100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
Eerder door jou gezocht
Backflow prevention assembly tester practice exam 175 questions and answers 2024 Double Check Valve Assembly - ANSW..Does not prevent against contaminant, but does prevent against backsiphonage, backpressure, and pollutants€17,03
In winkelwagen
Backflow prevention assembly tester practice exam 175 questions and answers 2024 Double Check Valve Assembly - ANSW..Does not prevent against contaminant, but does prevent against backsiphonage, backpressure, and pollutants
13 keer bekeken 0 keer verkocht
Vak
Backflow prevention assembly
Instelling
Backflow Prevention Assembly
Backflow prevention assembly tester practice exam
175 questions and answers 2024
Double Check Valve Assembly - ANSW..Does not prevent against contaminant,
but does prevent against backsiphonage, backpressure, and pollutants
Backflow prevention assembly tester practice exam
175 questions and answers 2024
Double Check Valve Assembly - ✔✔ANSW✔✔..Does not prevent against contaminant,
but does prevent against backsiphonage, backpressure, and pollutants
Proper installation for DC and RP - ✔✔ANSW✔✔..Minimum 12" above grade, maximum
36" above grade, accessibility for testing and repair, and weather/vandalism protection
(if needed) with adequate drainage.
Proper installation for DC and RP - ✔✔ANSW✔✔..Double check valve assemblies and
reduce pressure backflow preventers should be installed vertically, if they have been
specifically approved for vertical orientation.
Pressure Vacuum Breaker (PVB) - ✔✔ANSW✔✔..Does not protect against
backpressure, but will protect against backsiphonage, contaminants, and pollutants.
Atmospheric Vacuum Breaker (AVB) - ✔✔ANSW✔✔..Does not protect against
backpressure, but will protect against backsiphonage, contaminants, and pollutants.
Atmospheric Vacuum Breaker (AVB) - ✔✔ANSW✔✔..Must be 6" above grade and has
intermittent (non-continuous use)
Indirect or direct - ✔✔ANSW✔✔..What kind of Cross connection is it?
Pollutant or contaminant - ✔✔ANSW✔✔..What is the degree of hazard?
Water supply protection - ✔✔ANSW✔✔..The supply line and fittings for every plumbing
fixture shall be protected so as to prevent backflow.
Dual Check valve type backflow preventer - ✔✔ANSW✔✔..Non testable
Barometric Loop - ✔✔ANSW✔✔..Shall proceed the point of connection and shall
extend vertically to a height of 35 feet. This shall only be utilized as an atmospheric-type
or pressure-type vacuum breaker.
Backflow test gages - ✔✔ANSW✔✔..Include three detachable color coded hoses.
High pressure: red
, Low pressure: green or blue
Bypsss/vent: typically black or yellow
Backflow test gages - ✔✔ANSW✔✔..They are tested periodically (minimum of annually)
using pressure differential gages.
Backflow test gages - ✔✔ANSW✔✔..Should be looked at a minimum of annually.
Local administrators will require and annual inspection and a copy of the certification
and paperwork.
Kit supposed to be accurate within + - 0.2 PSID at several different readings.
Air Gap - ✔✔ANSW✔✔..A physical seperation between the free flowing discharge end
of a potable water supply pipeline and the highest flood level of an open or non-
pressure receiving vessel.
Air Gap - ✔✔ANSW✔✔..Requires a minimum vertical air space 2 pipe diameters above
the flood rim.
Salmonellosis - ✔✔ANSW✔✔..A disease caused by pathogenic bacterica (often
associated with chicken), which affects the intestinal tract. The primary symptom is
severe diarrhea.
A valve designed to open in the direction of normal flow and close with the reversal of
flow. - ✔✔ANSW✔✔..Check valve
Overflow level - ✔✔ANSW✔✔..The maximum height that water or liquid will rise in a
receptacle before it flows over the rim.
Backflow - ✔✔ANSW✔✔..A hydraulic condition, caused by a difference in pressures, in
which non-potable water or other fluids flow into a potable water system.
RPBP - ✔✔ANSW✔✔..A shortened name for a reduced pressure backflow preventer
Air Gap - ✔✔ANSW✔✔..In plumbing, the unobstructed vertical distance through the free
atmosphere between the lowest opening from any pipe or outlet supplying water to a
tank, plumbing fixture, or other container, and the overflow rim of that container
potential cross connection - ✔✔ANSW✔✔..Any arrangements of pipes, fittings, or
devices that indirectly connects a potable water supply to a non-potable source
Dysentery - ✔✔ANSW✔✔..A disease (sometime waterborne) caused by pathogenic
microorganisms and characterized by severe diarrhea with passage of mucus and blood
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Bestnursesteve. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €17,03. Je zit daarna nergens aan vast.