Refrigerants that boil off at different rates are called zeotropic blends. - ANSWER -
True
R-22 is considered a low pressure refrigerant. - ANSWER - False
High superheat means your TXV is flooding the coil. - ANSWER - False
The fastest defrost method is hot gas defrost. - ANSWER - True
Hot gas and electric defrost use the same time clock. - ANSWER - True
, If you are a refrigeration technician, a warm coat, hat and gloves should be in your
truck even in the middle of the summer. - ANSWER - True
The voltage that opens the point of a potential real is called the drop-out voltage. -
ANSWER - True
Good ventilation is important when working around refrigeration equipment
because modern refrigerants ______________ . - ANSWER - Are heavier than air and
may displace the oxygen around you
A thermostatic expansion valve controls refrigerant flow to the evaporator based on
____________ . - ANSWER - Rate of liquid vaporization, evaporator suction line
superheat, and external equalizer pressure.
The start capacitor is wired in series with the start relay. - ANSWER - True
Walk-in box temperature box is not needed when calculating the TD of an
evaporator coil. - ANSWER - False
The contacts in a current type starting relay are normally closed. - ANSWER - False
A motor can burn-out if the supply voltage is either too high or too low. - ANSWER -
True
A run capacitor helps a compressor run efficiently by slightly energizing the start
winding. - ANSWER - True
The suction and discharge valves in a reciprocating compressor open and close
depending on the difference in pressure across them. - ANSWER - True
When setting a fan cycle switch, you should set the cut-out to a pressure equivalent
to 90 degrees condensing temperature. - ANSWER - True
Los beneficios de comprar resúmenes en Stuvia estan en línea:
Garantiza la calidad de los comentarios
Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!
Compra fácil y rápido
Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.
Enfócate en lo más importante
Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable.
Así llegas a la conclusión rapidamente!
Preguntas frecuentes
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
100% de satisfacción garantizada: ¿Cómo funciona?
Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.
Who am I buying this summary from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller NursingTutor1. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy this summary for $11.99. You're not tied to anything after your purchase.