Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien
logo-home
MASTER ELECTRICIAN EXAM REVIEW QUESTIONS €12,17   Ajouter au panier

Examen

MASTER ELECTRICIAN EXAM REVIEW QUESTIONS

 7 vues  0 fois vendu
  • Cours
  • Master electrician license
  • Établissement
  • Master Electrician License

MASTER ELECTRICIAN EXAM REVIEW QUESTIONS

Aperçu 2 sur 12  pages

  • 15 novembre 2024
  • 12
  • 2024/2025
  • Examen
  • Questions et réponses
  • Master electrician license
  • Master electrician license
avatar-seller
MASTER ELECTRICIAN EXAM REVIEW QUESTIONS
branch circuit - Answers- That portion of a wiring system extending beyond the final
overcurrent device is called the:

Calculated load - Answers- The final sum of the computed loads, based on the
minimum code requirements, is the

Resistance - Answers- As compared to #10, a #8 wire of the same Iength has less:

0.001 inch - Answers- One circular mil is the area of a circle whose diameter is:

1,000,000 cm - Answers- A round bus-bar one inch in diameter, has a circular mil area
of:

carnival is not required for equipment at circuit if the receptacle is of the
____________type

not less than 1 1/4 in. from - Answers- Where cables or nonmetallic raceways are
installed through bored.holes in joists, rafters, or wood members;holes shall be bored so
that the edge of the hole is the nearest edge -of the wood member.

located on a balcony accessible only to qualified persons
located in a room only accessible to
qualified persons
elevated 8 ft or more above floor or other working surface - Answers- To guard live
parts over 50V but less than 600V, equipment is permitted to be

12Ft - Answers- Overhead feeder conductors shall have a minimum __________
vertical clearance over residential property and driveways, as well as those commercial
areas not subject to truck traffic, where the voltage is limited to 300 volts-to-ground.

36 inches - Answers- Where rear access is required to work on de-energized parts on
the back of enclosed equipment, a minimum working space of horizontally shall be
provided.

50' - Answers- What is the maximum run length of a 18AWG fixture wire that is tapped
on to a 20 amp branch circuit?

power supply failure - Answers- When the service disconnecting means is a power-
operated switch or circuit breaker, it shall be able to be opened by hand in the event of a

2 in of concrete - Answers- Conductors are considered outside a buildings when they
are buried under not less than

, 8 - Answers- In straight pull, the length of the box shall not be less than. ____times the
trade size of the largest raceway.

four times as great - Answers- A copper wire with twice the diameter of another wire
has a current carrying capacity:

10.4 - Answers- The specific resistance of copper wire @ 20° C in ohms per circular mil
ft. is

permit current to flow - Answers- Conductance of an electric circuit is that property that
will:

1O ohms - Answers- The equivalent value of 0.1 mho is

directly proportional to its length - Answers- The resistance of copper wire is:

Feeder - Answers- The portion of a wiring system between a point of distribution and
the branch circuit overcurrent device is

locking - Answers- GFCI protection at a

18" - Answers- At least one receptacle outlet shall be installed within of the top of a
show window for each 12 linear feet measured horizontally across its length

1000A - Answers- Ground-fault protection of equipment shall be provided fro solidly
grounded wye electrical services of more than 150 volts-to-ground, but not exceeding
600V phase-to..phase for each service disconnecting means rated

18" - Answers- Receptacle outlets in floors shall not be counted as part of the required
number of receptacle outlets unless located within ______ of the wall

50V - Answers- Exposed live parts of motors and controllers operating at or more
between terminals shall be guarded against accidental contact by enclosure or by
location

5' - Answers- Lighting track shall not be installed less than______ above the finished
floor except' where protected from physical damage or where the track operates at less
than 30 V rms, open-circuit voltage

4 - Answers- Each general care area patient bed location shall be provided with a
minimum of_______receptacles, which can be single, duplex, or a combination with
each duplex counting as two receptacles

Combination Range hood/ Microwave
oven - Answers- In a Dwelling Unit which appliance is allowed to have a 24" cord with
attachment ground plug?

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur Greaterheights. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €12,17. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

62890 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!
€12,17
  • (0)
  Ajouter