A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose limits for the spinal cord, you could: a. use high energy photon beams to decrease the entrance dose. b. block the spinal cord out of all treatment fields €10,26   In winkelwagen

Tentamen (uitwerkingen)

A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose limits for the spinal cord, you could: a. use high energy photon beams to decrease the entrance dose. b. block the spinal cord out of all treatment fields

 6 keer bekeken  0 keer verkocht
  • Vak
  • MDCB
  • Instelling
  • MDCB

A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable dose limits for the spinal cord, you could: a. use high energy photon beams to decrease the entrance dose. b. block the spinal cord out of all treatment fields after 40 Gy is delivered. c. use a BID t...

[Meer zien]

Voorbeeld 2 van de 11  pagina's

  • 6 september 2024
  • 11
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • MDCB
  • MDCB
avatar-seller
MDCB practice questions need extra
review





A patient is to receive 55 Gy to a tumor in the mediastinum. In order to meet the acceptable
dose limits for the spinal cord, you could:
a. use high energy photon beams to decrease the entrance dose.
b. block the spinal cord out of all treatment fields after 40 Gy is delivered.
c. use a BID treatment technique to achieve greater repair time for the normal tissue cells.
d. utilize a 3DCRT beam arrangement including oblique beam angles. - ANS d. utilize a
3DCRT beam arrangement including oblique beam angles.

Which of the following statements are true for Iodine-125?
a. half-life 86.4 days.
b. has life-long radiation protection issues.
c. energy of 0.412 MeV.
d. decays exclusively by electron capture. - ANS d. decays exclusively by electron capture.

The most significant effect(s) of an air cavity in a megavoltage beam treatment is:
a. a change in the spectral energy distribution within the cavity.
b. an increased primary photon transmission through the cavity.
c. an enhanced absorption of dose in and beyond the cavity.
d. a partial gain of electronic equilibrium at the cavity interface. - ANS b. an increased
primary photon transmission through the cavity.

For patients with limited life expectancy the common dose fractionation for cord compression is:
a. 800cGy in 1 fraction.
b. 2000cGy in 5 fractions.
c. 3000cGy in 10 fractions.
d. 3750cGy in 15 fractions. - ANS a. 800cGy in 1 fraction.

Mayneord F factor corrects PDD for:
a. heterogeneity.
b. scatter.
c. Inverse square.
d. exponential attenuation. - ANS b. Inverse square- does not correct for scatter

For quality assurance of brachytherapy treatment planning computers, the dose rates should
agree with published data tables to which of the following degrees?
a. +- 1%

, b. +- 2%
c. +- 3%
d. +- 5% - ANS b. +- 2%

The expected accuracy of treatment planning systems that perform brachytherapy dose
calculations should be within: a. +/- 3%
b. +/- 5%
c. +/- 7%
d. +/- 10% - ANS b. +/- 5%

With LINAC based SBRT/SABR and a plan that has a 100% maximum IDL, what is the typical
range of prescription isodose line covering the PTV?
a. 40 - 60 %
b. 60 - 90 %
c. 90 - 100 %
d. > 100 % - ANS c. 90 - 100 %

The ratio of the dose rate of a given field size to the dose rate of the reference field size is:
a. Relative output factor
b. Back scatter factor
c. Percent depth dose
d. Tissue maximum ratio - ANS A. Relative output factor

During which stage of mitosis do the chromosomes align across the equator of the spindle
fibers?
a. prophase
b. metaphase
c. anaphase
d. telophase - ANS b. metaphase

Which of the following is true regarding clinical electron beams?
a. High energy electrons lose energy at a rate of approximately 2 MeV per cm of water or soft
tissue.
b. The depth of the 80% isodose occurs at approximately 1/4 of the electron energy in MeV.
c. The depth of the 90% isodose occurs at approximately 1/3 of the electron energy in MeV.
d. The practical range of electrons (in cm of water) is approximately 2 times the energy in MeV. -
ANS d. The practical range of electrons (in cm of water) is approximately 2 times the
energy in MeV.

What factors are instrumental in determining the dose uniformity in equally weighted parallel
opposed beams?
a. beam energy, tissue inhomogeneity and patient thickness
b. beam energy, patient thickness and tissue maximum ratio
c. beam flatness, patient thickness and collimator scatter

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

Verzekerd van kwaliteit door reviews

Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper DocLaura. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €10,26. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 83637 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen

Laatst bekeken door jou


€10,26
  • (0)
  Kopen