allowable materials for the DWV system "underground"
1-1/4" - 1 dfu's
1-1/2" - 3 dfu's
2" - 4 dfu's
3" 6 dfu's
4" - dfu's - ANSWER-What are the fixture unit values for the following traps
,Double fixture fitting - ANSWER-What type of fitting is used for continuous
waste and venting of lavatories back to back?
1" - ANSWER-Caulk joints for cast iron bell and spigot shall be filled with
molten lead to a depth of not less than ________?
Wye, Combination Wye w/ 1/8 bend, Long sweep - ANSWER-What type of
fitting or fittings can be used to connect horizontal drainage to another
horizontal drainage line?
- Each horizontal drainage pipe shall be provided with a cleat at its upper
terminal
- Horizontal run more than 100'
- Each horizontal change of direction exceeding 135°
- Front Main Cleanout - ANSWER-Cleanout locations required by code
2" - ANSWER-What is the minimum size discharge pipe for an ejector
installed in a single dwelling?
2" - ANSWER-The lowest inlet connected to the ejector pump shall have a
clearance of not less than ____ from the high water or starting level of the
sump.
,Yes, with prior approval of the AHJ - ANSWER-Can macerating toilet systems
be installed instead of a sewage pump system
3/4" - ANSWER-What is the minimum size discharge pipe for a macerating
toilet system
100' - ANSWER-Maximum distance a cleanup can be spaced apart
12"
18" - ANSWER-Minimum clearance in front of a cleanup for 2" or less
Minimum clearance in front of a cleanup for 2" or more
20' - ANSWER-Underfloor cleanup shall not be located more than _____ from
an access door, trap door, or crawl hole
Back Water Valve - ANSWER-When plumbing fixtures are installed on a floor
level lower than the next upstream manhole cover of the sewer, such
drainage piping shall be protected from backflow of sewage by a ____________
, 20 - ANSWER-Sewage ejectors receiving the discharge of water closets or
ruinals shall have a discharge capacity not less than ___ gallons per minute
1/4" per foot - ANSWER-What is the minimum pitch required fora 2"
horizontal drain?
Swing check valve - ANSWER-The discharge line from an ejector pump shall
be provided with an accessible ___________ and gate or ball valve.
Downstream of the backwater valve - ANSWER-Where shall the gate valve be
located on the discharge line on an ejector pump
8' - ANSWER-Drainage connections shall not be made into a drainage piping
system within ________ of an vertical or horizontal change in direction of a
stack containing suds producing fixtures.
10' Head of water for 15 minutes
5 psi for and air test - ANSWER-What are the requirements when testing the
DWV system Water and Air?
Les avantages d'acheter des résumés chez Stuvia:
Qualité garantie par les avis des clients
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
L’achat facile et rapide
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Focus sur l’essentiel
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Foire aux questions
Qu'est-ce que j'obtiens en achetant ce document ?
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Garantie de remboursement : comment ça marche ?
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Auprès de qui est-ce que j'achète ce résumé ?
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur NursingTutor1. Stuvia facilite les paiements au vendeur.
Est-ce que j'aurai un abonnement?
Non, vous n'achetez ce résumé que pour €15,21. Vous n'êtes lié à rien après votre achat.