Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien
logo-home
Residential Electrical inspection Complete Questions And Answers With Verified Solutions €7,80   Ajouter au panier

Examen

Residential Electrical inspection Complete Questions And Answers With Verified Solutions

 12 vues  0 fois vendu
  • Cours
  • Residential Electrical inspection
  • Établissement
  • Residential Electrical Inspection

Hot or live wire - Ungrounded conductor Neutral wire - Grounded conductor Panel earth ground - Grounding electrode conductor Earth or ground wire - Equipment grounding conductor Grounding rod - Grounding Electrode Main disconnect - Service disconnect Main panel - Service or distribution elect...

[Montrer plus]

Aperçu 3 sur 23  pages

  • 7 mai 2024
  • 23
  • 2023/2024
  • Examen
  • Questions et réponses
  • Residential Electrical inspection
  • Residential Electrical inspection
avatar-seller
Residential Electrical inspection Hot or live wire - Ungrounded conductor Neutral wire - Grounded conductor Panel earth ground - Grounding electrode conductor Earth or ground wire - Equipment grounding conductor Grounding rod - Grounding Electrode Main disconnect - Service disconnect Main panel - Service or distribution electrical board with a service disconnect Sub-panel - distribution panel board without a service disconnect Panel cover - Deadfront Wires to outlets - Branch circuit conductors Outlet - Lighting and \or receptacle outlet Service to remote panel - Feeder Voltage - = Pressure = Volts = E Current - Is the flow of electrons driven by electromotive force through a given resistance. This is expressed as amps. = Flow rate= Amps = I Resistance - limits the conductor's ability to allow the flow of electrons, and is expressed in ohms. = pipe size = Ohms =R Amps - The rate at which electricity flows through a conductor. I=W/E Electrical power - Is the amount of work that the electrical flow can do. This is expressed as watts or kilowatts (1,000 watts). (W) = E(I) Ohms Law - are basically a series of mathematical models that show us how to work out safe working loads for conductors and electrical components. When evaluating a elecrical supply - we need to recognize that copper and aluminum conductors are not the same, copper inherently has less resistance to the flow of electrons than aluminum does. For this reason, aluminum conductors are always one to two sizes larger than the equivalent copper one for any given amperage Service 100 Amps - #2 Aluminium, #4 Copper Service 110 Amps - #1 Aluminium, #3 Copper Service 125 Amps - 1/0 Aluminium, #2 Copper Service 150 Amps - 2/0 Aluminium, #1 Copper Service 200 Amps - 4/0 Aluminium, 2/0 Copper Service 250 Amps - 300 kcmil Aluminium, 4/0 Copper Service 400 Amps - 600 kcmil Aluminium, 400 kcmil Copper Small conductors commonly seen by home inspectors - 15 amps = #14 Copper, #12 Aluminium 20 amps = #12 Copper 25 amps = #10 Aluminium 30 amps = #10 Copper, #8 Aluminium The typical electrical service for homes in North America is - 120/240 An electrical circuit requires a minimum of - Two wires through which electric current flows. Current is measured in amperes, which travels from a power source (such as the local utility), through the device it operates, called the load, and then back to the source to complete the circuit. In AC or alternating -current wiring, there are about 120 volts in the "hot" or energized wire. This voltage provides the momentum that forces the electrons to flow in the circuit. Most 120 -volt circuits are wired to deliver 15 or 20 amps of current. According to InterNACHI's Home Inspection S.O.P ., the inspector is not required to: - 1. measure or determine the amperage or voltage of the main service equipment; 2. remove panelboard cabinet covers or dead fronts; 3. insert any tool, probe or device into the main panelboard, sub -panels, distribution panelboards, or electrical fixtures; or 4. operate any electrical disconnect or over -current protection devices. warning signs that a panel, box, or the system in general may be compromised, - 1. scorch marks on the dead front or the panelboard door, indicating a past or recent arc flash; 2. rust, which indicates past or recent moisture intrusion; 3. missing or open breakers that cannot be confirmed to be de -energized;

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur ACADEMICMATERIALS. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €7,80. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

77988 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!
€7,80
  • (0)
  Ajouter