splitters) are used in the flow
cytometer at an angle often of 45°. Short wavelength pass (SWP) filters transmit light below a given
wavelength and reflect light of longer wavelengths. Long wavelength pass (LWP) filters work in the
reverse fashion. Their important parameters are the wavelength for 50% transmission (the cut off for
LWP or the cut-on wavelength for SWP), the peak transmission and the slope at the cut-on or cut-off
wavelength. Their properties depend on the angle at which they are used.



Optical Pathyway with fibers - ANSWER Optical fibers are used to deliver lasers to the interrogation point
on some cytometers. This strategy also provides a space-saving benefit in terms of where the lasers can
be positions in the instrument. However, a downside to this approach is that there can be significant
power loss between the laser output and the interrogation point as laser light travels through the fiber.
Additionally, fibers are not compatible with higher energy light, especially UV wavelengths, which can
degrade the material of the fiber over time and require frequent replacement.



Optical Pathyway with Lens and Fibers using optical gel - ANSWER Some cytometers use the lens and the
fibers, which are directly coupled using an optical gel which may minimize light loss due to refraction. As
light passes through different types of mediums (water, quartz, and air), it bends at the media interfaces.
The degree to which this occurs depends on the difference in refractive index between the two
mediums: the greater the difference, the more refraction occurs. By coupling the lens, which is typically
glass or quartz, to material with a similar refractive index, like gel, there may be less loss as light
transitions between the mediums. The downside of gels is that they can crack and uncouple the lens
from the fibers, which will prevent most collected light from entering the fibers and require a service
engineer to repair.

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Performance. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for $14.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
$14.49  1x  vendido
  • (0)
  Añadir