Buildings that contain materials that pose a detonation hazard shall be classified as
Group ____ Answer- GROUP H-1

A group I-1 occupancy shall include a building or part thereof for more than ____
persons who reside on a 24-hour basis in a supervised environment and receive
custodial care. Answer- 16

Semiconductor fabrication facilities and comparable research and development areas in
which hazardous production materials (HPM) are used are classified as Group ____
Answer- H-5

Buildings and structures that contain materials that are health hazards shall be
classified as Group ____ where the amounts exceed the maximum allowable quantities.
Answer- H-4

Buildings or structures that contain materials that readily support combustion or present
a physical hazard shall be classified as Group ____ Answer- H-3

Buildings and structures that contain materials that present a deflagration hazard or a
hazard from accelerated burning shall be classified as Group ____ Answer- H-2

A Group I-1 assisted living facility where the care recipients may require limited verbal
or physical assistance during egress activities is considered condition ____ Answer- 2

Hospitals, nursing homes and similar medical care facilities shall be classified as Group
_____ occupancies. Answer- I-2

Nursing homes are considered to be Group I-2, Condition ____ occupancies. Answer-
1

A Group I-3 occupancy shall include buildings that are inhabited by more than ____
persons who are under restraint or security. Answer- five (5)

Rooms and spaces within places of religious worship providing custodial care during
religious functions shall be classified as ____ , ____ , ____ , ____ , ____ . Answer- part
of the primary occupancy

Motor fuel-dispensing facilities and department stores are examples of Group ____
occupancies. Answer- M

,Owner occupied lodging houses with ____ or fewer guest rooms and ____ or fewer total
occupants are permitted to be constructed in accordance with the International
Residential Code. Answer- five (5), ten (10)

Transient hotels and motels are examples of Group ____ occupancies. Answer- R-1

A room used for storage purposes that is ____ to another occupancy shall be classified
as part of that occupancy. Answer- accessory

Apartment houses are considered Group ____ occupancies. Answer- R-2

Facilities for more than five but not more than 16 occupants, excluding staff, who reside
on a 24-hour basis in a residential environment and receive custodial care are Group
____ occupancies. Answer- R-4

Nontransient congregate living facilities with ____ or fewer occupants are classified as
Group R-3 occupancies. Answer- 16

Buildings used for storage that are not classified as a hazardous occupancy are
classified as Group ____. Answer- S

Barns, private garages, tanks, and towers are all examples of Group _____
occupances. Answer- U

In a covered mall building, a fire-resistance-rated separation is not required between
_________ and the mall. Answer- tenant spaces

In determining required means of egress of the mall in a covered mall building,
occupant load factor (OLF) is not required to be less than ____ and shall not exceed
____ Answer- 30, 50.

When a tenant space in an open or covered mall building has an occupant load of ____
or more, not less than two means of egress shall be provided. Answer- 50

The maximum distance of travel from any point within a mall or a covered mall building
to an exit shall not exceed ____ feet. Answer- 200

In a covered mall building, the minimum width of an exit passageway or corridor from a
mall shall be ____ inches. Answer- 66

The aggregate clear egress width of the mall in either a covered or open mall building
shall be not less than _____ feet. Answer- 20

Within each individual tenant space in a covered or open mall building, the distance of
travel from any point to an exit or entrance to the mall shall be not greater than ____
feet. Answer- 200

, Covered mall buildings exceeding ____ square feet shall be provided with emergency
power systems that are capable of operating the emergency voice/alarm communication
system. Answer- 50,000

In a high-rise building, every required interior exit stairway serving floors more than 75
feet above the lowest level of fire department vehicle access shall be a ___ ___.
Answer- smoke-proof enclosure.

In high-rise buildings, electrically powered fire pumps are classified as ___ power loads.
Answer- emergency

Atrium spaces shall be separated from adjacent spaces by a ____ -hour fire barrier.
Answer- 1

The provisions of Section 405 Underground Buildings apply to building spaces having a
floor level used for human occupancy more than ____ feet below the finished floor of
the lowest level of exit discharge. Answer- 30

A building having a floor level more than ____ feet below the finished floor of the lowest
level of exit discharge shall be divided into a minimum of two compartments of
approximately equal size. Answer- 60

Carports open on fewer than two sides shall be considered to be a ____ Answer-
garage

Repair garage floors shall be of ____ or similar non-combustible and nonabsorbent
materials Answer- concrete

Repair garages shall be _____ ventilated in accordance with the International
Mechanical Code Answer- mechanically ventilated

Motor vehicle service station canopies under which fuels are dispensed shall have a
clear, unobstructed height of not less than ____ ____ to the lowest projecting element in
the vehicle drive-through area. Answer- 13 feet 6 inches

Openings from a parking garage directly into a room used for ____ ____ shall not be
permitted Answer- sleeping purposes

In public parking garages, vehicle barriers, where required, must be a minimum of ____
____ in height. Answer- 2 feet 9 inches

In public parking garages, the clear height of each floor level in vehicle and pedestrian
traffic areas shall be not less than ____ feet. Answer- 7

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Wiseman. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €9,38. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 72042 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€9,38  2x  verkocht
  • (0)
  Kopen