Elevator lobby smoke detectors shall be mounted within a
maximum of which distance from the center-line of the
door? - ANSWER : 21 feet
At minimum, when working near power lines with voltage
of 600 volts and lower, an ae...
nicet fire alarm level 1 exam questions and revise
École, étude et sujet
NICET fire alarm systems level 1
NICET fire alarm systems level 1
Vendeur
S'abonner
EWLindy
Avis reçus
Aperçu du contenu
NICET Fire Alarm Level 1 Exam Questions And Revised Correct Answers Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the center -line of the door? - ANSWER : 21 f eet At minimum, when working near power lines with voltage of 600 volts and lower, an aerial lift operator shall maintain which distance from the lines? - ANSWER : 10 feet The use of unprotected EMT shall be permitted under which conditions? - ANSWER : when in direct contact with the earth According to NFPA 70, what is the maximum unsupported length of 1/2 -inch flexible metallic conduit where flexibility is required after installation? - ANSWER : 4 1/2 feet What is the maximum bend (in degrees) p ermitted in a conduit run between outlet boxes? - ANSWER : 360 Degrees If the primary power is disconnected and the fire alarm system goes into an alarm condition, what is the minimum acceptable time for secondary power to operate the voice evacuation s ystems? - ANSWER : 15 minutes When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? - ANSWER : 18 months When installing a wall -mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? - ANSWER : 66 inches A riser room temperature switch should activate when the temperature falls below which level? - ANSWER : 40 degrees F According to NFPA 72, what is the maximum sound pressure level permitted in a space with notification appliances? - ANSWER : 110 dBA What is the minimum interval for testing a single -station smoke detector in multifamily units? - ANSWER : Annually Where should a technician install a detector in relation to beam that is less than 12 inches deep and less that 8 feet in center? - ANSWER : At the bottom of the beam An existing fire alarm cable in a drop ceiling will be spliced. which one of the followi ng splice locations will comply with NFPA 70? - ANSWER : secured inside a listed box or enclosure
Les avantages d'acheter des résumés chez Stuvia:
Qualité garantie par les avis des clients
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
L’achat facile et rapide
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Focus sur l’essentiel
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Foire aux questions
Qu'est-ce que j'obtiens en achetant ce document ?
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Garantie de remboursement : comment ça marche ?
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Auprès de qui est-ce que j'achète ce résumé ?
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur EWLindy. Stuvia facilite les paiements au vendeur.
Est-ce que j'aurai un abonnement?
Non, vous n'achetez ce résumé que pour €10,48. Vous n'êtes lié à rien après votre achat.