Examen
EEG Study Guide for registry (ASET Review Questions and Answers)
EEG Study Guide for registry (ASET Review Questions and Answers)
[Montrer plus]
Publié le
23 octobre 2024
Nombre de pages
28
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses
Établissement
EEG
Cours
EEG
S'abonner
Envoyer un Message
€12,66
Egalement disponible en groupe à partir de €41,40
Ajouté
Ajouter au panier
Ajouter au liste de veux
Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien
Document également disponible en groupe (1)
Electroencephalography (EEG) Exam Bundle 2024-2025
€ 523,77
€ 41,40
47 éléments
1. Examen - Abret eeg test questions and answers
2. Examen - Anatomy and physiology eeg lab exam questions and answers
3. Examen - Chapter 1 eeg; sensory & cognitive erps exam questions and answers
4. Examen - Definitions for eeg – eeg exam questions and answers
5. Examen - Eeg 101 final exam with complete solutions
6. Examen - Eeg 203 final review exam with correct answers (graded a)
7. Examen - Eeg 210- final exam review questions and answers
8. Examen - Eeg 211 final exam review questions and answers
9. Examen - Eeg board exam questions and answers 2024-2025
10. Examen - Eeg board exam questions and answers
11. Examen - Eeg board exam with correct answers 2024-2025
12. Examen - Eeg board prep (part 1) exam questions and answers
13. Examen - Eeg board prep asap test prep questions and answers
14. Examen - Eeg board prep exam questions and answers
15. Examen - Eeg board prep mock exam -2 questions and answers
16. Examen - Eeg board prep practice questions and questions (graded a)
17. Examen - Eeg boards mock exam questions and answers
18. Examen - Eeg boards part 2 practice test with correct answers
19. Examen - Eeg chapters 1-7, 9-13 exam questions and answers
20. Examen - Eeg exam questions and answers
21. Examen - Eeg exam questions with correct answers
22. Examen - Eeg final exam (end 201, 202, and 203) questions and answers
23. Examen - Eeg lesson 1 exam questions and answer
24. Examen - Eeg mock exam questions and answers
25. Examen - Eeg mock exam questions and answers 2024-2025
26. Examen - Eeg review questions 1-150 exam questions and answers
27. Examen - Eeg semester 1 102-2 exam with correct answers
28. Examen - Eeg study guide for registry (aset review questions and answers)
29. Examen - Eeg terminology set 1 with correct answers
30. Examen - Electroencephalogram (eeg) and event related potentials (erps) exam questions and ans...
31. Examen - Electroencephalographic (eeg) recording and epilepsy exam questions with correct answ...
32. Examen - Electroencephalography (eeg) & evoked potentials exam questions and answers
33. Examen - Electroencephalography (eeg) - clinical skills ii fall exam questions and answers
34. Examen - Electroencephalography (eeg) exam questions and answers
35. Examen - Electroencephalography (eeg) exam questions and answers
36. Examen - Electroencephalography (eeg) exam questions and answers
37. Examen - Electroencephalography exam questions and answers
38. Examen - Electroencephalography lab exam with correct answers
39. Examen - Lab -9 electroencephalography (eeg) exam questions and answers
40. Examen - Lab 4 electroencephalography (eeg) exam questions and answers
41. Examen - Lecture 3 & 4 electroencephalography (eeg) exam questions and answers
42. Examen - Midterm exam normal electroencephalography questions and answers
43. Examen - Physiology - electroencephalography (eeg) (b7) exam questions and answers
44. Examen - Prep u ch. 65electroencephalogram (eeg) exam questions and answers
45. Examen - The electroencephalogram (eeg) and measuring brain waves exam 2024-2025 questions and...
46. Examen - Eeg (electroencephalography) exam questions and answers
47. Examen - Exam 1 eeg exam questions and answers
Montrer plus
EEG Study Guide for registry (ASET
Review Questions and Answers)
The iibasic iiunit iifor iimeasuring iicurrent iiflow iiis? ii- iiAnswers ii-Ampere
The iibasic iiunit iiof iiresistance? ii- iiAnswers ii-Ohm
Which iiof iithe iifollowing iiis iinot iia iivalid iiexpression iiof iiOhm's iilaw?
A. iiR=EI iior iiR=VI
B. iiE=IR iior iiV=IR
C. iiI=E/R iior iiI=V/R
D. iiR=E/I iior iiR=V/I ii- iiAnswers ii-A. iiR=EI iior iiR=VI
Which iiof iithe iifollowing iiis iinot iia iiunit iifor iimeasuring iialternating iifrequencies?
A. iiCycles iiper iisec
B. iiVolts
C. iiHertz
D. iiKilocycles ii- iiAnswers ii-B. iiVolts
Which iiof iithe iifollowing iidescribes iithe iiaction iiof iia iicapacitor?
A. iiopposes iichanges iiin iicurrent iiflow
B. iiconverts iialternating iicurrent iito iidirect iicurrent
C. iicreates iidirect iicurrent iiresistance
D. iistores iienergy ii- iiAnswers ii-D. iistores iienergy
What iiis iia iifilter? ii- iiAnswers ii-A iicircuit iithat iiallows iisome iifrequencies iito iipass iithrough
iiit, iiwhile iiothers iiare iiblocked
What iiis iian iiamplifier? ii- iiAnswers ii-A iicombination iiof iielectronic iicomponents iidesigned
iito iiincrease iithe iipower, iivoltage iior iicurrent iiof iia iisignal.
A iismall iifluctuating iioutput iirecorded iiby iithe iiEEG iiinstrument iieven iiwhen iithere iiis iino
iiinput iisignal iiis iicalled:
a. iioutput iivoltage
b. iilinear iidistortion
c. ii60Hz iiinterference
d. iinoise ii- iiAnswers ii-D. iinoise
The iiEEG iiamplifier iiis iidesigned iiso iithat iiwhen iiinput ii1 iiis iimore iinegative iithen iiinput
ii2, iithe iideflection iiwill iibe? ii- iiAnswers ii-Upward
,What iiis iicommon iimode iirejection? ii- iiAnswers ii-the iicharacteristic iiof iian iiamplifier iithat
iirejects iiexternal iiinterference
Which iiof iithe iifollowing iiis iimost iiattenuated iiby iia iilow iifrequency iifilter iiof ii1 iiHz?
A. ii.5hz
B. ii5hz
C. ii10 iihz
D. ii.1hz ii- iiAnswers ii-D. ii0.1hz
Time iiconstant iiis iidefined iias iithe iitime iirequired ii- ii- iiAnswers ii-for iithe iideflection iito
iifall ii(decay) iito ii37% iiof iithe iipeak iideflection.
A iihigh iifrequency iisetting iiof ii35hz iiwould iiattenuate ii50hz iimuscle iiactivity iiby
iiapproximately iiwhat iipercentage? ii- iiAnswers ii-40%
According iito iiACNS iiGuidelines, iirecording iiclinical iiEEG iion iidigital iimedia iirequires
iimonitors iito iihave? ii- iiAnswers ii-Between ii25 iiand ii35 iimm/second iihorizontal iiscaling
iiand iia iiminimum iiof ii100 iidata iipoints/second iito iiaccurately iidisplay iiEEG iion iithe
iimonitor iiscreen.
The iifilter iicreating iia iivery iinarrow iiband iipass iithat iishould iirarely iibe iiused iiclinically-
a. iiLF ii5.0 iiand iiHF ii70hz
b. iiLF ii5.0 iiand iiHF ii15hz
c. iiLF ii0.1 iiand iiHF ii70hz
d. iiLF ii0.1 iiand iiHF ii15hz ii- iiAnswers ii-B. iiLF ii5.0 iiand iiHF ii15hz
During iithe iirecording iiof iicerebral iiactivity, iithe iicalibration iiinput iivoltage iiis iichanged
iifrom ii50uv iito ii100uv. iiWhat iiwill iibe iithe iiresult?
A. iino iieffect iion iithe iiactivity iibeing iirecorded
B. iia iitwo iifold iiincrease iiin iiamplitude
C. iia iione iihalf iireduction iiof iiamplitude
D. iiclipping iiof iithe iiwaveform ii- iiAnswers ii-A. iino iieffect iion iithe iiactivity iibeing iirecorded
According iithe iiACNS iiguidelines ii2006, iithe iiminimum iisampling iirate iifor iiEEG iiData,
iishould iibe iiat iileast____________times iithe iihighest iihigh iifrequency iifilter iisetting. ii-
iiAnswers ii-Three
In iia iirecord iiwith ii10hz iialpha iiactivity. iiWhen iithe iidisplay iiepoch iiis iichanged iifrom ii10
iiseconds iiper iidisplay iiscreen iito ii20 iiseconds iiper iidisplay iiscreen, iithe iifrequency iiof
iithe iiactivity iiwill iibe________ ii- iiAnswers ii-10hz
Guidelines iifor iirecording iidigital iiEEG iiare iiwritten iiby: ii- iiAnswers ii-The iiamerican
iiclinical iineurophysiology iisociety ii(ACNS)
The iiterm iiRAM iimeans: ii- iiAnswers ii-TEMPORARY iiMEMORY iiSTORAGE iiTHAT iiIS
iiCRITICAL iiTO iiRAPID iiCOMPUTER iiOPERATIONS
, Three iibasic iicomputer iiports iiare: ii- iiAnswers ii-serial, iiparallel, iiusb
The iibest iimetals iifor iiclinical iiEEG iirecording iiare_________? ii- iiAnswers ii-Silver-silver
iichloride, iiplatinum iior iigold
Which iiof iithe iifollowing iiis iinot iirelated iito iimeasuring iielectrode iiresistance?
A. iiopposition iito iidirect iicurrent iiflow
B. iimeasurement iiwhile iithe iielectrode iiis iiunattached iito iithe iiscalp
C. iimeasurement iiwith iian iiohmmeter
D. iiopposition iito iialternating iicurrent iiflow ii- iiAnswers ii-D. iiopposition iito iialternating
iicurrent iiflow
The iielectrode iisite iithat iiis iilocated ii1cm iiabove, iione iithird iithe iidistance iiout iifrom iithe
iileft iiexternal iiauditory iimeatus iitoward iithe iileft iiouter iicanthus iiis iicalled? ii- iiAnswers ii-
T1 iior iiF9
Due iito iia iicentral iiscalp iilesion, iiC4 iihas iito iibe iirelocated ii4mm iianteriorly. iiThe
iitechnologist iishould:
a. iirelocate iiC3 ii4mm iianteriorly
b. iimake iino iiother iiplacement iichanges
c. iirelocate iiP3 ii4mm iianteriorly
d. iirelocate iiall iielectrodes iiin iithe iiright iiparasagittal iiplane ii4mm iianteriorly ii- iiAnswers ii-
a. iirelocate iiC3 ii4mm iianteriorly
A iipatient iican iibecome iithe iipathway iifor iileast iiresistance iiand iitherefore iielectically
iisusceptable iito iishock iiwhen;
a. iithe iirecording iiinstrument iiis iiturned iion
b. iithe iielectrode iitest iiis iiutilized
c. iidepth iielectrodes iiare iiused
d. iithe iipatient iihas iian iiindwelling iiheart iicatheter ii- iiAnswers ii-d. iithe iipatient iihas
iiindwelling iiheart iicatheter
Eye iileads iiplaced iiat iithe iiouter iicanthus iiof iieach iieye iiwill iirecord:
a. iiall iieye iimovements
b. iihorizontal ii& iivertical iieye iimovements
c. iionly iivertical iieye iimovements
d. iimainly iihorizontal iieye iimovements ii- iiAnswers ii-d. iimainly iihorizontal iieye
iimovements
which iiof iithe iifollowing iiis iinot iia iiphysiological iiartifact?
a. iiperspiration
b. iiglossokinetic iiresponse
c. ii60hz iiinterference
d. iieye iimovement ii- iiAnswers ii-c. ii60hz iiinterference