Category 1 - Category of Water that originates from sanitary water source (Clean) Catetroy 2 - Category of Water that is contaminated; may cause discomfort or sickness (Grey) Category 3 - Category of Water that is grossly contaminated; includes toxins, pathogens Special Situation - Regulat...

[Meer zien]

Voorbeeld 4 van de 32  pagina's

  • 21 juli 2023
  • 32
  • 2022/2023
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
Alle documenten voor dit vak (230)
avatar-seller
Classroom
ASD Practice Tests Questions With
Complete Solutions

Category 1 - Category of Water that originates from sanitary
water source (Clean)

Catetroy 2 - Category of Water that is contaminated; may cause
discomfort or sickness (Grey)

Category 3 - Category of Water that is grossly contaminated;
includes toxins, pathogens

Special Situation - Regulated or hazardous materials

Class 1 - Class of water that has least amount of water,
absorption and evaporation

Class 2 - Class of water that has large amount of water,
absorption and evaporation (carpet; cushion; base of walls)

Class 3 - Class of water that is the greatest amount of water,
absorption and evaporation (ceiling; walls; insulation; flooring)

Class 4 - Class of water - Hardwood; plaster; concrete - Deep
pockets of saturation

Principles of Drying - Remove excess / Evaporation /
Dehumidification (Ventilation) / Temperature Control

,Light Wand - Extraction Tool - Perimeter of water loss; extract
glue-down carpets

Stationary Tool (Water Claw) - Extraction Tool - Subsurface
Tool; Extract Carpet and Cushion.

Self-Propelled Tools - Extraction Tool - (Rober; Xtreme
Xtractor) - Riding Tool; multi-speed; extract carpet and cushion.

Vacuum Squeegee - Extraction Tool - Concrete; hardwood;
vinyl; laminate;

Airmovers - Evaporation Tool - centrifugal (laminar); axial
(high-amperage; low amperage; focus ability)

1 per 10-16 linear ft. of wall area; 15-45 degree focus; almost
touching wall. - Placement of Airmovers

Structural Cavity Drying Systems - (SCDS)
vented (turbovents 18" - 48" widths' Octidry; Air Wolf
injected (Injectidry; Dri-Force; Direct-it In)

Floor Drying System - vented (Air Wolf)
Injected - negative air mats (Dri-Force; Injectidry)

Air Filtration Devices - AFDs (negative air machines; air
scrubbers; HEPA filters)

AHAM Rating - On dehumidification equipment it is the pints
removed at 80 degrees and 60% humidity in 24 hours.

,Standard Refrigerant - Temperature - 68 degress
Relative Humidity - 60%
Specific Humidity (gpp) - 55-60

Conventional - Temperature - 33 degrees
Relative Humidity - 40%
Specific Humidity (gpp) - 55-60

Low Grain Refrigerant (LGR) - Temperature - 40 degrees
Relative Humidity - 30%
Specific Humidity (gpp) - 28-35

Desiccant - Temperature - 32 degrees
Relative Humidity - 10% - below
Specific Humidity (gpp) - 10-15 - below

Refrigerants - Dehumidifiers that are most efficient operating
conditions 70-90 degrees (most energy efficient)

Desiccants - Dehumidifiers that are most efficient with incoming
air from coolest/driest air possible; capable of creating pressure
differentials; produces low specific humidity required to dry
Class 4 materials.

Conventional - Initial Dehumidification Calculations
Class 1 = 100
Class 2 = 40
Class 3 = 30
Class 4 = N/A

, LGR - Initial Dehumidification Calculations
Class 1 = 100
Class 2 = 50
Class 3 = 40
Class 4 = 50

Desiccant - Initial Dehumidification Calculations
Class 1 = 1 ACH
Class 2 = 2 ACH
Class 3 = 3 ACH
Class 4 = 2 ACH

Amperes (amperage or amps) - The amount of electricity
(current) flowing in a circuit

Voltage - The force of electricity flow in a circuit

Watts - The amount of electricity an electrical devices uses
when operating

BTUs (British Thermal Units) - Heat generated by electrical
device.

amps x volts x 3.4 - BTUs per hour formula

12,000 - HVAC removes _________ BTUs per ton.

15 - Residental is generally ___ amp

20 - Commerical is generally ___ amp

Dit zijn jouw voordelen als je samenvattingen koopt bij Stuvia:

Bewezen kwaliteit door reviews

Bewezen kwaliteit door reviews

Studenten hebben al meer dan 850.000 samenvattingen beoordeeld. Zo weet jij zeker dat je de beste keuze maakt!

In een paar klikken geregeld

In een paar klikken geregeld

Geen gedoe — betaal gewoon eenmalig met iDeal, creditcard of je Stuvia-tegoed en je bent klaar. Geen abonnement nodig.

Direct to-the-point

Direct to-the-point

Studenten maken samenvattingen voor studenten. Dat betekent: actuele inhoud waar jij écht wat aan hebt. Geen overbodige details!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Classroom. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €12,75. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 69052 samenvattingen verkocht

Opgericht in 2010, al 15 jaar dé plek om samenvattingen te kopen

Begin nu gratis
€12,75  1x  verkocht
  • (0)
In winkelwagen
Toegevoegd