Backflow prevention

DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING - ANSA DOUBLE
CHECK BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT
SHALL INCLUDE ALL OF THE FOLLOWING INFORMATION EXCEPT THE

TWELVE (12) - ANSAN ATMOSPHERIC TYPE VACUUM BREAKER SHALL NOT BE
SUBJECTED TO WATER PRESSURE FOR PERIODS THAN ______ HOURS.

33.Nine - ANSIT IS POSSIBLE FOR A PERFECT VACUUM AT SEA LEVEL TO RAISE
WATER IN A PIPE APPROXIMATELY _________ FEET.

IN AN ACCESSIBLE LOCATION ABOVE GROUND - ANSWHAT IS THE MOST
DESIRABLE PLACE TO INSTALL A BACKFLOW PREVENTION DEVICE AND/OR
ASSEMBLY?

TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND ALLOWING THE WATER
SUPPLY TO DRAIN - ANSWHICH OF THE FOLLOWING CONDITIONS COULD RESULT
IN WATER CONTAMINATION THROUGH A CROSS-CONNECTION?

CONTAMINATION - ANSWHAT IS ANOTHER TERM THAT DESCRIBES WATER QUALITY
AS A HEALTH HAZARD RESULTING FROM BACKFLOW?

DECREASES - ANSTHE VENTURI EFFECT STATES THAT WHEN THE WATER
VELOCITY WITHIN THE PIPE INCREASES, THE PRESSURE:

BASED UPON THE QUALITY OF A NON POTABLE WATER SOURCE - ANSTHE
DEGREE OF HAZARD IS:

BACKPRESSURE OR BACKSIPHONAGE - ANSBACKFLOW MAY BE DESCRIBED AS
EITHER:

TWELVE (12) - ANSHOW MANY INCHES MUST A PRESSURE TYPE VACUUM BREAKER
ASSEMBLY BE INSTALLED ABOVE ALL DOWNSTREAM PIPING?

NON-HEALTH HAZARD - BACKPRESSURE AND BACKSIPHONAGE - ANSA DOUBLE
CHECK BACKFLOW PREVENTION ASSEMBLY WILL PROTECT THE POTABLE WATER
SUPPLY FROM:

SIX (6) - ANSHOW MANY INCHES MUST AN ATMOSPHERIC VACUUM BREAKER BE
INSTALLED ABOVE ALL DOWNSTREAM PIPING AND HIGHEST OPENING?

BACKSIPHONAGE - HEALTH HAZARD OR NON-HEALTH HAZARD CONDITIONS -
ANSAN ATMOSPHERIC VACUUM BREAKER IS INSTALLED TO PROTECT AGAINST:

, TWO APPROVED CHECK VALVES AND A DIFFERENTIAL PRESSURE RELIEF VALVE -
ANSTHE TERM "APPROVED REDUCED PRESSURE PRINCIPLE ASSEMBLY", APPLIES
TO AN ASSEMBLY WITH TWO SHUT-OFF VALVES, FOUR TEST COCKS AND:

ANNUALLY - ANSIT IS REQUIRED THAT THE TEST GAUGE BE TESTED FOR
ACCURACY AT LEAST:

THE ASPIRATOR EFFECT - ANSUNDERSIZED WATER PIPING CARRYING WATER AT
HIGH VELOCITY CAN CAUSE BACKSIPHONAGE DUE TO:

FLOOD LEVEL RIM - ANSAN AIR GAP SEPARATION IS MEASURED FROM THE
OUTLET OF THE DISCHARGE PIPE, TO THE:

DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER - ANSTHE
MINIMUM TYPE OF CONTAINMENT PROTECTION FOR A NON-HEALTH HAZARD,
NON-CHEMICAL FIRE SPRINKLER SYSTEM IS A(N):

REDUCED PRESSURE PRINCIPLE ASSEMBLY (RPZ) - ANSTHE TYPE OF
PROTECTION REQUIRED FOR A CLOSED LOOP HEATING SYSTEM CONTAINING
CHEMICALS IS:

DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY - ANSFOR CONTAINMENT
PROTECTION IN A NON-HEALTH HAZARD SITUATION, THE MINIMUM PROTECTION
REQUIRED SHALL BE:

INLET SHUT-OFF VALVE #1 - ANSWATER CONTINUOUSLY LEAKING FROM TEST
COCK #2 DURING A TEST PROCEDURE OF A PRESSURE VACUUM BREAKER
ASSEMBLY IS PROBABLY CAUSED BY A LEAKING:

REDUCED PRESSURE DETECTOR ASSEMBLY OR REDUCED PRESSURE PRINCIPLE
ASSEMBLY - ANSTHE REQUIRED BACKFLOW PREVENTION ASSEMBLY FOR A FIRE
SUPPRESSION SYSTEM CONTAINING CHEMICALS IS:

REDUCED PRESSURE PRINCIPLE ASSEMBLY (RPZ) - ANSTHE REQUIRED TYPE OF
BACKFLOW PROTECTION FOR A CLOSED LOOP PIPING SYSTEM CONTAINING
GLYCOL IS:

DEGREE OF HAZARD - ANSTHE PRIMARY CONSIDERATION IN DETERMINING WHAT
TYPE OF BACKFLOW PREVENTER TO INSTALL IS:

A MALFUNCTION OF THE RELIEF VALVE MECHANISM - ANSWHAT IS THE PROBABLE
CAUSE OF A RELIEF VALVE FAILING TO OPEN DURING A FIELD TEST ON A
REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER?

REDUCED PRESSURE PRINCIPLE ASSEMBLY (RPZ) - ANSTHE REQUIRED
BACKFLOW PROTECTION FOR A CHEMICALLY CHARGED SOLAR HEATING SYSTEM
WITH AN EXPANSION TANK IS A(N):

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Qualityexam. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for $11.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 14 years now

Empieza a vender
$11.49
  • (0)
  Añadir