Mosby CT Registry Review Questions and Answers 2024
11 vues 0 fois vendu
Cours
CT Registry
Établissement
CT Registry
Mosby CT Registry Review Questions and Answers 2024
What is the smallest component of a digital image
pixel
How many CT numbers are assigned to each pixel in the image matrix?
One
In a CT image, the CT number
Of a material is dependent on its linear attenuation coefficient
...
mosby ct registry review questions and answers 202
what is the smallest component of a digital image
how many ct numbers are assigned to each pixel in
as patient motion increases spatial resolution de
École, étude et sujet
CT Registry
CT Registry
Vendeur
S'abonner
julianah420
Avis reçus
Aperçu du contenu
Mosby CT Registry Review Questions
and Answers 2024
What is the smallest component of a digital image - answer pixel
How many CT numbers are assigned to each pixel in the image matrix? - answer One
In a CT image, the CT number - answer Of a material is dependent on its linear
attenuation coefficient
Each two-dimensional square of data that make up the CT image is called a - answer
pixel
What is an element of the digital image - answer pixel
Which of the following influences the spatial resolution in cardiac CT imaging -
answer*detector size
*reconstruction interval
*pitch
As patient motion increases spatial resolution decreases - answer TRUE
Which is an advantage of using a small focal spot - answer increased spatial resolution
Increasing the CT image matrix from 256x256 to 512x512 will likely improve? - answer
High-contrast spatial resolution
The practical limiting spatial resolution of a CT scanner is 3.6 lp/cm. What size object
does this correspond to? - answer1.4 mm
Use of a bone filter, as opposed to a soft tissue filter, to reconstruct CT images would
likely improve? - answer Spatial resolution
The spatial resolution of a typical CT scanner is on the order of? - answer1 mm
A 512 x 512 matrix CT image over a 30-cm field of view could show a spatial resolution
of no better than ? lp/cm? - answer8.5
When comparing a 512x512 matrix to a 1024x1024 matrix, the 1024x1024 matrix? -
answer Contains four times as many pixels: 1024 x 1024 =1048576 then 512 x 512=
262144...then divide 1048576 /262144 = 4
,High contrast spatial resolution and low contrast resolution are typically measured
baseline and? thereafter - answer Biannually
To improve the high contrast spatial resolution of a CT study, one would increase _____
while keeping all other factors the same. - answer Matrix size (128x128 to 512x512)
A radiologist wants to improve the high-contrast spatial resolution of anatomy which
he/she is examining by CT. The change which would best lead to this improvement is -
answer Increase the matrix size
To improve the high-contrast spatial resolution of a CT study, one could increase ?
while keeping all other factors the same? - answer Matrix size
A voxel contains 25% air, 50% water and 25% bone. The CT number for this voxel
would be expected to be _____ HU? - answer0
How many pixels are contained in a 1,024 matrix image? – answer D. 1,048,576
MATH 1024 X1024
It is located in a matrix and is a two dimensional representation of a voxel - answer pixel
When CT numbers are calculated for voxels (volume elements) of tissue what is
assigned the calculated number and a subsequent shade of gray - answer pixel
What is defined as a picture element or the smallest component of the digital image -
answer pixel
A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter FOV.
Each pixel is approximately _____ mm on a side. - answer0.6 equation:
30cm/512= .058cm convert to mm and its .58 which is approximately 0.6
The ability of a system to define small objects distinctly is referred to as which of the
following? - answer spatial resolution
Which of the following terms is/are commonly used to describe a CT scanner's ability to
differentiate objects with similar linear attenuation coefficients - answer*spatial
resolution
*sensitivity
Which of the following factors have an affect on contrast resolution - answer*patient size
*slice thickness
*pixel size
*mAs/dose
As mAs/dose increases contrast resolution INCREASES - answer TRUE
The ability of a CT scanner to accurately image objects with similar densities is termed -
answer*contrast resolution
*sensitivity
Which of the following has a direct relationship on increasing contrast resolution -
answer*mAs/dose increase
*Slice thickness
For a particular CT scanner's beam quality, the linear attenuation coefficient for water is
0.20 cm-1 and for a certain tumor is 0.21 cm-1. What is the CT number of the tumor? -
answer50. Equation (.21-.20/.21) × 1000= 50
A CT scanner with poor contrast resolution or low sensitivity has difficulty separating -
answer tissues whose linear attenuation coefficients are nearly equal
What is the basic physical quantity being measured by a CT system - answer Linear
attenuation coefficient
Assume the linear attenuation coefficient is 0.20 cm-1 for water and 0.40 cm-1 for tissue
within a given voxel. What is the CT number in Hounsfield units for the pixel
representing this voxel? - answer+1,000....Equation { (.4-.2) /.2} x 1000
What fraction of monoenergetic x-rays will be absorbed by a 20-cm thick material
having a linear attenuation coefficient of 0.05 cm-1? - answer0.63
The contrast resolution of CT is approximately ? % - answer0.3 to 0.6
This term describes the ability CT scanner to differentiate objects with MINIMAL
differences in attenuation coefficients - answer contrast resolution
What is the term for resolution of a CT scanner referred to as the system's ability to
differentiate objects with SIMILAR densities. - answer contrast resolution
In order to pass ACR CT accreditation, the CT scanner's adult head protocol must be
within - answer1.0
The QC test for the average CT number for water should be done - answer Daily
The following are all basic tenets of a QC program for computed tomography scanner -
answer*QC test must be conducted regularly
*Accurate record keeping
*all test results must be interpreted promptly
, Using the ACR CT accreditation phantom, module 3 is used to measure which of the
following - answerCT number uniformity
The following QC test should be done on a monthly basis - answerhigh contrast
resolution
The CT number at the center of a uniformly filled water phantom should ideally be -
answer0
The ACR CT accreditation phantom is designed to perform QC measurements of -
answer*positioning accuracy and light accuracy alignment only
*CT number accuracy and slice thickness only
*low contrast resolution, CT number uniformity, and high contrast resolution
The ACR tolerance limit for the CT number accuracy for water is - answer+-7HU or +-5
preferred
The test for the average CT number of water should be tested at - answer*acceptance
*daily
The ACR tolerance limit for the CT number uniformity is which of the following -
answerThe center CT number must be between plus or minus 7HU plus the abdomen
protocol must be used
To evaluate low contrast resolution, phantoms are scanned using different ? settings -
answermAs
For an increase from 200 mA to 400 mA in a CT exam, the result would be to -
answerIncrease low contrast resolution
This ability is also commonly referred to as the low contrast resolution or the sensitivity
of the CT scanner - answercontrast resolution
The major advantage of a CT scanner over a screen-film radiography system is -
answerBetter low contrast discrimination
For CT images, all of the following factors improve the visibility of large, low-contrast
lesions except? - answerSmaller pixel sizes
As the iodine concentration ? the viscosity of the substance will ? - answerincrease,
increase
A fluid with a high viscosity is relatively - answerthick and flows slowly
The viscosity of a solution may be changed by regulating - answertemperature
Les avantages d'acheter des résumés chez Stuvia:
Qualité garantie par les avis des clients
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
L’achat facile et rapide
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Focus sur l’essentiel
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Foire aux questions
Qu'est-ce que j'obtiens en achetant ce document ?
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Garantie de remboursement : comment ça marche ?
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Auprès de qui est-ce que j'achète ce résumé ?
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur julianah420. Stuvia facilite les paiements au vendeur.
Est-ce que j'aurai un abonnement?
Non, vous n'achetez ce résumé que pour €17,54. Vous n'êtes lié à rien après votre achat.