1625 yr - ANS Ra-226 half life
3.8 d - ANS Rn-222 half life
5.3y - ANS Co-60 half life
30y - ANS Cs-137 half life
74 d - ANS Ir-192 hald life
27 d - ANS Au-198 half life
60d - ANS I-125 half lfie
17d - ANS Pd-103 h...
Co-60, Teletherapy, GammaKnife, HDR, Prostate Seed Implant - ANS List in order amount
of activity from highest to lowest:
HDR, Co-60, Teletherapy, GammaKnife, Prostate Seed Implant
RX isodose Volume/PTV Volume - ANS Conformity Index
<10% - ANS Heart V25
D2 - ANS Maximum total dose in Gy to any point 2cm or greater away from the PTV in any
direction
V12<5-10cc - ANS Brain volume SRS 1 fx
2mm; 1 degree - ANS TG-142 suggests monthly QA tolerances for lateral, longitudinal, and
rotational couch positions for IMRT to be
2mm, 1% on a side - ANS TG-142 suggests monthly QA tolerances for mechanical/light
field coincidence for IMRT to be
2% - ANS TG-142 suggests monthly QA tolerances for electron output constancy for IMRT
to be
R50 - ANS the ratio of the volume of 50% of the prescription dose isodose to the volume of
the PTV
2mm - ANS TG-40 suggests daily QA tolerances for laser localization for simulators to be
2mm - ANS TG-40 suggests annual QA for medical accelerator tolerances for gantry
rotation isocenter to be
<32% - ANS Kidney V20
E, FS, d, SSD - ANS PDD is dependent on
E, FS, d - ANS TMR is dependent on
, 3.7 x 10^10 Bq - ANS 1 Ci =? Bq
10^6 - ANS mega (M)
alpha particle, 1MV, 250kVp, Co-60 - ANS Rank LET from highest to lowest: 1MV, alpha
particle, 250kVp, Co-60
1mSv - ANS 100mrad = ? dose equivalent
<12 Gy - ANS Optic Nerve/Chiasm SRS 1 fx Dmax
target, Primary collimator, flattening filter, dose chambers, secondary collimator - ANS
What is the correct order of components in treatment head to generate x-rays?
6Mv - ANS Which linac energy requires the highest beam current
Leukemia - ANS Which is considered a stochastic effect?
Cataracts, Erythema, Sterility, Leukemia
Slightly greater - ANS The lateral penumbra of a proton field is ______ as compared to a
photon field.
55Gy - ANS What is the ideal dose limit to 0.03cc of the brainstem?
Depth, FS, E - ANS TMR are dependent on what?
Dscatter/Dair under SAD conditions - ANS SAR is defined by
the pelvic sidewall/obturator nodes - ANS The location of point B in a T&O procedure is
(273.2 + T / 295)(760/P) - ANS Temp/Press correction formula
slightly greater - ANS The surface dose for a proton field is _______ as compared to a
photon field.
Linac QA - ANS TG142 is a document that gives recommendations on what?
Prostate - ANS Cs-131 is mostly common used in brachytherapy for which kind of
treatment?
1 - ANS The QF for electron is:
a portion of the target is not covered by the RX dose - ANS A Conformity Index of <1.0
means what?
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper DocLaura. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €10,01. Je zit daarna nergens aan vast.