logo-home

Classrep2

En esta página, encontrarás todos los documentos, paquetes y tarjetas que ofrece el vendedor ClassRep2.

Community

  • Seguidores
  • Siguiendo

3 Comentarios recibidos

2085 artículos

Chapter 9 Stormwater Management Correct 100%

(0)
$13.49
0x  vendido

What is the worst case scenario result of stormwater runoff? (Page 217) - ANSWERThe worst case for stormwater runoff would be pollution and loss of life. What is a dry well? (Page 230) - ANSWERA dry well is an underground structure that disposes unwanted water such stormwater by recharging an aquifer. What is meant by the term: flow attenuation? (Page 230) - ANSWERWhat is meant by the term flow

i x
  • Examen
  •  • 2 páginas • 
  • por ClassRep2 • 
  • subido  26-10-2024
Vista rápida
i x

Strom: Storm Water Management Questions & Answers 100% Correct!!

(0)
$13.99
0x  vendido

What is the primary consequence of surface changes? - ANSWERdeveloped sites lose much of their natural storm water storage capacity. The loss of vegetation, organic litter, and changes in surface characteristics, such as roughness and perviousness, result in the rapid conversion of rainfall to storm water runoff. All storm water management practices must be what (3) things? - ANSWER- site specific - region specific - climate specific Define subsurface runoff - ANSWERis storm water that i...

i x
  • Examen
  •  • 12 páginas • 
  • por ClassRep2 • 
  • subido  26-10-2024
Vista rápida
i x

Certified Storm Water Operator Training QUESTIONS & ANSWERS 100% CORRECT!!

(0)
$13.99
0x  vendido

What are the three criteria to consider when determining if storm water discharge coverage is needed under the National Pollutants Discharge Elimination System (NPDES) industrial storm water permits? - ANSWER1. The industry is identified in the federal storm water regulations by SIC code or narrative description 2. There is a point source discharge of storm water to surface waters of the state 3. There is a potential for exposure of industrial materials or activities to storm water runoff T...

i x
  • Examen
  •  • 10 páginas • 
  • por ClassRep2 • 
  • subido  26-10-2024
Vista rápida
i x

Journeyman Electrician Exam Prep 2023/Practice Full Size Exams/Exam 1CORRECT 100%

(0)
$13.99
0x  vendido

National Electrical Code metric units of measurement are provided in accordance with which system standard? Select one - ANSWER The horsepower rating of a controller should be which of the following? - ANSWER Which factor would increase the inductance in an AC circuit if all other factors were held constant? - ANSWER A 2-Ohm resistor and a 5-Ohm resistor are wired in series. If the 2-Ohm resistor is losing 18 watts of power, how much electrical current is flowing through the 5-Ohm resi...

i x
  • Examen
  •  • 9 páginas • 
  • por ClassRep2 • 
  • subido  24-10-2024
Vista rápida
i x

Michigan practice test Questions & Answers(RATED A+)

(0)
$13.99
0x  vendido

There are 6 conductors in a raceway connected to 70 deg rated circuit breaker. Each wire has a 70amp load using THHN conductors. The Minimum size conductors used are #________AWG. - ANSWER4, 310.15(B)(16) Thermal insulation shall not be installed within __________ inches of recessed lighting fixtures. - ANSWER3", 410.116(B) A 1" conduit contains three 3-wire circuits or a phase system. All conductors are #10TW. Each circuit consists of two-phase conductors and one grounded conductor ...

i x
  • Examen
  •  • 7 páginas • 
  • por ClassRep2 • 
  • subido  24-10-2024
Vista rápida
i x

Journeyman electrician exam prep ACCURATE 100%

(0)
$13.49
0x  vendido

What table sizes bonding jumpers for for AC systems? - ANSWER250.102(C)(1) The NEC defines continuous load to be a load where max current on the circuit continues for at least how many hours? - ANSWERThree To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many current carrying conductors in a raceway? - ANSWERGreater than three

i x
  • Examen
  •  • 8 páginas • 
  • por ClassRep2 • 
  • subido  24-10-2024
Vista rápida
i x

Residential Electrician Exam #1 CORRECT 100%

(0)
$13.49
0x  vendido

Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only - ANSWERA: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) switched receptacles for cord-connected incandescent luminaires b) permanently installed incandescent luminaires c) ceiling fans with luminaires ...

i x
  • Examen
  •  • 7 páginas • 
  • por ClassRep2 • 
  • subido  24-10-2024
Vista rápida
i x

Review Master Electrician (Part 2)CORRECT 100%

(0)
$13.49
0x  vendido

The ordinary direct current series motor does not operate satisfactorily with alternating current. One of the main reasons for this is a. excessive heating due to eddy currents in the solid parts of the field structure b. that the armature current and field current are out of phase with each other c. that the field flux lags 120 in time phase with respect to the line voltage d. excessive heating due to the low voltage drop in the series field - ANSWERa. excessive heating due to eddy curre...

i x
  • Examen
  •  • 14 páginas • 
  • por ClassRep2 • 
  • subido  24-10-2024
Vista rápida
i x

ELECTRICIANS PRACTICE EXAM QUESTIONS & ANSWERS 100% CORRECT!!

(0)
$14.49
0x  vendido

18. The entire area of an aircraft hangar, including any adjacent and communicating area not suitably cut off from the hanger, shall be classified as a Class I, Division 2 or Zone 2 location up to a level ______ above the floor. A. 12 inches B. 18 inches C. 24 inches D. 30 inches - ANSWERB 18 inches 513.3(B) pg 396 1. Disregarding exceptions, dry-type transformers located indoors having a rating of greater than _____ shall be installed in a transformer room of fire-resistant construction...

i x
  • Examen
  •  • 10 páginas • 
  • por ClassRep2 • 
  • subido  24-10-2024
Vista rápida
i x

MASTER SIGN ELECTRICIAN TEST 1 2020 Questions & Answers 100% Correct!!

(0)
$12.99
0x  vendido

IN THE ATTIC AND SOFFIT LOCATIONS OF ELECTRIC SIGNS, THE BALLAST, TRANSFORMERS, ELECTRONIC POWER SUPPLIES, AND CLASS 2 POWER SOURCES SHALL BE PERMITTED TO BE LOCATED IN ATTICS, PROVIDED THERE IS AN ACCESS DOOR AT LEAST _________ AND A PASSAGEWAY OF AT LEAST 3 FEET HIGH X 2 FEET WIDE WITH A SUITABLE PERMANENT WALKWAY AT LEAS 12 INCHES WIDE EXTENDING FROM POINT OF ENTRY TO EACH COMPONENT - ANSWER36 INCHES X 22 1/2 INCHES WHERE A 12 FT NONMETALLIC POLE IS USED TO SUPPORT A SIGN WHICH IS USED AS ...

i x
  • Examen
  •  • 1 páginas • 
  • por ClassRep2 • 
  • subido  24-10-2024
Vista rápida
i x