NICET LEVEL STUDY GUIDE 1 EXAM 100 When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inc€12,31
In winkelwagen
NICET LEVEL STUDY GUIDE 1 EXAM 100 When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inc
5 keer bekeken 0 keer verkocht
Vak
Nicet
Instelling
Nicet
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level
(NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inches
If combination audible/visible appliances are installed the location o...
ck
QUESTIONS WITH
DETAILED ANSWERS | A+
lo
GRADE ASSURED //
yc
LATEST
ud
st
, When testing a water level supervisory switch serving a pressure tank a signal shall indicate if
the water level _____________from the required level
(NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inches
If combination audible/visible appliances are installed the location of the installed appliance shall
be determined by the requirements of _______.
ck
(Nfpa 72 18.4.8.1) - ANS the visible appliance
What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT?
(Nec Annex C tables) - ANS 26
lo
Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their
equivalent resistance? - ANS 150 ohms
yc
The room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat
detector has been selected that is listed for a 50' maximum spacing between detectors.
According to NFPA 72 how many detectors will be needed to protect this room?
x = - ANS 12
ud
According to NFPA 72 the minimum number of restorable fixed temperature spot type heat
detectors that must be tested during each annual test is?
(NFPA 72 14.4.4.5.1) - ANS Two detectors or more on each initiating device circuit
st
According to NFPA 72 how many spot type heat detectors are required for a space that is 80'
long and 55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space
between detectors of 30' - ANS 6
What color code requirement for a spot type heat detector rated at 200゚F - ANS White (NFPA
72, Table 17.6.2.1)
Unless otherwise recommended by the manufacturers published instructions, single and
multiple stations smoke alarms installed in one and 2 family dwellings shall be replaced every -
ANS 10 years from the day-of manufacture. (NFPA 72, 14.4.7.1)
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
√ Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Studyclock. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €12,31. Je zit daarna nergens aan vast.