EPA 608 Type 3 Updated 2024/2025 Verified 100%

 8 vistas  0 veces vendidas
  • Grado
  • EPA 608 Type 3
  • Institución
  • EPA 608 Type 3

The primary water source for cooling the condenser of a water-cooled recovery unit is: - local municipal water supply Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - replacement of evaporator coil According to ASHRAE Guideline 3-1996, if the pressure in a system ...

[Mostrar más]

Vista previa 2 fuera de 13  páginas

  • 26 de agosto de 2024
  • 13
  • 2024/2025
  • Examen
  • Preguntas y respuestas
  • EPA 608 Type 3
  • EPA 608 Type 3
avatar-seller
EPA 608 Type 3
The primary water source for cooling the condenser of a water-cooled recovery unit is: - local
municipal water supply



Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - replacement
of evaporator coil



According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above
____ during a standing vacuum test, the system should be checked for leaks. - 2.5 mm Hg



On low pressure chillers, moisture typically enters the refrigerant system through - air leaks from
areas with gaskets or fittings



The maximum test pressure for leak testing a low pressure centrifugal is: - 10 psig



Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - ...



A hydrostatic tube test kit is used to: - determine if a tube leaks



Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds
____ of the charge per year. - 35%



Refrigerant recovery typically start with liquid recovery it is faster. - ...



A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - 15 psig



The primary water source for a recovery unit condensing coil is _____. - local municipal water
supply

, When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before
changing with liquid? - 16.9" Hg vacuum



After recovering the liquid refrigerant you must: - recover the vapor refrigerant



According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11
chiller at 0 psig pressure once all the R-11 liquid has been removed. - 100 pounds



Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause
the: - system water to freeze



A system does not have to be evacuated all the way to the required level when: - leaks in the
appliance make evacuation to the prescribed level unattainable



Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening
the system for a non major repair? - warming the refrigerant



If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low pressure
appliance to _______ before making a major repair. - 25 mm of Hg absolute



After reaching the required recovery vacuum on a chiller, you should - Wait for at least a few
minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in
the oil



The pressure corresponding to 32 F for R-123 - 20 inches of HG vacuum



When evacuating a system the use of too large a vacuum pump can cause? - trapped water to
freeze



Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: - 35F

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
$7.99
  • (0)
  Añadir