EPA 608 Type 3 Exam Questions With Correct Answers On low pressure chillers, moisture typically enters the refrigerant system through - answerair leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: - answer10 psig Leak test and re...

[Montrer plus]

Aperçu 2 sur 10  pages

  • 28 août 2024
  • 10
  • 2024/2025
  • Examen
  • Questions et réponses
  • EPA 608
  • EPA 608
avatar-seller
©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM



EPA 608 Type 3 Exam Questions
With Correct Answers


On low pressure chillers, moisture typically enters the refrigerant system through - answer✔✔air
leaks from areas with gaskets or fittings

The maximum test pressure for leak testing a low pressure centrifugal is: - answer✔✔10 psig
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller -
answer✔✔...

A hydrostatic tube test kit is used to: - answer✔✔determine if a tube leaks
Commercial and industrial process refrigeration systems must be repaired when the leak rate
exceeds ____ of the charge per year. - answer✔✔35%

Refrigerant recovery typically start with liquid recovery it is faster. - answer✔✔...

A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - answer✔✔15
psig
According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a
level above ____ during a standing vacuum test, the system should be checked for leaks. -
answer✔✔2.5 mm Hg

The primary water source for a recovery unit condensing coil is _____. - answer✔✔local
municipal water supply
When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells
before changing with liquid? - answer✔✔16.9" Hg vacuum

After recovering the liquid refrigerant you must: - answer✔✔recover the vapor refrigerant
According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton
R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. - answer✔✔100
pounds

, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM


Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can
cause the: - answer✔✔system water to freeze

A system does not have to be evacuated all the way to the required level when: - answer✔✔leaks
in the appliance make evacuation to the prescribed level unattainable
Which of the foloowing repairs would ALWAYS be considered "major" under EPA's -
answer✔✔replacement of evaporator coil
Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of
opening the system for a non major repair? - answer✔✔warming the refrigerant
If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low
pressure appliance to _______ before making a major repair. - answer✔✔25 mm of Hg absolute

After reaching the required recovery vacuum on a chiller, you should - answer✔✔Wait for at
least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a
liquid form or in the oil

The pressure corresponding to 32 F for R-123 - answer✔✔20 inches of HG vacuum

When evacuating a system the use of too large a vacuum pump can cause? - answer✔✔trapped
water to freeze
Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: -
answer✔✔35F
During the evacuation of a system containing large amounts of moisture you can prevent
freezing of this moisture by increasing the pressure with______gas - answer✔✔nitrogen
ASHRAE standard 15-1994 requires that each machinery room must activate an alarm and
mechanical ventilation beofre refrigerant concentrations exceed: - answer✔✔the threshold limit
valve and time weighted average
The typical design burst pressure for a rupture disk on a low pressure centrifugal air-conditioning
system is set at_______ - answer✔✔15 psi
Heat pumps that have been retrofitted from R22 to R407C should be leak checked with: -
answer✔✔pressurized nitrogen

When a new system has been assembled, the first thing to do is: - answer✔✔pressurize the
system with inert gas and leak check
EPA regulations require that leaking commercial or industrial process refrigeration equipment
must be repaired when the leak rate exceeds______ of the charge per year. - answer✔✔35%

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur Thebright. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €12,20. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

79373 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!
€12,20
  • (0)
  Ajouter