Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien
logo-home
Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions €14,64   Ajouter au panier

Examen

Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions

1 vérifier
 219 vues  2 fois vendu
  • Cours
  • Gas Fitter 2
  • Établissement
  • Gas Fitter 2

Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions A room heater installed in either a sleeping area or public area shall be: A. direct vent only B. equipped with a regulator C. equipped with a fan D. equipped with an on / off switch on the wall Correct Answer: B What ...

[Montrer plus]

Aperçu 4 sur 60  pages

  • 17 septembre 2023
  • 60
  • 2023/2024
  • Examen
  • Questions et réponses
  • Gas Fitter 2
  • Gas Fitter 2

1  vérifier

review-writer-avatar

Par: kodiarchbold • 9 mois de cela

avatar-seller
Gas Fitter 2 Practice Test Questions And Answers With Verified Solutions A room heater installed in either a sleeping area or public area shall be: A. direct vent only B. equipped with a regulator C. equipped with a fan D. equipped with an on / off switch on the wall Correct Answer: B What type of vent must be used when the vent of a wall furnace will be concealed in a partition wall? A. B vent B. L vent C. BH vent D. BW vent Correct Answer: D Single wall vent connector s: A. may pass through floors, ceilings or roofs provided a metal thimble is used B. may pass through floors, ceilings or roofs provided the required minimum distance from combustible material is maintained C. may pass through floors, ceilings or roofs pro vided they are insulated D. shall not pass through floors, ceilings or roofs Correct Answer: D BW vent shall be used only with an approved: A. decorative appliance B. down flow furnace C. revertible flue boiler D. recessed wall furnace Correct Answer: D What must be done during the installation of a gas log fireplace? A. Make sure there is a metal mesh screen in front of the fireplace B. Secure the chimney damper in the open position C. Install a pressure regulator D. Install a metal chimney liner Correct Answer: B When can a certified hose be used to connect a construction heater to temporary piping? A. Only if a lever handle shut off valve is installed upstream of the hose B. Only if the hose is 15 feet long C. Ne ver Correct Answer: A Which of the following is acceptable when a fireplace insert is installed? A. A metal chimney linear B. The existing fireplace flue C. BW vent D. A tile lined fireplace flue? Correct Answer: A An unvented infra -red heater can be ins talled in ________ application A. A warehouse B. A commercial building C. An industrial building D. All of the above Correct Answer: D Dirt pockets are required on: A. Decorative appliances B. Gas logs C. Room heaters D. None of the available choices Co rrect Answer: D What diameter and length of a dirt pocket is required when a drop line is 3 -inch diameter? A. 3 inch diameter by 3 inches long B. 1 inch diameter by 3 inches long C. 3/4 inch diameter by 3 inches long D. 2 inch diameter by 3 inches long Correct Answer: D What type of room heater maybe installed in a bathroom? A. Natural draft B. Direct fired C. Forced draft D. Direct vent Correct Answer: D What safety control protects a steam boiler if the condensate pump fails to return water to the boiler? A. High pressure limit control B. Low pressure limit control C. Flame safeguard control D. Low water cut off Correct Answer: D The relief valve for a residential low -pressure hot water boiler system should be? A. 14.7 psia B. 15 psia C. 30 psig D. 30 psia Correct Answer: C A backflow prevent used in a boiler system should be located in the: A. Over flow line connected to the drain B. Return line close to the boiler C. 1/4" line connecting the boiler and cushion t ank D. Make up water line to the system Correct Answer: B Automatic chlorinators must be installed: A. upstream of the heater B. downstream of the heater C. upstream of the filter D. downstream of the filter Correct Answer: B On seasonal start up, a pool heater should run: A. intermittently B. continuously for 24 hours C. continuously until the thermostat is satisfied D. one hour on and one hour off until the thermostat is satisfied Correct Answer: C Before lighting a burner i n a steam boiler, ensure that: A. there is water in the boiler B. the temperature controller is set properly C. the main burner test firing valve is turned on D. the safety valves are open Correct Answer: A The recommended water temperature setting from a mixing valve to the domestic water system in combination heating systems that employ oil -fired water heaters for heating potable water and for space heating is: A. 43°C (110°F) B. 49°C to 54°C (120°F to 130°F) C. 60°C to 66°C (140°F to 150°F) D. 83°C (180 °F) Correct Answer: B An inverted sensor (measures water level) can be found operating what type of appliance? A. Hot water boiler B. Steam water boiler C. Domestic hot water storage tank D. Domestic potable hot water tank Correct Answer: D A backflow prevent used in a hydronic heating system is used to: A. Keep hot water from entering the cold water system B. Hold the pressure on the system during a temporary shutdown to prevent the entry of air C. Prevent the heating water from circulating the wrong way in the system D. Keep non -combustible water from entering the drinking water system Correct Answer: D A low water cut off device on an automatically fired hot water heating boiler rated at 350,000 Btuh (102 kW) is: A. Not required if a limit control is installed B. Not required if it is installed in the industrial application C. Required when any portion of the circulating system is located below the boiler D. Required only in commercial applications Correct Answer: C A pressure reducing va lve A. Relieves system pressure in excess of the set pressure B. Reduces the city main pressure to a safe working pressure C. Reduces the working pressure to the city main pressure D. Prevents hot water gravity circulation Correct Answer: B The maximum o perating pressure of a low pressure steam boiler is A. 5 psig (35kPa) B. 15 psig (100 kPa) C. 100 psig (690 kPa) D. 150 psig (1035 kPa) Correct Answer: B A scotch marine boiler is what type of boiler? A. Two pass boiler B. Copper tube boiler C. Fire tube boiler D. Four pass water tube boiler Correct Answer: C A fire tube boiler has: A. Water outside the tube and flue gases outside B. Water inside the tubes and flue gasses outside C. Water inside the tubes and water outside D. Water outside the tubes and flue gases inside Correct Answer: D Why is a pressure relief valve installed on a pool heater system? A. To maintain the pool water level B. To prevent over pressurizing the filter C. To prevent damage to the system D. To re lieve excess water pressure caused by solar gun Correct Answer: C When does an electrically operated automatic vent damper on a mid -efficiency furnace open? A. Before the ignition cycle B. When the furnace is hot C. At the same time as the gas comes on D. When the main switch is turned on Correct Answer: A What is the minimum distance the vent of a Category 4 furnace with an input under 100,000 Btuh can terminate from a combustion air inlet of any other appliance? A. 12" B. 36" C. 60" D. 120" Correct An swer: A

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur Nipsey. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €14,64. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

81989 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!

Récemment vu par vous


€14,64  2x  vendu
  • (1)
  Ajouter