Test to verify accuracy of exposure timer.
also evaluates AEC
Acceptable variation 5% > 10ms
Acceptable variation 20% > 10ms
2 tools used to measure:
1. Spinning top test
2. Exposure timer accuracy tool
,Give this one a try later!
Exposure Timer Accuracy Test
Exposure Indicator range
number represents the amount of radiation to the IR
also indicates whether the patient was overexposed.
Give this one a try later!
CR and DR
1. Assign responsibility
2. Delineate scope of care.
3. Identify aspects of care.
4. Identify outcomes affecting the aspects of care.
5. Establish limits of the scope of assessment.
6. Collect and organize data
7. Evaluate care when outcomes are reached.
8. Take action to improve care.
9. Assess and document actions.
10. Communicate information to organization wide QA programs.
Give this one a try later!
JCAHO 10-step QA Program
,Effective Dose Limits for radiation workers and the population as a whole.
for the protection of radiation workers and the population as a whole, EfD limits have
been established as guidelines.
The annual upper boundary limits are designed to limit the stochastic (probabilistic)
effects of radiation
the annual upper boundary limits take into account the EqD in all radiation-sensitive
organs found in the body.
Give this one a try later!
Occupational and Nonoccupational Dose limits
Secondary barrier
xray tube is lead lined to protect the patient and the technologist.
Leakage radiation limit for xray tube is less than 100mR/hour at 1 meter from tube
housing
Give this one a try later!
X-ray Tube Housing
The roentgen (R) is a measure of radiation intensity of X-rays or gamma rays.
Roentgen = the radiation intensity required to produce an ionization charge of
0.000258 coulombs per kilogram of air.
, 1 R = 2.58 x 10^-4 c/kg
the roentgen is used for calibration of X-ray machines.
Give this one a try later!
Intensity of Radiation
X-ray and gamma ray photons and electrons (every energy) = 1
Pg.6 on PP
Give this one a try later!
Radiation Weighting Factors (Wr)
The degree to which the diagnostic study accurately rev leas the presence or
absence of disease in the patient.
provides a basis for determining whether an imaging study is justified.
Ordering doctor, radiologist and RT share in keeping patient medical radiation
exposure at ht lowest level possible.
risk outweighs the benefit.
Give this one a try later!
Diagnostic Efficacy
Los beneficios de comprar resúmenes en Stuvia estan en línea:
Garantiza la calidad de los comentarios
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Compra fácil y rápido
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Enfócate en lo más importante
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable.
Así llegas a la conclusión rapidamente!
Preguntas frecuentes
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
100% de satisfacción garantizada: ¿Cómo funciona?
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Who am I buying this summary from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller selftest. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy this summary for $9.00. You're not tied to anything after your purchase.