ARTHROPLASTY IOT EXAM | ARTHROPLASTY
OA EXAM | ALL QUESTIONS AND CORRECT
ANSWERS | GRADED A+ | LATEST VERSION |
VERIFIED ANSWERS
What is the name of the website where all of management of the Virtual
Implant Positioning™ (VIP) system occurs?
- Vip.Arthrex.com
- Arthrexvip.com
- MyVip.com
- Arthrex.VIPplan.com ------CORRECT ANSWER---------------Arthrexvip.com
All of the following are mandatory information for a new Virtual Implant
Positioning™ (VIP) case EXCEPT:
- Side (side of surgery i.e. left or right shoulder)
- Date of CT scan
- Proposed procedure (i.e. anatomic or reverse total shoulder arthroplasty
- Pt. Name ------CORRECT ANSWER---------------Date of CT scan
True or False: Prior to uploading to Virtual Implant Positioning™ (VIP), CT
scans must be compressed.
- True
- False ------CORRECT ANSWER---------------True
Which of the "legs" of the Virtual Implant Positioning™ (VIP) targeter
overhang the glenoid surface?
- The anterior and posterior-inferior
- The anterior-superior and posterior-superior
- The anterior-superior and anterior-inferior
- The posterior and anterior-inferior ------CORRECT ANSWER---------------
The anterior-superior and anterior-inferior
,What is the turnaround time to receive the Glenoid Targeter coordinates
after approval of the Virtual Implant Positioning™ (VIP) Plan?
- Immediate
- 48 hours
- 3-5 business days
- 10 business days ------CORRECT ANSWER---------------48 hours
Which two surfaces is the CA (cuff arthropathy) humeral heads designed to
articulate with?
- Humerus and glenoid
- Glenoid and rotator cuff
- Acromion and coracoid
- Glenoid and acromion ------CORRECT ANSWER---------------Glenoid and
acromion
Why would a CA humeral head be indicated instead of a Univers Revers™
total shoulder arthroplasty?
- Deltoid insufficiency
- Intact rotator cuff
- Active infection
- Advanced patient age ------CORRECT ANSWER---------------Deltoid
insufficiency
Wollf's law regarding bone states:
- Increased stress on bone leads to weaking of bone
- Changes in stress lead to adaptation in bone
- Decreased stress on bone leads to strengthening of bone
- Increased bone stress leads to osteopenia ------CORRECT ANSWER------
---------Changes in stress lead to adaptation in bone
,Which patient would NOT be a good candidate for percutaneous pinning of
a proximal humeral fracture?
- Patient with a 2-part fracture
- Patient with a 3-part fracture
- Patient with a low likelihood for AVN
- Patient with a high likelihood for AVN ------CORRECT ANSWER-------------
--Patient with a high likelihood for AVN
The adjustable height of the Arthrex Univers™ shoulder fracture system
stem is best described as providing:
- Up to +7.5 mm of adjustable height
- Up to -7.5 mm of adjustable height
- + or - 7.5 mm of adjustable height
- + or - 15 mm of adjustable height ------CORRECT ANSWER---------------+
or - 7.5 mm of adjustable height
Preparation of the humeral canal for the Univers™ shoulder fracture
system stem includes:
- Reaming to size and implantation of the stem
- Reaming to size then broaching to size before implantation of the stem
- Reaming to size and then broaching one size under before implantation of
the stem
- Reaming to size and broaching to one size over before implantation of the
stem ------CORRECT ANSWER---------------Reaming to size and
implantation of the stem
When cementing the Univers™ shoulder fracture system stem, which
statement is correct?
- After reaming, the stem is up-sized by 1 before implantation
- The humerus is reamed line to line with the size of stem to be implanted
- After reaming, the stem is down-sized by 1 before implantation
, - The Universe shoulder fracture system stem is not indicated for cemented
implantation ------CORRECT ANSWER---------------After reaming, the stem
is down-sized by 1 before implantation
How much variable angulation for screw placement is provided by the
locking bushings in the Arthrex Proximal Humeral Fracture SuturePlate™?
- 15 degrees
- 20 degrees
- 45 degrees
- 60 degrees ------CORRECT ANSWER---------------60 degrees
When using a 36mm SutureCup and Insert, what glenosphere options are
approved for use?
a) 42 + 4
b) 36 standard
c) 39 + 2.5
d) 36 + 4
Both B & D
All of the above ------CORRECT ANSWER---------------Both B & D
The SutureCup is available in a posterior offset option, how many
millimeters is that offset?
- 1 mm
- 1.5 mm
- 2 mm
- 2.5 mm ------CORRECT ANSWER---------------2 mm
Which instrument is used to ensure proper morse taper engagement of the
Glenosphere in the Univers - Revers Universal Glenoid?
- Coring (peripheral) reamer
- Central screw depth gauge
- Glenosphere forceps
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper StudyWay. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €25,31. Je zit daarna nergens aan vast.