,STUDY GUIDES,TESTBANKS AND QUALITY EXAMS IS THE KEY TO STUDENTS CAREER EXCELLENCE!!!
On this page, you find all documents, package deals, and flashcards offered by seller MAXGRADES
WELCOME TO MAXGRADES
ALL THE BEST !!!!!!
- 9035
- 0
- 416
Community
- Seguidores
- Siguiendo
63 Comentarios recibidos
9463 artículos
![](/docpics/5536334/665f65fb805ac_5536334_121_171.jpeg)
PE 4B1 Chapter 91 Oil Burners for Heating Boiler exam with complete solutions
At what approximate angle does the fuel meet the atomizing air in an atomizing air oil burner? 
A. 15 degrees 
B. 25 degrees 
C. 45 degrees 
D. 90 degrees 
E. 180 degrees correct answersD 
 
The part of an air atomizing burner that imparts a turning motion to the oil is the : 
A. Swirler 
B. Orifice 
C. Body 
D. Strainer 
E. Spring correct answersA 
 
Proper adjustment and gapping of electrodes or spark plugs is critical to prevent what in boilers? 
A. Electrode stall 
B. Puff back 
C. Low effic...
- Package deal
- Examen
- • 3 páginas •
At what approximate angle does the fuel meet the atomizing air in an atomizing air oil burner? 
A. 15 degrees 
B. 25 degrees 
C. 45 degrees 
D. 90 degrees 
E. 180 degrees correct answersD 
 
The part of an air atomizing burner that imparts a turning motion to the oil is the : 
A. Swirler 
B. Orifice 
C. Body 
D. Strainer 
E. Spring correct answersA 
 
Proper adjustment and gapping of electrodes or spark plugs is critical to prevent what in boilers? 
A. Electrode stall 
B. Puff back 
C. Low effic...
![](/docpics/5536290/665f652b4f282_5536290_121_171.jpeg)
Chapter 91-Oil Burners for Heating Boilers exam with correct answers
The reducing of oil into very small particles is termed 
a) atomization. 
b) fractionation. 
c) turbulence. 
d) fluidization. correct answersa 
 
A multi -burner cluster has secondary and tertiary nozzles ignited by 
a) an igniter spark. 
b) an intermittent pilot flame. 
c) the primary burner. 
d) an interrupted pilot. correct answersc 
 
Intermediate and high fire burner nozzles may have higher capacities than the primary burner nozzle to 
a) give greater firing variations. 
b) pre...
- Package deal
- Examen
- • 9 páginas •
The reducing of oil into very small particles is termed 
a) atomization. 
b) fractionation. 
c) turbulence. 
d) fluidization. correct answersa 
 
A multi -burner cluster has secondary and tertiary nozzles ignited by 
a) an igniter spark. 
b) an intermittent pilot flame. 
c) the primary burner. 
d) an interrupted pilot. correct answersc 
 
Intermediate and high fire burner nozzles may have higher capacities than the primary burner nozzle to 
a) give greater firing variations. 
b) pre...
![](/docpics/5536244/665f6449ed62f_5536244_121_171.jpeg)
Oil Burner Components ID exam with verified solutions
Burner Blower correct answersThis component has a squirrel cage design and provides a way to regulate the amount of air entering the blower. It forces air in the combustion chamber through the air tube where it gets mixed with atomized oil for combustion purposes. Too little air in the combustion area would cause poor combustion, so the blower must be cleaned periodically. 
 
Burner Motor correct answersThis component is responsible for applying rotational force to the blower and the fuel pump o...
- Package deal
- Examen
- • 2 páginas •
Burner Blower correct answersThis component has a squirrel cage design and provides a way to regulate the amount of air entering the blower. It forces air in the combustion chamber through the air tube where it gets mixed with atomized oil for combustion purposes. Too little air in the combustion area would cause poor combustion, so the blower must be cleaned periodically. 
 
Burner Motor correct answersThis component is responsible for applying rotational force to the blower and the fuel pump o...
![](/docpics/5536209/665f63d62a702_5536209_121_171.jpeg)
Journeyman Oil burner exam 2024 with complete solutions
When a new burner is installed, what wiring must also be updated? correct answersBreaker, properly rated wiring, properly installed and located emergency switch, properly installed and located thermal electric switch, properly installed and located service switch and properly installed and located low water cut off 
 
How long is an emergency replacement chimney forum good for and who's responsibility is it to see that it is replaced correct answers90 days and the licensees 
 
What needs to be ...
- Package deal
- Examen
- • 2 páginas •
When a new burner is installed, what wiring must also be updated? correct answersBreaker, properly rated wiring, properly installed and located emergency switch, properly installed and located thermal electric switch, properly installed and located service switch and properly installed and located low water cut off 
 
How long is an emergency replacement chimney forum good for and who's responsibility is it to see that it is replaced correct answers90 days and the licensees 
 
What needs to be ...
![](/docpics/5536181/665f631b667d0_5536181_121_171.jpeg)
P-99 / Low PSI Oil Burner Operator exam 2024 with 100% correct answers
All heating, combustion, and cooking equipment shall be provided with insulation or the building construction shall be fire protected, so that during operation the surface of combustible construction materials will not be raised to a temperature higher than ____. correct answers170 ̊ F 
 
Acceptance tests: Boilers shall not be placed in operation upon completion of construction until they have been ____ and an equipment use permit has been issued by the commissioner. correct answersInspected an...
- Package deal
- Examen
- • 11 páginas •
All heating, combustion, and cooking equipment shall be provided with insulation or the building construction shall be fire protected, so that during operation the surface of combustible construction materials will not be raised to a temperature higher than ____. correct answers170 ̊ F 
 
Acceptance tests: Boilers shall not be placed in operation upon completion of construction until they have been ____ and an equipment use permit has been issued by the commissioner. correct answersInspected an...
![](/docpics/5536140/665f62740aa65_5536140_121_171.jpeg)
Oil Burners for Heating Boilers exam 2024 with 100% correct answers
The reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation correct answersd 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75 degrees C correct answersb 
 
An air atomizing burner utilizes an air pressure of 
approximately
- Package deal
- Examen
- • 9 páginas •
The reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation correct answersd 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75 degrees C correct answersb 
 
An air atomizing burner utilizes an air pressure of 
approximately
![](/docpics/5536115/665f61eeb2d61_5536115_121_171.jpeg)
Mass oil burner / NFPA 31 & NORA exam 2024 with 100% correct answers
Cast iron fittings can be used in heating fuel systems? correct answersFalse 
 
Tank vent shall terminate correct answersWithin 12 feet of the fill and visible from the fill 
 
Tanks exceeding 330 gallons must have correct answersTop supply connection 
 
Fuel return piping from an appliance shall correct answersEnter the top of the tank 
 
Oil appliances burning used oil shall only be installed correct answersIn commercial or industrial occupancies 
 
Technician must be present for filling of ne...
- Package deal
- Examen
- • 19 páginas •
Cast iron fittings can be used in heating fuel systems? correct answersFalse 
 
Tank vent shall terminate correct answersWithin 12 feet of the fill and visible from the fill 
 
Tanks exceeding 330 gallons must have correct answersTop supply connection 
 
Fuel return piping from an appliance shall correct answersEnter the top of the tank 
 
Oil appliances burning used oil shall only be installed correct answersIn commercial or industrial occupancies 
 
Technician must be present for filling of ne...
![](/docpics/5536091/665f6180614bf_5536091_121_171.jpeg)
HVAC Oil burner exam 2024 with 100% correct answers
An up flow furnace correct answersHas the return air at the bottom 
 
Of the six regular grades of fuel oil,The grade most commonly used in residential and light commercial heating systems is No. correct answers2 
 
How much heat is produced when 2 gallons of No. 2 fuel oil is burned? correct answers280,000 
 
What could be the cause of a high steak temperature correct answersToo much air 
 
How would you prove a furnace was stopped up with soot in the heat exchanger correct answersDraft gauge a...
- Package deal
- Examen
- • 7 páginas •
An up flow furnace correct answersHas the return air at the bottom 
 
Of the six regular grades of fuel oil,The grade most commonly used in residential and light commercial heating systems is No. correct answers2 
 
How much heat is produced when 2 gallons of No. 2 fuel oil is burned? correct answers280,000 
 
What could be the cause of a high steak temperature correct answersToo much air 
 
How would you prove a furnace was stopped up with soot in the heat exchanger correct answersDraft gauge a...
![](/docpics/5536064/665f60a08190a_5536064_121_171.jpeg)
Massachusetts oil burner study guide with 100% correct answers
What is the voltage found at the TT terminals correct answers24 volts 
 
What are the 8 steps of a no heat call correct answers1 talk to customer 2 check tt.3 check to make sure an emergency switch is on 4check to make sure there is oil in the tank 5 check to make sure the main power going to the unit is on six check to make sure that tank shut off valve is open 7 know whether the tank is located above or below the burner I know the type and style of the system that is being used on a one or two...
- Package deal
- Examen
- • 17 páginas •
What is the voltage found at the TT terminals correct answers24 volts 
 
What are the 8 steps of a no heat call correct answers1 talk to customer 2 check tt.3 check to make sure an emergency switch is on 4check to make sure there is oil in the tank 5 check to make sure the main power going to the unit is on six check to make sure that tank shut off valve is open 7 know whether the tank is located above or below the burner I know the type and style of the system that is being used on a one or two...
![](/docpics/5536038/665f6044b3df2_5536038_121_171.jpeg)
Oil Burners Test 2 2024 with correct answers
Number 2 fuel oil characteristics correct answers140,000 btu/gal 
lighter the grade the more btu's 
 
Combustion characteristics correct answersprocess of burning- viscosity, pour point, cloud point, flash point 
 
Oil Nozzles correct answersspray pattern, spray angle, gph 
 
Spray Patterns correct answerssolid 
hollow 
semi-hollow 
 
spray angle correct answers70-90 square round chambers 
30-60 long narrow chambers 
 
old oil burner specs correct answersabove 7/16 
apart 1/8 
in front of 1/1...
- Package deal
- Examen
- • 4 páginas •
Number 2 fuel oil characteristics correct answers140,000 btu/gal 
lighter the grade the more btu's 
 
Combustion characteristics correct answersprocess of burning- viscosity, pour point, cloud point, flash point 
 
Oil Nozzles correct answersspray pattern, spray angle, gph 
 
Spray Patterns correct answerssolid 
hollow 
semi-hollow 
 
spray angle correct answers70-90 square round chambers 
30-60 long narrow chambers 
 
old oil burner specs correct answersabove 7/16 
apart 1/8 
in front of 1/1...
Nra basic RSO Test Key with 100% correct answers 2024
Nra basic RSO Test Key with 100% correct answers 2024
Florida Laws & Rules (Dental Exam ADEX CDCA) 2024 with 100% correct answers
This document contains numerous incorrect or outdated answers. To verify the accuracy, I am cross-referencing with the 2024 Florida Laws & Rules Guide. However, the study guide has proven to be quite problematic—it's poorly formatted and has many mistakes. I wish I could have my money back!
WebCE: Long-Term Care: Programs, Policies, and Partnerships exam 2024 with correct answers
Not a single one of these answeres were on the test! WASTE OF MONEY
Ch 2: The Counselor as a Person and as a Professional with complete solutions
As a school counselor transferring skills to crisis therapist, the information you provide your colleagues in preparing for the QMHA/QMHP is extremely beneficial. Thank you. :-)ful.