Absorptiometry - Answer - a method for measuring bone mineral density using the
attenuation of x-ray or gamma radiation
Accuracy - Answer - the degree to which a measurement value estimates the actual
value of the quantity being measured
- often presented in percentage or absolute difference
Accuracy Calibration of Industry Standard - Answer - bone: hydroxyapatite
- fat: stearic acid
- lean soft tissue 0.6% sodium chloride solution
Age-Matched - Answer - comparison of the patient's BMD to a reference population of
the same age
Air Ratio - Answer - value derived from the Quality Assurance procedure which
indicates the quotient of the air value
- (air value @ 70keV) / (air value @ 38keV) for the scan table
Application - Answer - a set of instructions or a program that performs work unrelated to
the actual operation of a computer itself
- programs that operate bone densitometers and analyze the data
Archiving - Answer - saving scan images to another drive or media
Array Detector - Answer A grid or series of discrete solid state electronics capable of
converting x-rays into electronic pulses
, Background Counts - Answer - a measurement of environmental radiation
- includes leakage from the x-ray source
- taken during the systems QA procedures and obtained while the source is occluded by
the lead shutter
Back Up File - Answer - a copy of the data and other computer information
- done to protect the data and information in case of a loss of the original files
Body Composition - Answer - the process of dividing the body weight into compartments
- typically divided into: bone, lean tissue, fat tissue
- recorded in grams or percentage
Bone Area - Answer - bone projection area measured in units of centimeters (SPA) or
centimeter squared (DPA or DXA) by a densitometer
Bone Mineral Content (BMC) - Answer - measured amount of mineral in grams
determined by absorptiometry
Bone Mineral Density (BMD) - Answer - amount of mass per square centimeter of bone
measured by a densitometer
Broker - Answer - a computer that converts one type of data from a source computer
into a version suitable for use by another.
- electronic version of a translator
Broadband Ultrasound Attenuation (BUA) - Answer - a parameter measured by
quantitative ultrasound
- quantifies the energy lost from the sound wave as it passes through bone
Les avantages d'acheter des résumés chez Stuvia:
Qualité garantie par les avis des clients
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
L’achat facile et rapide
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Focus sur l’essentiel
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Foire aux questions
Qu'est-ce que j'obtiens en achetant ce document ?
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Garantie de remboursement : comment ça marche ?
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Auprès de qui est-ce que j'achète ce résumé ?
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur Braxton. Stuvia facilite les paiements au vendeur.
Est-ce que j'aurai un abonnement?
Non, vous n'achetez ce résumé que pour €9,78. Vous n'êtes lié à rien après votre achat.