S12 Sprinkler Test, S13 Standpipe Test, Sprinklers Segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS (Certificate Of Fitness)
fire department connection ✔ Ans - normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies.
system control valve ✔ Ans - valve controlling flow to water-based fire protection systems.
fire command center ✔ Ans - Designated room or area in a structure where the status of the fire detection, alarm, and protection systems is displayed and the systems can be manually controlled.
Fire pump, automatic standpipe. ✔ Ans - A fire pump located at or below street level that supplies the lower 300 feet (91.4 m) of a standpipe system or a combined standpipe and sprinkler system.
tags ✔ Ans - on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational
Green tag ✔ Ans - no impairment found in entire system- main control valve
red tag ✔ Ans - place on main control valve if FULLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational
blue disk ✔ Ans - partially out of service- on all fire department connections
water storage tank ✔ Ans - Collects cooled water OS & Y valve ✔ Ans - indicating type of control valve used for fire sprinkler system
deluge valve ✔ Ans - water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO
deluge sprinkler system ✔ Ans - employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached.
Early suppresion fast response sprinklers ✔ Ans - fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards
extra large orifice sprinklers ✔ Ans - = or > 1 inch less pressure to achieve a given discharge density
extended coverage sprinkler ✔ Ans - 400 max square feet discharge 20
foot by 20 foot spacing between sprinklers
fire pump ✔ Ans - a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected to public
water source or tank. provides higher pressure to sprinkler system
Glass bulb sprinkler ✔ Ans - operated by heat breaking a glass bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for standard response
hose valve ✔ Ans - valve to additional hose connection
hydraulic placard ✔ Ans - sign attached to a hydraulically calculated sprinkler system indicating the design density, required gallons per minute and pressure for the system to operate properly hydraulically calculated systems ✔ Ans - method of sizing auto sprinkler piping using a prescribed amount of water to be distributed over a specific area.
impairment coordinator ✔ Ans - in charge of safety during out of service systems
intermediate level sprinkler ✔ Ans - sprinkler equipped with integral shields to protect the operating elemtn form discharge from sprinklers installed at higher elevations
large orifice sprinkler ✔ Ans - sprinkler head with orifice size equal or greater than 3/4 and less than 1 inch
listed device ✔ Ans - A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common.
Master Pressure Reducing Valve ✔ Ans - A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone.
Main Drain ✔ Ans - The primary drain connection located on the system riser and also utilized as a flow test connection.
Microbiologically Influenced Corrosion (MIC) ✔ Ans - Corrosion caused by the presence of microbes in the water supply that over time attack the interior of metallic piping and cause leaks, pitting, and blockages.
Old-Style/Conventional Sprinkler ✔ Ans - A sprinkler that directs 40% to 60% of the water initially in a downward direction and is designed to be installed with the deflector in either the upright or pendent position.
Pendent Sprinkler ✔ Ans - A sprinkler designed to be installed in such a way that the water stream is directed downward against the deflector. Pintle Screws ✔ Ans - A visual indicating device required for sprinklers
manufactured prior to 1999 identifying small orifice sprinklers and large orifice sprinklers where orifice size is different than the nominal thread size of the sprinkler head.
Pipe Schedule Systems ✔ Ans - A method of sizing piping based upon the number of sprinkler heads and the occupancy of the protected area.
Preaction Sprinkler System ✔ Ans - A sprinkler system employing automatic sprinklers that are attached to a piping system that contains air that may or may not be under pressure, with a supplemental detection system installed in the same areas as the sprinklers.
Pressure Control Valve ✔ Ans - A pilot operated pressure reducing valve that may be used with a fire or booster pump designed for the purpose of preventing the incoming water supply pressure from dropping below a set pressure.
Pressure-Reducing Valve ✔ Ans - A valve designed for the purpose of reducing the downstream water pressure under both flowing (residual) and nonflowing (static) conditions.
Pressure Relief Valve ✔ Ans - A valve designed for the purpose of releasing excess air or water pressure from the Fire Protection Piping System.
Pressure Tank ✔ Ans - A tank using air pressure to supplying water for water-based fire protection systems. Tank contents to be maintained at one
third air to two thirds water.
Quick Response Sprinkler Head ✔ Ans - A sprinkler having a fusible link with a response time index (RTI) of 50 or less.
Recessed Sprinkler ✔ Ans - A sprinkler in which all or part of the body, other than the shank thread, is mounted above the ceiling.
Residential Sprinkler ✔ Ans - A type of fast response sprinkler that has
been specifically tested to enhance survivability in the room of fire origin and listed for use in dwelling units.
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
√ Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper LeCrae. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €17,10. Je zit daarna nergens aan vast.