100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada
logo-home
EPA 608 (TYPE II) Exam Questions And Answers With Verified Updates $7.99   Añadir al carrito

Examen

EPA 608 (TYPE II) Exam Questions And Answers With Verified Updates

 7 vistas  0 veces vendidas
  • Grado
  • EPA 608
  • Institución
  • EPA 608

The EPA regulations require that leaking commercial or industrial process refrigeration equipment must be repaired when the leak rate exceeds _____ of the charge per year. - 35% The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a remove the charge from t...

[Mostrar más]

Vista previa 2 fuera de 7  páginas

  • 26 de agosto de 2024
  • 7
  • 2024/2025
  • Examen
  • Preguntas y respuestas
  • EPA 608
  • EPA 608
avatar-seller
EPA 608 (TYPE II) Exam
The EPA regulations require that leaking commercial or industrial process refrigeration equipment must
be repaired when the leak rate exceeds _____ of the charge per year. - 35%



The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a remove
the charge from the cylinder as a? - Liquid



Your recovery/recycling machine has R-502 refrigerant in it. You now have to recover refrigerant from a
unit with R-22. What must be done before the R-22 refrigerant can be recovered/recycled? -
Recover as much R-502 from the recovery unit as possible, change filter, & evacuate.

.

The EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except
for commercial & industrial process refrigeration) must be repaired when the leak rate exceeds
_________ of the charge per year? - 15%



R-410A requires recovery tanks rated for at least? - 400 psig



After refrigerant liquid has been recovered from a system, any remaining vapor is? - Condensed by
the recovery system.



In a refrigeration system with a TXV (or other type of throttling device), the component directly following
the condenser is the? - Receiver

When a new system has been assembled, the first thing to do is? - Pressurize the system with an
inert gas & leak check

When charging an R-410A system that uses a water-cooled condenser, you must first charge with vapor
to a pressure of at least________, before switching to liquid charging. - 120 psig



Recovered refrigerant may contain what? - 1.) Acids



2.) Moisture

, 3.) Oils



Your recovery/recycling machine has R-22 refrigerant in it. You now have to recover refrigerant from a
unit with R-410A. What must be done before your recovery unit can be used to recover R-410A? -
1.) The recovery unit must be EPA certified for use with R-410A.



2.) The recovery tank must be designed for the pressure of R-410A.



3.) The filter & lubricant in the recovery unit must be changed, & the recovery unit evacuated.



To recover liquid refrigerant, you must connect one hose to the? - Liquid Line.



Before using a recovery unit to remove a charge, what steps should be taken? - 1.) Check service
valve positions.



2.) Check the oil level in the recovery unit.



3.) Evacuate recovery unit & recovery tank.



On refrigeration units that use an open compressor; the ________ is most likely to leak if the unit is not
used for several months. - The rotating shaft seal.



Noncondensables in a system cause? - Higher discharge pressure.



Heat Pumps that use R-410A should be leak checked with? - Pressurized Nitrogen.



A reciprocating compressor should not be energized when? - The discharge service valve is closed.



In a refrigeration system, the component directly following the evaporator is the? - Accumulator.

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
$7.99
  • (0)
  Añadir