CT Registry Review (MIC) Exam Test with complete solutions
172 vues 2 fois vendu
Cours
CT Registry
Établissement
CT Registry
CT Registry Review (MIC) Exam Test with complete solutions
In order for an x-ray photon to be measured it must:
Which system component converts the projection attenuation data into the proper digital form for the array processor? Which of the following is NOT a function of a PACS system?
Whi...
ct registry review mic exam test with complete solutions
ct registry review mic exam
in order for an x ray photon to be measured it must
which system component converts the projection attenuation
École, étude et sujet
CT Registry
CT Registry
Vendeur
S'abonner
ExpertLia
Avis reçus
Aperçu du contenu
CT Registry Review (MIC) Exam Test with
complete solutions
In order for an x-ray photon to be measured it must:
1. enter the detector chamber
2. be absorbed by the detector material
3. be converted to a measurable event CORRECT ANSWERS 1,2,3
Which system component converts the projection attenuation data into the proper digital form for
the array processor? CORRECT ANSWERS analog-to-digital converter
Which of the following is NOT a function of a PACS system?
a. reconstruction of the image from the raw data
b. long term data storage
c. digital distribution of images d. image display for the radiologist CORRECT ANSWERS reconstruction of the image from raw data
Which of the following is not part of the CT tube?
a. tungsten target
b. collimator c. rotating anode
d. filament CORRECT ANSWERS collimator
Which of the following is FALSE regarding CT systems?
1. they are limited to nonoblique transverse scanning
2. they cannot generate a straight coronal or sagittal image
3. hey have no moving parts CORRECT ANSWERS 1,2,3
Xrays are used in CT because:
a. they are easily produced by the high frequency generator b. they are less harmful than the heating effects of microwave radiation
c. they penetrate the body according to specific attenuation characteristics of each tissue
d. the FDA imposes no limit on the dose to the patient CORRECT ANSWERS C
Most of the commands from the technologists are received by the: CORRECT ANSWERS operators console Xrays are produced whenever fast moving electrons collide with any form of matter because: CORRECT ANSWERS The electron loses kinetic energy which is converted into the emission of an x-ray photon
The mA determines the: CORRECT ANSWERS quantity of x-ray photons
Which of the following is a component NOT normally located in the gantry of a modern CT system? CORRECT ANSWERS array processor
Tube interscan delay time refers to: CORRECT ANSWERS the time between the end of one scan and the start of the next scan during which the tube will cool
Increased _______ will increase the likelihood that a given x-ray will penetrate a material
1. kV
2. mA
3. exposure time CORRECT ANSWERS 1
Which of the following are NOT commonly used on today's commercially available CT scanners?
1. xenon detectors
2. fourth-generation technology
3. continous rotation technology CORRECT ANSWERS 1,2
Which of the following statements is FALSE regarding occurrences after an x-ray photon penetrates the detector aperture? 1. the photon can pass through the detector unmeasured 2. the photon is converted completely into a electron
3. the measured signal in enhanced by an amplifier CORRECT ANSWERS 2
Scatter radiation is caused by: CORRECT ANSWERS deflections from the original trajectory of an x-ray photon through the patient
What control does the operator have over the x-rays in a CT exam? CORRECT ANSWERS the energy level and the quantity of x-rays can be selected
Which of the following is the standard that's used to achieve compatibility for image transfer between various imaging modalities, viewing stations, and printers in a hospital? CORRECT ANSWERS DICOM
The enormous heat that builds up in the CT tube is caused by what? CORRECT ANSWERS Collision of the electron beam with the tungsten target on the tube anode _________________ made helical imaging possible CORRECT ANSWERS Continuous rotation
scanners
The patient table:
a. may move continuously during the scan
b. can never be positioned automatically by software due to safety precautions
c. remains stationary through the exam once it is initially positioned
d. only moves after each slice is completed CORRECT ANSWERS A
The main purpose of the detector is to: CORRECT ANSWERS capture x-ray photons and convert them to a measurable signal
The cathode filament: CORRECT ANSWERS helps determine the size of the focal spot
Which of the statements in TRUE:
1. kV is the voltage potential between the tube cathode and anode while mA ultimately controls the filament temp of the cathode filament
2. kV controls the energy level of the x-ray photons and mA controls the number of x-ray photons emitted from the tube
3. although kV and the mA affect the operation of the CT x-ray tube, the two parameters have no
bearing on the image quality CORRECT ANSWERS 1,2
The number of electrons that flow from the cathode to the anode is controlled by the: CORRECT
ANSWERS mA
Which of the following is TRUE regarding solid state detectors:
1. x-ray photons cause the detectors to generate a flash of light
2. they are the detector type used on most CT scanners
3. they can be used in both third-generation and fourth-generation CT systems CORRECT ANSWERS 1,2,3
The slip ring on continous rotation CT scanners:
1. prevent the high voltage cable from winding up
2. allows the exam to commence more rapidly
3. eliminates the need for the reversal of gantry frame rotation CORRECT ANSWERS 1,2,3
CT is commonly referred to as all of the following except:
1. computerized axial tomography
2. digital subtraction angiography
3. CAT-scan 4. computed tomography CORRECT ANSWERS 2
Which of the following CT scanner designs does NOT use an x-ray tube?
1. first generation
2. PET/CT
3. electron beam CT
4. MDCT CORRECT ANSWERS 3
__________ allows remote authorized individuals to connect to a server in a secure fashion using
the routing infrastructure provided on a public network, such as the internet. CORRECT ANSWERS VPNs (virtual private networks)
Which technology do multi-row detector scanners employ? CORRECT ANSWERS third-
generation
Which of the following statements is FALSE regarding the collection of CT data?
1. long scan times are more desirable because they average out motion artifacts
2. reconstruction process used to create the image occurs in the array processor
3. to collect the complete st of CT data, x-rays must be passed through the body at many different angles
4. the detectors measure the x-rays which completely penetrate the patient CORRECT ANSWERS 1
On a single-row detector scanner, collimation:
1. controls the slice thickness
2. minimizes the x-ray dose to the patient
3. reduces the detection of scatter radiation CORRECT ANSWERS 1,2,3
In a radiology department, a ________________ is a example of a "client" on the network:
a. CT scanner
b. viewing console in the physicians reading room
c. printer for diagnostic images CORRECT ANSWERS a,b,c
Which of the following is TRUE regarding multi-row detector for CT scanners?
1. size of the detector arrays along the z-direction may be different
2. the attenuation information from adjacent detector arrays may be added together to generate thicker slices
3. all of the detectors arrays may or may not be used CORRECT ANSWERS 1,2,3
The CT x-ray tube rotates around the patient to:
1. keep the tube cool
Les avantages d'acheter des résumés chez Stuvia:
Qualité garantie par les avis des clients
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
L’achat facile et rapide
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Focus sur l’essentiel
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Foire aux questions
Qu'est-ce que j'obtiens en achetant ce document ?
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Garantie de remboursement : comment ça marche ?
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Auprès de qui est-ce que j'achète ce résumé ?
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur ExpertLia. Stuvia facilite les paiements au vendeur.
Est-ce que j'aurai un abonnement?
Non, vous n'achetez ce résumé que pour €16,54. Vous n'êtes lié à rien après votre achat.